Product Features: Megger MIT430 Insulation and Continuity Teste
CATIV 600V applications
Insulation testing to 1000V and to 200GΩ
TRMS & DC Voltage measurement
Continuity testing at 200mA down to 0.01Ω#Analogue and dual digital display
Insulation & continuity limit alarms
PI/DAR and Timer function
Test result storage 
Bluetooth® wireless data transfer


The new Megger MIT400 series insulation and continuity testers has been designed for electrical testing by the utilities, industrial, commercial and domestic electricians. The wide range of features also makes the MIT400 series ideal for the maintenance and service/repair engineer. They replace the well-established BM400 insulation tester range, given greater functionality with simplified

Insulation Testing
 Test voltages - 250 V to 1000 V insulation test voltages available
Test Lock - Locks insulation test on continuously.
 The actual test voltage is displayed on the smaller digital readout.
The insulation result on the larger digital display.
Analogue arc display to replicate the response of a moving coil display. 
Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions
 Insulation testing from 10GΩ to 200GΩ
High quality flexible silicone test leads prevent measurement errors on higher GΩ ranges.
Test inhibit prevents testing if voltages in excess of 50 V are detected.
Insulation buzzer can be set to buzz if the insulation resistance is above a preset limit.

Continuity Testing
 Auto test on circuit contact.
 200mA or 20mA continuity test currents are available.
20 mA test current will considerably increase battery life.
 Lead resistance compensation (NULL) operates up to 9 Ω of resistance.
Buzzer ON-OFF selected by simple push button.
 Continuity buzzer limit alarm adjustable from 1 Ω to 20 Ω in 5 steps.

Analogue arc display
 Full display width analogue arc.
 Patented arc display shows charge and discharge characteristics not visible on a digital display.
 Single pointer “needle” response is similar to a moving coil meter.
 Logarithmic display for better low insulation value measurements.

Dual digital display
 Large main digital readout for good visibility of all main measurement results
 Second digital display for additional data such as:
     Insulation test voltage.
     Insulation leakage current.
     Supply frequency (when measuring volts).
     Test mode eg. PI, DAR or TI (Timed mode).

Storage & Downloading results
The MIT430 is capable of saving test results for recall to the screen. A simple storage structure allows for a test number and screen results to be recalled individually.
The MIT430 supports both test result storage and downloading. Test results can be stored in the instrument and subsequently downloaded to a computer with the Megger download manager software.
Data transfer is by Bluetooth, with the transmitter being enabled when the Download mode is selected on the instrument.
NOTE: The receiving PC needs to have Bluetooth capability or a USB port fitted a Bluetooth receiver. Class II (10m) is acceptable.

Safety
Designed to be exceptionally safe to use, fast detecting circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Specifically, all instruments:

Meet the international requirements of IEC1010-2 and EN61557.
 Live circuit detection inhibits insulation testing on circuits above 50 V.
 Live circuit detection and test inhibit on continuity measurements.
 Default display of live circuit voltage on all ranges.
 Detection and inhibit functions even if the protection fuse has failed.
 Suitable for use on CAT IV applications and supply voltages to 600 V.

Supplied Accessories: Megger MIT430 Insulation and Continuity Teste

 Red Lead 1.25m complete with probe 
 Black Lead 1.25m complete with probe
 Red Croc Clip
 Black Croc Clip
 Instrument Rubber Boot
 Calibration Certificate

Product Specifications: Megger MIT430 Insulation and Continuity Teste

Insulation
Nominal test voltages
MIT430 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation resistance range
MIT430 200 GΩ
Range Full Scale Accuracy
1000 volts ±3% ±2 digits ±0.2% per GΩ
500 volts. ±3% ±2 digits ±0.4% per GΩ
250 volts. ±3% ±2 digits ±0.8% per GΩ
Analogue range:
1 GΩ full scale
Short Circuit Current:
2 mA +0% -50%
Terminal voltage:
-0% +20% ±1 V
Test Current on load:
1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max.
EN61557 Operating range:
0,10 MΩ to 1,00 GΩ
Leakage Current:
10% ±3 digits
Voltage display:
3% ±3 digits ±0.5% of rated voltage
Polarisation Index (PI):
10 min / 1minute ratio
Dielectric Absorption Ratio (DAR):
60 sec / 30 sec ratio

Notes:
(1) All ranges measure from 0,00 MΩ upwards.
(2) Above specifications only apply when high quality silicone leads are being used.

Continuity
Measurement:
0,01 Ω to 99,9 Ω (0 to 100 Ω on analogue scale)
Accuracy:
±3% ±2 digits (0 to 100 Ω)
Open circuit voltage:
5 V ±1 V
Test current:
200 mA (–0 mA +20 mA) (0.01 Ω to 9.99 Ω)
20mA (±1 mA ) (10.0 Ω to 99.9 Ω)
Zero offset at probe tips:
0,10 Ω typical
Lead resistance zeroing:
Up to 9,00 Ω
Buzzer:
Variable limit 1 Ω, 2 Ω, 5 Ω, 10 Ω, 20 Ω

Resistance
Measurement:
0,01 kΩ to 1000 kΩ (0 to 1 MΩ on analogue scale)
Accuracy:
±3% ±2 digits
Open circuit voltage:
5 V ±1 V
Short circuit current:
20 μA ± 5 μA
Voltage range
0 to 600 V d.c. ±2% ±2 digits
10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
0 to 1000 V on Analogue scale
Unspecified input level 0 - 10 mV (40 to 400 Hz)
For non-sinusoidal waveforms additional specification apply:
±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter:
Operates at >25 V a.c. or d.c. on any range except OFF
Frequency:
40-450 Hz (40 Hz - 99,9 Hz)
±0.5% ±1 digit (100 Hz to 450 Hz)

Capacitance measurement
Measurement range: 100 pF to 10 μF
Accuracy: ± 5.0% ±2 digits Distance by capacitance:

Arithmetic conversion from capacitance measurement on
Default capacitance measurement: 50nF/m
Capacitance range: 40 nF/m to 60 nF/m
 

Result storage
Capacity: >1000 test results
Download: Bluetooth wireless
Bluetooth Class: Class II
Range: up to 10 m
 

Power Supply:
5 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used.
Battery life:
2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ

Dimensions
Instrument:
220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument + case:
456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)

Weight
Instrument only:
590 gms, 775 gms with boot (20.73 oz.(27.22 oz.)
Instrument plus case:
1.75kg (3.86 lb)

Fuse
Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.

Safety Protection
The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied

E.M.C.
In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient: <0,1% per °C up to 1 GΩ

Environmental
Operating range:
-10 to +55°C
Operating humidity:
90% RH at 40°C max.
Storage temperature range:
-25 to +70°C
Maximum altitude:
2000 m
Dust and water protection:
IP54 Protected against dust and splashing water

Recommended Accessories: Megger MIT430 Insulation and Continuity Teste

Submit Review

Please complete the information below and it will be displayed on our website once it has been reviewed by a member of staff.

Contribution type:

Rating:

Spambot:

Name:

Email: (Not displayed)

Review Title:

Review / Comment Details:



test-meter.co.uk - Home | Your Order | Latest Special Offers | Terms & Conditions | Contact Us | Request Link | Links | Site Map

Prices exclude delivery carriage at £10 and VAT at 20%

All brand names are trade marked to their respective owners.

Company Number: 5394680 VAT Number: GB 842 7016 40


test-meter.co.uk
is a trading name of PAT Training Services Limited.
PAT Training Services Limited.
1 Aston Court,
Town End Close,
LEEDS,
LS13 2AF
UK

Tel: 0113 248 9966
Fax: 0113 248 4276

admin@test-meter.co.uk

Copyright © PAT Training Services Limited, All rights reserved. E&OE