Kane 450 Flue Gas Analyser CPA1 Kit

SKU: KANE450CPA1
  • Contains a Kane 450 Flue Gas Analyser, ideal for commercial and domestic boilers
  • ASP2 sampling kit allows testing on flueless gas appliances
  • Wide range of other probes and gas leak detector included
More Info
£946.80 £789.00
Discontinued

Kane 450 Flue Gas Analyser CPA1 Kit

This product has now been discontinued. The closest replacement options is the Kane 458s Flue Gas Analyser. Please feel free to call us to discuss suitable replacement products.

The Kane 450 Flue Gas Analyser CPA1 Kit is the most advanced kit available for the Kane 450. The analyser is capable of measuring or calculating a wide range of variables including CO, CO2, O2, pressure, temperature, efficiency and excess air. It can also perform a let by/tightness test and check flue draught and CO/CO2 ratio. It is ideal for use on both domestic and commercial boilers running from fuels such as natural gas, butane, propane, LPG, light oil and wood pellets.

The large internal memory of the Kane 450 has enough space for 99 combustion tests plus a range of other test results. Readings are shown on the four-line digital display and it is operated via a simple push button and dial interface. It has a hardwearing rubber holster with a built in magnet that allows it to be installed hands free on ferrous surfaces.

The Kane 450 CPA1 Kit stands out because of the wide array of probes supplied alongside the flue gas analyser. Firstly, a standard 300mm flue probe and pressure hose set are ideal for measurements on boilers whilst a pair type K temperature probes allow measurement of inflow and outflow temperatures in central heating systems.

A combustible gas leak detector helps the user locate leaking organic gases and a liquid/air temperature provides a great option for monitoring ambient conditions. Finally, a Kane ASP2 sampling probe kit is designed for analysing flueless appliances, for example gas fires and equipment in commercial kitchens.

Aside from a range of probes, the Kane 450 CPA1 also contains an in-vehicle charger in addition to the standard charger and a Kane infrared printer is included. This portable device allows the user to print reports on site via wireless communication with the analyser. The entire kit is supplied in a large carry case.

Kit Contents

  • Kane 450 Flue Gas Analyser
  • Kane Infrared Printer
  • Large carry case
  • GLD 450plus gas leak detector
  • KAL1 air/liquid temperature probe
  • 2 x pressure hoses
  • 2 x KPCP clamp-on temperature probes
  • Flue probe
  • 2 x Pressure connectors
  • ASP2 sampling probe kit
  • Wall charger
  • In-vehicle charger
  • Calibration report
  Standalone Standard Kit PRO Kit CPA1 Kit
Kane 450 Flue Gas Analyser
300mm flue probe
Pressure connectors 2 2 2 2
KAL1 air/liquid probe    
KPCP pipe clamp probes     2 2
ASP2 sampling probe kit      
Kane IRP-2 IR Printer  
Carry case  
Wall charger
In-vehicle charger      
Calibration report

What's In The Box?

  • Kane 450 Flue Gas Analyser
  • Kane Infrared Printer
  • Large carry case
  • GLD 450plus gas leak detector
  • KAL1 air/liquid temperature probe
  • 2 x pressure hoses
  • 2 x KPCP clamp-on temperature probes
  • Flue probe
  • 2 x Pressure connectors
  • ASP2 sampling probe kit
  • Wall charger
  • In-vehicle charger
  • Calibration report
Specification

Temperature Measurements

  • Flue range: 0 to 600˚C
  • Flue resolution: 0.1˚C
  • Flue accuracy: ±2˚C or ±0.3%
  • Inlet temperature (internal sensor) range: 0 to 50˚C
  • Inlet temperature (internal sensor) accuracy: ±1˚C or ±0.3%
  • Inlet temperature (internal sensor) resolution: 0.1˚C
  • Inlet temperature (external sensor) range: 0 to 600˚C
  • Inlet temperature (external sensor) accuracy: ±2˚C or ±0.3%
  • Inlet temperature (external sensor) resolution: 0.1˚C

Pressure Measurements

  • Range: ±20Pa / ±100Pa / ±2000Pa / ±80hPa 
  • Resolution: 0.1Pa / 0.1Pa / 1Pa / 0.01hPa
  • Accuracy: ±0.5Pa / ±3Pa / ±3% / ±3%

Gas Measurements

  • Oxygen range: 0 to 21%
  • Oxygen accuracy: ±0.2%
  • Oxygen resolution: 0.1%
  • Carbon monoxide range: 0 to 2000ppm nom (4000ppm max for 15 minutes)
  • Carbon monoxide accuracy: ±10ppm (<100ppm) / ±5%
  • Carbon monoxide resolution: 1ppm
  • Carbon monoxide (H2-compensated) range: 0 to 4000ppm 
  • Carbon monoxide (H2-compensated) accuracy: ±10ppm (< 100ppm) / ±5%
  • Carbon monoxide (H2-compensated) resolution: 1ppm
  • Carbon dioxide range: 0 to 30%
  • Carbon dioxide accuracy: ±0.3%
  • Carbon dioxide resolution: 0.1%

Other Measurements

  • Efficiency range: 0 to 99.9%
  • Efficiency accuracy: ±1%
  • Efficiency resolution: 0.1%
  • Excess air range: 0 to 250%
  • Excess air accuracy: ±0.2%
  • Excess air resolution: 0.1%

General

  • Pre-programmed fuels: Natural gas, light oil, propane, butane, LPG, wood pellets
  • Handset dimensions: 200mm x 45mm x 90mm
  • Probe dimensions: 300mm x 6mm x 200mm
  • Weight: 0.77kg
  • Operating temperature: 0 to 40˚C (10 to 90% RH)
  • Internal memory: 99 combustion tests, 20 pressure tests, 20 tightness tests, 20 temperature tests, 20 ambient CO tests
  • Batteries: 4 x AA
  • Battery life: >12 hours