Megger DET4TC2 Earth Testing Kit with Clamps

SKU: MEGGDET4TC2CLAMPS
  • Megger DET4TC2 Earth Tester with advanced ground-testing capabilities
  • ICLAMP allows attached rod technique for electrode testing without disconnection
  • VCLAMP for stake-less testing in conditions unsuited to driving in stakes
More Info
In Stock - Available Next Day

Megger DET4TC2 Earth Testing Kit with Clamps

The Megger DET4TC2 Earth Testing Kit with Clamps uses the Megger DET4TC2 Digital Earth Tester as its base device. It can perform an array of functions for ground testing including two, three-, and four-pole testing, leakage current, and ground-voltage measurement whilst advanced interference cancelling permits accurate readings in noisy environments. Its IP54 weatherproof rating, simple operation, and backlit screen make it a superb instrument in the outdoor conditions associated with ground-testing.

The Megger DET4TC2 Clamp Kit contains an ICLAMP which allows the tester to take measurements using attached rod technique (ART). This means that the user can perform electrode testing without disconnection and also measure leakage currents as low as 1mA. The other clamp, the VCLAMP, allows stake-less testing for when conditions are not suited to driving in stakes.

Overall, the Megger DET4TC2 Clamp Kit uses an excellent base instrument with extremely accurate measurement functions and provides clamps which add two very useful extra capabilities. The kit also includes a calibration field check list, a stake and wire set, a hard carry case, and a calibration certificate. For increased capabilities, you may wish to consider the Megger DET4TC2 Professional Earth Testing Kit.

Megger part number: 1000-365

Key Features

  • Megger DET4TC2 Digital Earth Tester
  • ICLAMP for ART testing
  • VCLAMP for stake-less testing
  • Two-, three- and four-pole testing
  • Resistance range of 0.01Ω to 200kΩ
  • Ground voltage range of 1V to 100V
  • Current range from 1mA to 20A
  • Noise cancellation up to 40V peak to peak

What's In The Box?

  • Megger DET4TC2 Earth Tester
  • Standard hard carry case
  • Standard stake and wire kit (15m, 10m, 10m, 3m)
  • ICLAMP for ART testing
  • VCLAMP for stake-less testing
  • Field calibration check for instrument and clamps
  • Right angle terminal adaptors for connecting bare wires to terminals
  • Calibration certificate
Specification
  • Ingress protection: IP54
  • C stake, P stake and Noise check: Automatic
  • Noise rejection: 40 V pk to pk
  • 2-wire, 3-wire, 4-wire test: Yes, no shorting links required
  • No disconnect testing (ART): Yes, with ICLAMP
  • Stakeless measurement: Yes, with ICLAMP and VCLAMP

Instrument output

  • Voltage: ±25 V or ±50 V at 94 Hz, 105 Hz, 111 Hz and 128 Hz
  • Current: 4.5 mA or 0.45 mA or 0.045 mA
  • Ground current range with clamp: 0.5 mA to 19.9 A
  • Ground current accuracy: 5% ±3 digits
  • Ground voltage range: 0 to 100 V ac
  • Ground voltage accuracy: 2% ±2 V

Resistance ranges

  • 2, 3, 4 pole: 0.01 Ω to 200 kΩ
  • ART: 0.01 Ω to 200 kΩ
  • Stakeless: 0.01 Ω to 200 Ω

Resistance accuracy

  • 2P measurements: 2% ±3 digits
  • 3P measurements: 2% ±3 digits
  • 4P measurements: 2% ±3 digits
  • ART measurements: 5% ±3 digits
  • Stakeless measurements: 7% ±3 digits

Maximum probe resistance

  • Rp limit: 200 kΩ (50 V output voltage)
  • Rc limit: 200 kΩ (50 V output voltage)
  • Limits reduced to 100 kΩ for 25 V output voltage
  • Limits reduced to 5 kΩ for 0.01 Ω resolution
  • Display: 3.5” digit high contrast liquid crystal, backlit
  • Battery type: DET4TC2: 8 off AA (LR6) cells
  • Operating temperature range: -15 °C to +55 °C / 5 °F to 131 °F
  • Storage temperature range: -40 °C to +70 °C / -40 °F to 158 °F

Safety

  • Complies with the requirements of IEC61010-1 100V CAT IV between terminal pairs.*

EMC

  • In accordance with IEC61326-1

Standards Compliance

  • Complies with the requirements of KEMA K85B
  • Complies with the following parts of EN61557, “Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures”.
  • Part 1 - General requirements
  • Part 5 - Resistance to earth
  • Dimensions: 203 mm x 148 mm x 78 mm (8 in x 5.8 in x 3 in)
  • Weight: 1kg (2.2lb)

*The CAT IV 100 V rating is dependant on the use of a lead set of
at least this rating, for example the optional two wire lead set part
number 1001-858.