Product Features: Seaward Primetest 250 PAT Tester

SEAWARD Primetest 250 PAT Tester

PAT Testing Pass and Fail Labels

The new Primetest 250 PAT tester will perform all tests required to comply with the IEE Code of Practice. These include RCD trip testing, protective conductor current and touch current testing. The Seaward Primetest 250 also carries out Insulation Testing at either 250V or 500V DC. The Seaward Prime test 250 is battery powered and can be plugged into the mains supply to run the protective conductor current and touch current tests.

As innovators within PAT, Seaward have also enabled the Seaward Primetest 250 to carry out full testing on 3-phase equipment found in factories, workshops, schools and colleges. The PT250 is the only tester on the current market that will test for Differential Leakage Current on 3-phase equipment using an optional Seaward 3-phase adaptor.

The battery powered Primetest 250 PAT tester is very easy to use with auto sequence test buttons and a large display with clear PASS/FAIL indication. This makes it an ideal choice of PAT tester for both novices to PAT testing or experienced test engineers who need to test a wide range of electrical equipment while fully complying the IEE guidelines. The Seaward Prmetest 250 is the next step in their already highly successful range of battery powered Primetest PAT testers, packing it with loads of features which will aid Electrical Safety within the workplace and help companies fully comply.

Seaward Primetest 250 Main Features:
►  
Fully complies with the IEE Code of Practice
►   RCD Trip Time Testing
►   Battery driven for mains free testing
►   Tests IEC leads including polarity check
►   Automatic Test Sequences
►   Hand held and Lightweight Appliance Safety Tester
►   Selectable 250V or 500V Insulation Test.
►   3-Phase Equipment testing (using optional adaptor)
►   Carries out Protective Conductor/Touch Current (using mains supply)
 
 

Supplied Accessories: Seaward Primetest 250 PAT Tester

► Seaward Primetest 250 PAT Tester
► Deluxe semi rigid carry case with zipped pouches
► Mains lead with 13A UK Plug for mains powered tests
► 230V Extension Lead Adaptor
► Test Lead with crocodile clip and mains lead
► Instruction manual
► 6 x AA Batteries
► FREE Roll of 500 Pass Labels
► FREE Roll of 200 Fail Labels
► FREE 100 PermaTAG Tough Cable Labels worth £39.00
► TEST-METER EXCLUSIVE: FREE PAT Testing Frequency & Test Limit Reference Guide
► 12 months manufacturers warranty

PAT Testing Pass and Fail Labels

Product Specifications: Seaward Primetest 250 PAT Tester

Earth continuity
Output Current: 200mA
Test Voltage (o/c): 9V DC nominal
Test Duration (Class I Test): 2s nominal
Display Range: 0.01 ohm to 19.99 ohm
Pass Value (Class I Test): 0.2O
Insulation resistance
Test Voltage: 250/500VDC @1mA nominal, < 2mA (s/c)
Test Duration (Class I or II): 2s
Display Range: 0.01 Mohm to 19.99 Mohm
Pass Value: 1.0 MO Class I
2.0 MO Class II
Equivalent leakage
Test Voltage: 40V Nominal AC 50Hz Open Circuit
Test Duration: 2s – 30s nominal
Display Range: 0.1 mA to 19.99mA
Pass Value: 0.75mA CLI / 0.25mA CL II
IEC lead test
Test voltage: 5V DC nominal
Test Duration: Time for test (2s max)
Test: Live / Neutral Checks for o/c, s/c and crossed
Protective Conductor Current
Test Voltage: Supply Voltage, max current 13A
Test Duration: 30s maximum
Display Range: 0.15 mA to 9.99 mA
Pass Value: 0.75mA/3.5mA (user selectable with 0.75mA as default)
Touch current
Test Voltage: Supply Voltage, max current 13A
Test Duration: 30s maximum
Display Range: 0.10 mA to 5.00 mA
Pass Value: 0.25mA

3 phase differential leakage current
***Requires 3 phase adaptor accessory ***
Test Voltage: 3 phase supply voltage
Test Duration: continuous measurement
Display Range: 0.10 mA to 9.99 mA
Pass Value: 3.5mA
RCD trip time
Test Voltage: Mains supply voltage
Test Current: 10mA / 30mA rms sinusoidal
Test Current Phase: 0°/180° auto switched on alternate tests
Measuring Range: 0ms – 500ms
Pass Value: 200ms

Power socket check
Input voltage range: 225 – 254V AC max current 13A UK
Indicates configuration of voltage potential: 
    Line potential phase to earth
    Line potential phase to neutral
    Line potential neutral to earth

Recommended Accessories: Seaward Primetest 250 PAT Tester

Submit Review

Please complete the information below and it will be displayed on our website once it has been reviewed by a member of staff.

Contribution type:

Rating:

Spambot:

Name:

Email: (Not displayed)

Review Title:

Review / Comment Details:



test-meter.co.uk - Home | Your Order | Latest Special Offers | Terms & Conditions | Contact Us | Request Link | Links | Site Map

Prices exclude delivery carriage at £10 and VAT at 20%

All brand names are trade marked to their respective owners.

Company Number: 5394680 VAT Number: GB 842 7016 40


test-meter.co.uk
is a trading name of PAT Training Services Limited.
PAT Training Services Limited.
1 Aston Court,
Town End Close,
LEEDS,
LS13 2AF
UK

Tel: 0113 248 9966
Fax: 0113 248 4276

admin@test-meter.co.uk

Copyright © PAT Training Services Limited, All rights reserved. E&OE