    Kane 251 Combustion Flue Gas Analyser Kit

    Complete with an infrared printer and carry case, the Kane 251 Combustion Flue Gas Analyser Kit is the perfect kit for engineers installing or servicing oil boilers, gas engineers or anyone working with Biomass appliances.

    Measuring CO2, CO and temperature and providing a range of calculated results, the KANE251 is a versatile instrument that boasts a higher range CO sensor (up to 10,000ppm) than it's sister model, the Kane 255, coming with a range of accessories including an infra-red linked printer, allowing test results to be quickly be printed on-site.

    Ideal for engineers who install and service oil/gas boilers or biomass appliances, the Kane 251 Combustion Flue Gas Analyser Kit is an incredibly versatile and cost-effective bundle.

    The Kane 251 is also available as the KANE251NO, with this optional upgrade offering the measurement of Nitric Oxide (NO) as well as all standard features.

  • Specification

    Flue Temperature

    • Range: 0-600°C
    • Resolution: 0.1°C
    • Accuracy: ±2°C, ±0.3% reading

    Inlet Temperature (Internal Sensor)

    • Range: 0-50°C
    • Resolution: 0.1°C
    • Accuracy: ±1°C, ±0.3% reading

    Inlet Temperature (External Sensor)

    • Range: 0-600°C
    • Resolution: 0.1°C
    • Accuracy: ±2°C, ±0.3% reading

    Oxygen (Using dry gases at STP)

    • Range: 0.21%
    • Resolution: 0.1%
    • Accuracy: ±0.3%

    Carbon Monoxide (H2 compensated)

    • Range: 0-20ppm, 21-4,000ppm nom, 4,001ppm-10,000ppm max, 20,000pm max for 15 mins
    • Resolution: 1ppm
    • Accuracy: ±3ppm, ±5% of reading, ±10% of reading

    Carbon Dioxide (Using dry gases at STP)

    • Range: 0-20%
    • Resolution: 0.1%
    • Accuracy: ±0.3% volume

    Calculated Efficiency (Net or Gross)

    • Range: 0-99.9%
    • Resolution: 0.1%
    • Accuracy: ±1.0% reading

    Calculated Efficiency High (C)

    • Range: 0-119.9%
    • Resolution: 0.1%
    • Accuracy: ±1.0% reading

    Calculated Excess Air

    • Range: 0-250%
    • Resolution: 0.1%
    • Accuracy: ±0.2% reading

    Calculated CO/CO2 ratio

    • Range: 0-0.999
    • Resolution: 0.0001
    • Accuracy: ±5% reading

    Nitric Oxide Low Range (NO model only)

    • Range: 1ppm
    • Resolution: ±2ppm < 30ppm (using dry gases at STP), ±5ppm > 30ppm
    • Accuracy: 0 to 100ppm

    Nitric Oxide High Range (NO model only)

    • Range: 1ppm
    • Resolution: ±5ppm < 100ppm (using dry gases at STP), ±5% reading > 100ppm
    • Accuracy: 0-1000ppm

    General

    • Pre-programme fuels: Natural gas, Light Oil, Propane, Butane, LPG, Wood Pellets.
    • Weight: 1kg / 2.2lb
    • Handset Dimensions: 200mm / 7.9" x 45mm / 1.8" x 90mm / 3.5"
    • Probe Dimensions: L300mm / 11.8" x Dia 6mm / 0.25" with 200mm / 7.8" long stainless steel shaft, type K thermocouple and 3m / 6ft long neoprene hose
    • Ambient Operating Range: ±0°C to ±40°C / 32-104°F, 10% to 90% RH non-condensing
    • Storage Capacity: 20 sets of test results in volatile memory
    • Battery Life: 4AA cells > 8 hours using Alkaline AA cells
    • Charger (optional): 110Vac/220 Vac nominal for NMiH batteries only, 12V in vehicle charger for NMiH batteries only
  • Supplied Accessories

    • Kane 251 Combustion Flue Gas Analyser
    • Charger
    • Batteries
    • KMCP2
    • Test report
    • Manual
    • KANE IRP-2
    • Case
  • Product Questions

    Please Sign in or Create an account to post a question.

    There are no entries.

  • Reviews

    There are currently no reviews for this product. If you have previously purchased it please leave a review using our quick and easy form to the right.

    Write Your Own Review

    Only registered users can write reviews. Please, log in or register

  • Delivery Information

    At Test-Meter.co.uk we understand the importance of a reliable delivery service when shopping online. Especially when the goods are often essential to your working day. If your goods are required by a certain date please feel free to contact us for an honest and realistic indication whether this can be met.

    We use DPD/Interlink for all larger items and Royal Mail for smaller items and accessories. With DPD/Interlink you will receive a 1 hour delivery window on the day of delivery via e-mail/text so you will not have to wait around all day. We also offer delivery options for goods required urgently on certain products, all which are sent by DPD/Interlink on a fully traceable and manageable service.

    Our charges for UK deliveries:

    • FREE Delivery (on select products only): typically 2-5 working days*
    • Standard Delivery at £4.95: 2-3 working days
    • Next Working Day Delivery (on select products only) at £8.95
    • Pre 10.30am Next Working Day Delivery (on select products only) at £19.95*
    • Saturday Pre 12pm Delivery (on select products only) at £19.95*
    • Sunday Pre 12pm Delivery (on select products only) at £19.95*

    *UK mainland only

    NOTE! For next working day or Saturday delivery options the order MUST be placed no later than 3pm on the working day before delivery is required. After 3pm, please arrange with our staff before selecting a priority delivery service. Priority services are available to UK mainland residents only.

    Customers outside the UK:

    Test-Meter.co.uk exports to many countries all over the world. Prices for shipping vary on location and weight/dimensions. Costs are calculated for certain countries at the checkout. If your country is not included in this list please e-mail admin@test-meter.co.uk with your name, address and the items you would like to order for an accurate shipping quote.