Keller LEO1 Ei Intrinsically Safe Digital Manometer (3bar)

SKU: KELL303005.0006
  • Pressure measurement from -1bar to 3bar with 1mbar precision readings
  • Certified as intrinsically safe for use in hazardous environments
  • PEAK mode captures peak and trough pressure readings
More Info
In Stock - Available Next Day

Keller LEO1 Ei Intrinsically Safe Digital Manometer (3bar)

The Keller LEO1 Ei Intrinsically Safe Digital Manometer is suitable for measuring pressure in hazardous ATEX environments. It has a pressure range of -1 to 3bar and an accuracy of ±0.1% FS alongside a resolution of 1mbar. It has a G1/4” male connector that minimises fluid loss.

The pressure meter is suitable for use in hazardous environments where there is a risk of explosion as it is certified as intrinsically safe. It is classified as Ex II 1 G and EEx ia IIC T6 or T5, with a certification file of LCIE 01 ATEX 6001 X.

The Keller LEO1 Ei has two measurement modes. The MANO mode takes two readings per second and produces the current reading alongside the minimum or maximum reading on screen. The PEAK mode takes 5000 readings per second and shows either the peak or trough reading on screen with the current pressure.

Relative measurements are facilitated by the Keller LEO1 Ei’s zero function that negates the effects of variable barometric pressure. The clear digital screen shows pressure in bar, mbar, hPa, kPa, MPa, PSI, kp/cm2 whilst operation is conducted using just two buttons.

The Keller LEO1 Ei has an IP65 ingress protection rating and a 1000-hour battery life as well as a compact, lightweight design.

Keller part number: 303005.0006

Key Features

  • Intrinsically safe pressure meter
  • Ex II 1 G; EEx ia IIC T6 or T5
  • PEAK or MANO measurement mode
  • Range: -1bar to 3bar
  • Accuracy: ±0.1% FS
  • Resolution: 1mbar
  • IP65 ingress protection rating
  • Zero function for relative measurement
  • 1000-hour battery life
  ECO2 LEO1 LEO2 LEO3 LEO5 LEO Record LEX1
-1 to 3bar  
-1 to 31bar
0 to 100bar            
0 to 300bar
0 to 400bar            
0 to 700bar    
0 to 1000bar      
Accuracy ±0.5% FS ±0.1% FS ±0.1% FS ±0.1% FS ±0.05% FS ±0.1% ±0.05% FS
Resolution
(at smallest range)
10mbar 1mbar 1mbar 1mbar 1mbar 1mbar 0.1mbar
Temperature range         0˚C to 50˚C    
Temperature accuracy         ±1˚C    
Intrinsically safe
version
   
Peak mode          
Pressure connector 7/16" UNF G 1/4" 7/16" UNF G 1/4" G 1/4" G 1/4" G 1/4"
Analogue output          
Internal memory        
Data port       RS485 Binder USB RS485 Fischer RS485 Fischer
Compatible with
Keller-Bus protocol
       
Specification
  • Classification: Ex II G, EEx ia IIC T6 or T5
  • Certification file: LCIE 01 ATEX 6001 X
  • Range: -1 to 3bar
  • Resolution: 1mbar
  • Overpressure: 10bar
  • Accuracy (at room temperature): <0.1% FS
  • Total error band (0…50˚C): <0.2% FS
  • Storage temperature: -20 to 70˚C
  • Operating temperature: 0 to 50˚C
  • Compensated temperature range: 0 to 50˚C
  • Supply: 3V battery, CR2430
  • Battery life: 1000 hours in MANO mode, 150 hours in PEAK mode
  • Pressure connection: G1/4”
  • Ingress protection rating: IP65
  • Dimensions: 76mm x 118mm x 42mm
  • Weight: 210g
Label Type Size Download
pdf Keller LEO1 Datasheet pdf 472.2 KB Download