    Typical Applications:

    Features:

    • Measures AC/DC voltage to 1000V
    • Measures AC/DC current to 440mA
    • Measures resistance to 40MΩ
    • Measures frequency to 20kHz
    • Current sourcing and simulation from 0 to 20mA
    • HART mode and multiple step options

    The Fluke 789 Process Meter can measure a multitude of electrical parameters in addition to sourcing current in order to calibrate process loops. The meter boasts measurement for AC/DC voltage, AC/DC current, resistance, and frequency as well as continuity and diode testing. There is also a zero function, min/max/avg recording and display hold whist true RMS measurement helps safeguard accuracy on AC values.

    A 24V loop power supply allows a source current of between 0mA and 20mA to pass through resistances of up to 1200Ω and various ramp options include min/max toggling, auto-ramp, auto-step and four separate manual step options. The calibrator is also compatible with HART instruments.

    Part number: HPRO.3

  • Specification

    DC Voltage

    • Ranges: 4V / 40V / 400V / 1000V
    • Resolutions: 0.001V / 0.01V / 0.1V / 1V
    • Accuracy: 0.1% + 1 / 0.1% + 1 / 0.1% + 1 / 0.1% + 1

    DC Millivolts

    • Range: 400mV
    • Resolution: 0.1mV
    • Accuracy: 0.1% + 2

    AC Voltage

    • Ranges: 400mV / 4V / 40V / 400V / 1000V
    • Resolutions: 0.1mV / 0.001V / 0.01V / 0.1V / 1V
    • Accuracy (50Hz to 60Hz): 0.7% + 4 / 0.7% + 2 / 0.7% + 2 / 0.7% + 2 / 0.7% + 2
    • Accuracy (45Hz to 200Hz): 1.2% + 4 / 1.2% + 4 / 1.2% + 4 / 1.2% + 4 / 1.2% + 4
    • Accuracy (200Hz to 500Hz): 7% + 4 / 7% + 4 / 7% + 4 / 7% + 4 / 7% + 4

    AC Current

    • Range (45Hz to 2kHz): 0 to 1A*
    • Resolution: 0.001A
    • Accuracy: 1% + 2
    • Typical burden voltage: 1.5V/A

    *440mA continuous, 1A for 30s max

    DC Current

    • Ranges: 30mA / 1A*
    • Resolutions: 0.001mA / 0.001A
    • Accuracy: 0.05% + 2 / 0.2% + 2
    • Typical burden voltage: 14mV/mA / 1.5V/A

    *440mA continuous, 1A for 30s

    Resistance

    • Range: 400Ω / 4kΩ / 40kΩ / 400kΩ / 4MΩ / 40MΩ
    • Resolution: 0.1Ω / 0.001kΩ / 0.01kΩ / 0.1kΩ / 0.001MΩ / 0.01MΩ
    • Measurement current: 220µA / 60µA / 6µA / 600nA / 220nA / 22nA
    • Accuracy: 0.2% + 2 / 0.2% + 1 / 0.2% + 1 / 0.2% + 1 / 0.35% + 3 / 2.5% + 3

    Frequency Accuracy

    • Ranges: 199.99Hz / 1999.9Hz / 19.999kHz
    • Resolution: 0.01Hz / 0.1Hz / 0.001kHz
    • Accuracy: 0.005% + 1 / 0.005% + 1 / 0.005% + 1

    Frequency Sensitivity

    • Input range: 400mV / 4V / 40V / 400V / 1000V
    • Minimum sensitivity AC (RMS Sinewave) 5Hz to 5kHz: 150mV (50Hz to 5kHz) / 1V / 4V / 40V / 400V
    • Minimum sensitivity DC (RMS Sinewave) 5Hz to 5kHz: 150mV / 1V / 4V / 40V / 400V

    Diode Test and Continuity Test

    • Diode test indication: displays voltage drop acroos device 2.0V full scale; 0.2mA nominal test current at 0.6V; accuracy ±(2% + 1)
    • Continuity test indication: Continuous audible tone for test resistance <100Ω
    • Open circuit voltage: <2.9V
    • Short circuit current: 220µA typical
    • Overload protection: 1000V RMS
    Loop Power Supply
    • Voltage: 24V, short circuit protected

    DC Current Output

    Source mode

    • Span: 0mA or 4mA to 20mA, with overrange to 24mA
    • Accuracy: 0.05% of span
    • Compliance voltage: 28V with battery voltage >~4.5V

    Simulate Mode

    • Span: 0mA or 4mA to 20mA, with overrange to 24mA
    • Accuracy: 0.05% of span
    • Loop voltage: 24V nominal, 48V maximum, 15V minimum
    • Compliance voltage: 21V for 24V supply
    • Burden voltage: <3V

    General

    • Max voltage: 1000V
    • Batteries: 4 x 1.5V AA
    • Storage temperature: -40˚C to 60˚C
    • Operating temperature: -20˚C to 55˚C
    • Operating altitude: 2000m maximum
    • Temperature coefficient: 0.05 x specified accuracy per ˚C for temperatures <18˚C or >28˚C / 0.1 x specified accuracy per ˚C for temperatures <18˚C or >28˚C
    • Relative humidity: 95% up to 30˚C; 75% up to 40˚C; 45% up to 50˚C; 35% up to 55˚C
    • Vibration: Random 2g, 5Hz to 500Hz
    • Shock: 1m drop test
    • Size: 100mm x 203mm x 50mm
    • Weight: 610g
    • Safety: IEC 61010-1 1000V Cat III / 600V Cat IV
  • Product Questions

    Please Sign in or Create an account to post a question.

    There are no entries.

  • Reviews

    There are currently no reviews for this product. If you have previously purchased it please leave a review using our quick and easy form to the right.

    Write Your Own Review

    Only registered users can write reviews. Please, log in or register

  • Delivery Information

    At Test-Meter.co.uk we understand the importance of a reliable delivery service when shopping online. Especially when the goods are often essential to your working day. If your goods are required by a certain date please feel free to contact us for an honest and realistic indication whether this can be met. We aim to process all orders we receive within 1 to 3 working days, however from time to time we do have an increased demand for certain products or there might be delays from the manufacturer. In such cases delivery of your equipment may be subject to a minor delay.

    We use DPD/Interlink for all larger items and Royal Mail for smaller items and accessories. With DPD/Interlink you will receive a 1 hour delivery window on the day of delivery via e-mail/text and a notification 15 minutes before arrival so you will not have to wait around all day. You can even manage your booking online and re-arrange delivery for another date or arrange the goods to be left with a neighbour of your choice.

    We also offer delivery options for goods required urgently on certain products, all which are sent by DPD/Interlink.

    Our charges for UK deliveries:

    • FREE Delivery (on select products only): typically 3-5 working days*
    • Standard Delivery at £4.95: 2-3 working days
    • Next Working Day Delivery (on select products only) at £7.50
    • Pre-Noon Next Working Day Delivery (on select products only) at £9.50*
    • Pre-10.30am Next Working Day Delivery (on select products only) at £18.50*
    • Saturday Pre-Noon Delivery (on select products only) at £14.50*
    • Sunday Pre-Noon Delivery (on select products only) at £14.50*

    *UK mainland only

    NOTE! For next working day or Saturday/Sunday delivery options the order MUST be placed no later than 3pm on the working day before delivery is required. After 3pm, please arrange with our staff before selecting a priority delivery service. Priority services are available to UK mainland residents only (this might exclude certain areas in the north of Scotland).

    Customers outside the UK:

    Test-Meter.co.uk exports to many countries all over the world. Prices for shipping vary on location and weight/dimensions. Costs are calculated for certain countries at the checkout. If your country is not included in this list please e-mail admin@test-meter.co.uk with your name, address and the items you would like to order for an accurate shipping quote or go to http://www.test-meter.co.uk/test-equipment-export for more information.

    For more information on delivery, please see our terms and conditions.