Kane 255 Oil Fired Combustion Analyser Kit

SKU: KANE255OILKIT
  • Tailored for the servicing, commissioning and maintaining oil-fired appliances
  • Includes KANEMSP smoke pump, compound pressure & vacuum gauge and more
  • Suitable for appliances burning natural gas, propane, butane, LPG or light oils
More Info
£693.60 £578.00
Discontinued

Kane 255 Oil Fired Combustion Analyser Kit

This product has now been discontinued. The closest replacement to this kit is the Kane 458s Flue Gas Analyser Oil Kit.

Tailored for servicing, commissioning and maintaining oil-fired appliances, the Kane 255 Oil Fired Combustion Analyser Kit is the ideal kit for measuring any appliance burning natural gas, propane, butane, LPG or light oils.

Accurately measuring O2, CO and temperature, the KANE255 can calculate CO2, CO/CO2 ratio and efficiency as well as being suitable to check CO levels in a room.

The Kane 255 Oil Fired Combustion Analyser Kit comes complete with a KANEMSP smoke pump, compound pressure and vacuum gauge, oil pressure gauges and high pressure hoses, in addition to all the accessories from the base set (including KMIRP infrared printer, protective rubber casing and carry case), making it the perfect kit for anyone undertaking regular gas analysis.

Key Features

  • Kit tailored for the servicing, commissioning and maintaining oil-fired appliances
  • Multi-fuel: Suitable for appliances burning natural gas, propane, butane, LPG or light oils
  • Variety of measurements: O2, CO and temperature measurements, calculates CO2, CO/CO2 ration and efficiency, room CO tests
  • Low cost ownership with six-year extended warranty (when serviced annually by Kane)
  • Features KANEMSP smoke pump, compound pressure & vacuum gauge, oil pressure gauges and high pressure hoses, KMIRP infrared printer, protective rubber casing and carry case

What's In The Box?

  • KANE 255 Combustion Flue Gas Analyser
  • Batteries
  • KMCP2
  • Test report
  • Manual
  • KANE IRP-2
  • KANE MSP manual smoke pump
  • 0-300 psi pressure gauge
  • Pressure gauge manifold
  • Compound gauge (pressure and vacuum)
  • High pressure hose and 2 adaptors
  • Large carry case
Specification

Flue Temperature

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Inlet Temperature (Internal Sensor)

  • Range: 0-50°C
  • Resolution: 0.1°C
  • Accuracy: ±1°C, ±0.3% reading

Inlet Temperature (External Sensor)

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Oxygen (Using dry gases at STP)

  • Range: 0.21%
  • Resolution: 0.1%
  • Accuracy: ±0.3%

Carbon Monoxide (H2 compensated)

  • Range: 0-20ppm (1), 21-2,000ppm nom (2) and 4,000ppm max for 15 mins (3)
  • Resolution: 1ppm
  • Accuracy: ±0.3ppm (1), ±3ppm (2) and ±5% of reading (3)

Carbon Dioxide (Using dry gases at STP)

  • Range: 0-20%
  • Resolution: 0.1%
  • Accuracy: ±0.3% volume

Calculated Efficiency (Net or Gross)

  • Range: 0-99.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Efficiency High (C)

  • Range: 0-119.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Excess Air

  • Range: 0-250%
  • Resolution: 0.1%
  • Accuracy: ±0.2% reading

Calculated CO/CO2 ratio

  • Range: 0-0.999
  • Resolution: 0.0001
  • Accuracy: ±5% reading

General

  • Pre-programme fuels: Natural gas, Light Oil, Propane, Butane, LPG, Wood Pellets.
  • Weight: 1kg / 2.2lb
  • Handset Dimensions: 200mm / 7.9" x 45mm / 1.8" x 90mm / 3.5"
  • Probe Dimensions: L300mm / 11.8" x Dia 6mm / 0.25" with 200mm / 7.8" long stainless steel shaft, type K thermocouple and 3m / 6ft long neoprene hose
  • Ambient Operating Range: ±0°C to ±40°C / 32-104°F, 10% to 90% RH non-condensing
  • Storage Capacity: 20 sets of test results in volatile memory
  • Battery Life: 4AA cells > 8 hours using Alkaline AA cells
  • Charger (optional): 110Vac/220 Vac nominal for NMiH batteries only, 12V in vehicle charger for NMiH batteries only