Kewtech EZYPAT Plus PAT Test Kit C

SKU: KEWTEZYPATPLUSKITC
  • A useful set of accessories for the Kewtech EZYPAT Plus PAT Tester
  • Includes testing instruments for both microwave leakage and 230V sockets
  • Set of 110V adaptors and IEC adaptors for IT and construction equipment
More Info
£610.80 £509.00
In Stock - Available Next Day

Kewtech EZYPAT Plus PAT Test Kit C

Kewtech EZYPAT Plus PAT Test Kit C features the Kewtech EZYPAT Plus PAT Tester. This instrument performs 230V load and run testing in addition to standard PAT testing, with automatic test sequences for Class I, Class II and IEC/extension leads. Standard tests include earth bond testing, insulation testing, substitute leakage measurement and polarity checking. Test sequences are initiated using specific test buttons and results are shown on the large digital screen.  The EZYPAT Plus shows users a clear indication of PASS/FAIL tests. The LCD screen flashes green to indicate a pass, red indicates a fail and a blue screen shows that a test is being performed. 

The various PAT testing accessories in Kewtech EZYPAT Plus Kit C help expand the scope and recording capabilities of the tester. The 110V PAT adaptors allow testing - including powered testing - on appliances and extension leads found on construction sites whilst an IEC adaptor set allows testing on leads used with IT equipment. Additional items include a PAT certificate pad, PAT register books, a range of PAT labels, a microwave leakage detector, a socket tester, and a carry case.

The EZYPAT Plus is manually compatible with the KEWPAT app, providing users with storage for testing and generating reports. Users are also able to register their devices on the free APP.

Kit Contents

  • Kewtech EZYPAT Plus PAT Tester
  • Two rolls of Pass labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector (x150)
  • Microwave labels (x50)
  • Tuff Tag Pass labels
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case

  Kit A Kit B Kit C
Kewtech EZYPAT Plus PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT register book x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
110V power adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector  
Microwave emission labels  
Kewtech KITBAG2 carry case  

What's In The Box?

  • Kewtech EZYPAT Plus PAT Tester
  • 2 x Pass labels
  • Fail labels
  • PassWrap labels
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector
  • Microwave labels (x50)
  • Tuff Tag Pass labels
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case
Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Mains Voltage

  • Display range: 30 - 270 V
  • Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V
  • Resolution & Accuracy: 1 V & ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V; 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Insulation Test between L and N

  • Open-circuit voltage: 4.5 V ±0.5 V DC
  • Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Run Leakage (Item: Load current / Leakage current)

  • Mains voltage range: 100 - 253 V / 50 Hz
  • Measuring range: 0.10 - 13.00 A rms / 0.10 - 20.00 mA rms
  • Display range: 0.00 - 13.00 A / 0.00 - 20.00 mA
  • Over-range indication: > 13.00 A / > 20.00 mA
  • Resolution: 0.01A / 0.01mA
  • Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
  • Max. rating: 3 kVA max., 15 sec. cont. / -
Label Type Size Download