Kane 945 Industrial Flue Gas Analyser

SKU: KANE945
  • An industrial flue gas analyser with an incorporated heavy duty pump
  • Measures a wide range of variables, upgradeable with additional sensors
  • Suitable for industrial/commercial appliances using various fuels
More Info
Discontinued

Kane 945 Industrial Flue Gas Analyser

This product has now been discontinued. The closet replacement product is the Kane 975 Industrial Flue Gas Analyser. For alternative products please feel free to call the office to discuss your requirements.

The Kane 945 Industrial Flue Gas Analyser is a powerful instrument that is intended for use in industrial and commercial appliances that burn fuels including oil, gas and biomass. In addition to a range of useful measurement functions, the analyser also has an integrated heavy duty pump to assist analysis on commercial boilers.

The Kane 945 is capable of measuring oxygen (0 to 25%), carbon monoxide (0 to 4000ppm, H2-compensated sensor), temperature and pressure as standard. This allows it to calculate further values including CO2, CO/CO2 ratio, combustion efficiency and excess air. The analyser is therefore suitable for performance checks, safety checks, flue draught measurements and other tests during the installation, commissioning and servicing of industrial appliances.

Alongside the standard measurement and calculation functions, a set of optional sensors can be fitted to the Kane 945 thanks to the upgradeable design. It is possible to add a high range CO sensor (0 to 10%), an SO2 sensor (0 to 5000ppm), an NO sensor (0 to 5000ppm), a low range NO sensor (0 to 100ppm), and an NO2 sensor (0 to 1000ppm). Please note that sensors can only be fitted by Kane upon purchase or during servicing and that a maximum of TWO sensors can be fitted to a single analyser.

The Kane 945 has a clear digital display capable of showing up to eight readings at once and it can store up to 150 test results in its internal memory. These can then be printed using an optional infrared printer or the user can choose to add an optional Android wireless module which allows data transfer to Kane Live software or the free Kane Live app. Reports can then be generated and printed from an appropriate smart device.

A flue probe, carry case and calibration report are supplied as standard with the Kane 945 and it has a compact, portable design despite being suitable for heavy duty industrial applications. It has a practical eight-hour battery life

Key Features

  • Measures: Oxygen, carbon monoxide, temperature and pressure
  • Calculates: CO2, CO/CO2 ratio, combustion efficiency and excess air
  • Optional sensors: High range CO, SO2, NO, low range NO, NO2
  • Heavy-duty industrial pump
  • Ideal for commercial and industrial appliances
  • Fuels include natural gas, town gas, Gascor, light oil, heavy oil, propane, butane, anthracite, coke, coal, Kinsale gas
  • Internal memory for up to 150 test results
  • Flue probe, carry case and calibration report provided

What's In The Box?

  • Kane 945 Flue Gas Analyser
  • Flue probe
  • Battery charger
  • Kane 945 instruction manual
  • Calibration report
  • Carry case
Specification

Temperature Measurement

  • Flue temperature range: 0 to 1200˚C
  • Flue temperature accuracy: ±2˚C ± 0.3%
  • Flue temperature resolution: 0.1˚C/˚F
  • Inlet temperature range: 0 to 50˚C
  • Inlet temperature accuracy: ±1˚C ± 0.3%
  • Inlet temperature resolution: 0.1˚C/˚F

Gas Measurements

  • Oxygen range: 0 to 25%
  • Oxygen accuracy: ±0.2%
  • Oxygen resolution: 0.1%
  • Carbon monoxide (H2 compensated) range: 0 to 4000ppm
  • Carbon monoxide (H2 compensated) accuracy: ±5ppm <100ppm; ±20ppm <400ppm; ±5% <400ppm
  • Carbon monoxide (H2 compensated) resolution: 1ppm

Pressure Measurement

  • Pressure range: 150mbar
  • Pressure accuracy: ±0.5%
  • Pressure resolution: 0.1mbar

Calculated Values

  • Carbon dioxide range: 0 to 99.9%
  • Carbon dioxide accuracy: ±0.3%
  • Carbon dioxide resolution: 0.1%
  • Losses range: 0 to 99.9%
  • Losses accuracy: ±1%
  • Losses resolution: 0.1%
  • Efficiency range: 0 to 99.9%
  • Efficiency accuracy: ±1%
  • Efficiency resolution: 0.1%
  • Excess air range: 0 to 2885%
  • Excess air accuracy: ±0.2%
  • Excess air resolution: 0.1%
  • (Nett) temperature range: 0 to 1200˚C
  • (Nett) temperature accuracy: ±2˚C ± 0.3%
  • (Nett) temperature resolution: 1˚C
  • CO/CO2 ratio range: 0 to 0.9999
  • CO/CO2 ratio accuracy: ±0.0001
  • CO/CO2 ratio resolution: 0.0001
  • Poison index range: 0 to 99.99 range
  • Poison index accuracy: ±0.01
  • Poison index resolution: 0.01

Optional Gas Measurements

  • Carbon monoxide (high range) range: 0 to 100,000ppm
  • Carbon monoxide (high range): ±5ppm <100ppm; ±20ppm <400ppm; ±5% <400ppm
  • Carbon monoxide (high range) resolution: 1ppm
  • Nitric oxide (low) range: 0 to 100ppm
  • Nitric oxide (low) accuracy: ±3ppm <200ppm; ±5ppm <100ppm
  • Nitric oxide (low) resolution: 1ppm
  • Nitric oxide range: 0 to 5000ppm
  • Nitric oxide accuracy: ±5ppm <100ppm; ±5% >100ppm
  • Nitric oxide resolution: 1ppm
  • Nitrogen dioxide range: 0 to 100ppm
  • Nitrogen dioxide accuracy: ±3ppm <200ppm; ±5ppm <100ppm
  • Nitrogen dioxide resolution: 1ppm
  • Sulphur dioxide range: 0 to 5000ppm
  • Sulphur dioxide accuracy: ±5ppm <100ppm; ±5% >100ppm
  • Sulphur dioxide resolution: 1ppm

General

  • Pre-programmed fuels: Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas
  • Dimensions (handset): 220mm x 55mm x 120mm
  • Dimensions (probe): 240mm x ø8mm x 285mm, 1.5m neoprene hose
  • Operating temperature: -5˚C to +50˚C/10% to 90% RH non condensing
  • Power supply: Input, 110Vac/220 Vac nominal; Output, 12 Vac off load
  • Battery life: >8 hours