Kane 251 Combustion Flue Gas Analyser Kit

SKU: KANE251KIT
  • Featuring the KANE251, an infrared printer, carry case & more
  • Perfect for the installation and service oil/gas boilers or biomass appliances
  • Also available with KANE251NO optional upgrade
More Info
Discontinued

Kane 251 Combustion Flue Gas Analyser Kit

This product has now been discontinued. Please find alternatives in our Flue Gas Analyser category.

Complete with an infrared printer and carry case, the Kane 251 Combustion Flue Gas Analyser Kit is the perfect kit for engineers installing or servicing oil boilers, gas engineers or anyone working with Biomass appliances.

Measuring CO2, CO and temperature and providing a range of calculated results, the KANE251 is a versatile instrument that boasts a higher range CO sensor (up to 10,000ppm) than it's sister model, the Kane 255, coming with a range of accessories including an infra-red linked printer, allowing test results to be quickly be printed on-site.

Ideal for engineers who install and service oil/gas boilers or biomass appliances, the Kane 251 Combustion Flue Gas Analyser Kit is an incredibly versatile and cost-effective bundle.

The Kane 251 is also available as the KANE251NO, with this optional upgrade offering the measurement of Nitric Oxide (NO) as well as all standard features.

What's In The Box?

  • Kane 251 Combustion Flue Gas Analyser
  • Charger
  • Batteries
  • KMCP2
  • Test report
  • Manual
  • KANE IRP-2
  • Case
Specification

Flue Temperature

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Inlet Temperature (Internal Sensor)

  • Range: 0-50°C
  • Resolution: 0.1°C
  • Accuracy: ±1°C, ±0.3% reading

Inlet Temperature (External Sensor)

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Oxygen (Using dry gases at STP)

  • Range: 0.21%
  • Resolution: 0.1%
  • Accuracy: ±0.3%

Carbon Monoxide (H2 compensated)

  • Range: 0-20ppm, 21-4,000ppm nom, 4,001ppm-10,000ppm max, 20,000pm max for 15 mins
  • Resolution: 1ppm
  • Accuracy: ±3ppm, ±5% of reading, ±10% of reading

Carbon Dioxide (Using dry gases at STP)

  • Range: 0-20%
  • Resolution: 0.1%
  • Accuracy: ±0.3% volume

Calculated Efficiency (Net or Gross)

  • Range: 0-99.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Efficiency High (C)

  • Range: 0-119.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Excess Air

  • Range: 0-250%
  • Resolution: 0.1%
  • Accuracy: ±0.2% reading

Calculated CO/CO2 ratio

  • Range: 0-0.999
  • Resolution: 0.0001
  • Accuracy: ±5% reading

Nitric Oxide Low Range (NO model only)

  • Range: 1ppm
  • Resolution: ±2ppm < 30ppm (using dry gases at STP), ±5ppm > 30ppm
  • Accuracy: 0 to 100ppm

Nitric Oxide High Range (NO model only)

  • Range: 1ppm
  • Resolution: ±5ppm < 100ppm (using dry gases at STP), ±5% reading > 100ppm
  • Accuracy: 0-1000ppm

General

  • Pre-programme fuels: Natural gas, Light Oil, Propane, Butane, LPG, Wood Pellets.
  • Weight: 1kg / 2.2lb
  • Handset Dimensions: 200mm / 7.9" x 45mm / 1.8" x 90mm / 3.5"
  • Probe Dimensions: L300mm / 11.8" x Dia 6mm / 0.25" with 200mm / 7.8" long stainless steel shaft, type K thermocouple and 3m / 6ft long neoprene hose
  • Ambient Operating Range: ±0°C to ±40°C / 32-104°F, 10% to 90% RH non-condensing
  • Storage Capacity: 20 sets of test results in volatile memory
  • Battery Life: 4AA cells > 8 hours using Alkaline AA cells
  • Charger (optional): 110Vac/220 Vac nominal for NMiH batteries only, 12V in vehicle charger for NMiH batteries only