 T&R PCU2 mk5 Primary Current Injection Test System

T&R PCU2 mk5 Primary Current Injection Test System
Now £9275.00
Was £9960.00
Save £685.00
Buy Now
Upto 12kA primary current injection test set

More images...

Be the first to review this product!

Product Features: T&R PCU2 mk5 Primary Current Injection Test System

T&R PCU2 mk5 Primary Current Injection Test System

The PCU2 Mk5 Primary Current Injection System is suited to commissioning and maintenance testing where very high currents are required. The PCU2 is ideal for all primary current injection tasks including testing under and over current relays, circuit breakers and CT ratio testing. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry and is linked to the loading unit by control and metering cables. The control unit is designed to be used with one of two loading units that provide a maximum output current of either 5000A or 6000A for 5 minutes or up to 10kA or 12kA on an intermittent basis. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the LU6000 may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V.

The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. A flexible timing system is provided, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and overcurrent devices, reclosers, under and over voltage devices, current trips and circuit breakers. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current.

T and R PCU2 features
20kVA 5 minute output capability
Continuously variable output
Multi-function timing system
Digital true RMS memory ammeter
Bright LED displays
Automatic switch-off at end of test
Centralised control and metering
Separate control and loading units
Intermittent output up to 12kA
Continuous output up to 3kA
Low impedance, dual-range outputs

To purchase one of the necessary loading units please view either the LU5000 orLU6000 product pages.

Supplied Accessories: T&R PCU2 mk5 Primary Current Injection Test System

T&R PCU2 mk2 control unit
Spare fuse set
5m loading unit power interconnection lead
5m loading unit metering interconnection lead
2m mains lead
Operating manual

Product Specifications: T&R PCU2 mk5 Primary Current Injection Test System

Metering

    Parallel mode Series mode
Range 1 Full scale 5000A 2500A
  Resolution 1A 1A
  Accuracy 0.6% rdg+6d 0.6% rdg+6d
  Current trip 5500A 2750A
Range 2 Full scale 10kA 5kA
  Resolution 0.01kA 0.01kA
  Accuracy 0.6% rdg+6d 0.6% rdg+6d
  Current trip 11000A 5500A

Loading Unit Output (LU5000)

  Continuous 5mins on/
15mins off
5secs 1sec
  Current Max kVA Current Max kVA Current Max kVA Current Max kVA
Parallel
(0-4V)
2500A 10 5000A 20 8000A 32 10000A 40
Series
(0-8V)
1250A 10 2500A 20 4000A 32 5000A 40

Loading Unit Output (LU6000)

  Continuous 5mins on/
15mins off
5secs 1sec
  Current Max kVA Current Max kVA Current Max kVA Current Max kVA
Parallel
(0-3.3V)
3000A 10 6000A 20 9600A 32 12000A 40

Series
(0-6.6V)

1500A 10 3000A 20 4800A 32 6000A 40

Timer resolution: 1ms
Timer full scale: 999.999s
Timer accuracy: ±0.01%rdg+2d, ±0.01%rdg+3d current operated mode
Contact O/C voltage: 24V
Contact S/C current: 100mA
VDC input range: 24-240V DC
Supply requirements:  230V, 49-61Hz, 1ph, 23kVA for 5mins, 46kVA for 1 second
Storage temperature: -20°C to 60°C
Operating temperature: 0°C to 45°C
Dimensions (PCU2 only): 660 x 400 x 740mm
Weight (PCU2 only): 115kg

Recommended Accessories: T&R PCU2 mk5 Primary Current Injection Test System

Submit Review

Please complete the information below and it will be displayed on our website once it has been reviewed by a member of staff.

Contribution type:

Rating:

Spambot:

Name:

Email: (Not displayed)

Review Title:

Review / Comment Details:



test-meter.co.uk - Home | Your Order | Latest Special Offers | Terms & Conditions | Contact Us | Request Link | Links | Site Map

Prices exclude delivery carriage at £10 and VAT at 20%

All brand names are trade marked to their respective owners.

Company Number: 5394680 VAT Number: GB 842 7016 40


test-meter.co.uk
is a trading name of PAT Training Services Limited.
PAT Training Services Limited.
1 Aston Court,
Town End Close,
LEEDS,
LS13 2AF
UK

Tel: 0113 248 9966
Fax: 0113 248 4276

admin@test-meter.co.uk

Copyright © PAT Training Services Limited, All rights reserved. E&OE