Megger PAT420 Industrial PAT Testing Kit

SKU: MEGGPAT420IKIT
  • Includes the Megger PAT420, featuring a large memory and inbuilt 110V socket
  • Adaptors for 110V equipment, 230V equipment and 415V three-phase appliances
  • Megger PAT Label Printer and barcode scanner streamline testing process
More Info
£1,858.80 £1,549.00
Due to ship mid-June

Megger PAT420 Industrial PAT Testing Kit

The Megger PAT420 Industrial PAT Testing Kit is a handy option for those with PAT testing needs in industrial environments such as factories, repair shops and production plants.

The Megger PAT420 PAT Tester is a downloadable instrument with a large memory and a wide range of testing functions for making sure appliances and extension leads are safe to use. These tests include earth bond (200mA, 10A, 25A), insulation (250V/500V), operational VA (load & run), portable RCD testing, differential/substitute/touch earth leakage, and extension lead and power cord testing. An integrated 110V adaptor allows testing of power tools and other construction-related appliances.

The internal memory of the Megger PAT420 has room for up to 10,000 records and this can be exported as Excel documents using the supplied USB cable. Pre-set automatic test sequences are available for Class I appliances, Class II appliances and IEC/extension leads whilst individual trigger buttons enable individual tests to be carried out. The QWERTY keyboard allows the user to enter additional notes with records and the sturdy construction is ideal for challenging industrial environments.

Several different adaptors are provided in the Megger PAT420 Industrial PAT Kit. These include appliance and extension lead adaptors for use with items operating at 230V/16A and 230V/32A and appliances operating at 110V/32A whilst an extension lead adaptor is provided for 110V/16A leads. The integrated 110V socket on the Megger PAT420 is capable of powering 16A appliances. Finally, a set of 415V adaptors allow testing on three-phase equipment found in factories, workshops and other commercial facilities.

In addition to adaptors and the tester, the Megger PAT420 Industrial PAT Kit also includes a Megger PAT400 PAT Label Printer which allows the user to print customised PAT labels with barcodes and appliance information alongside test results. Additionally, the supplied Megger Barcode Scanner allows the user to instantly recall appliance data to the tester’s screen in order to better organise the onboard database.

Kit Contents

  • Megger PAT420 PAT Tester
  • Megger PAT400 PAT Label Printer
  • Megger PAT400 Barcode Scanner
  • 110V/16A extension lead adaptor
  • 110V/32A appliance adaptor
  • 110V/32A extension lead adaptor
  • 230V/16A appliance adaptor
  • 230V/16A extension lead adaptor
  • 230V/32A appliance adaptor
  • 230V/32A extension lead adaptor
  • 415V/16A 4-pin appliance adaptor
  • 415V/32A 4-pin appliance adaptor
  • 415V/16A 4-pin extension lead adaptor
  • 415V/32A 4-pin extension lead adaptor
  • 415V/16A 5-pin appliance adaptor
  • 415V/32A 5-pin appliance adaptor
  • 415V/16A 5-pin extension lead adaptor
  • 415V/32A 5-pin extension lead adaptor
  • Earth Bond Test Lead
  • 230V Extension Lead Adaptor
  • Calibration Certificate
  • PAT420 Carry Case

Megger PAT420 PAT Testing Kit Comparisons

  Kit 1 Kit 2 Kit 3 Industrial Kit
Megger PAT420 Tester
SimplyPATs V7 Software    
PAT400 Barcode Label Printer  
2x Printer Cartridges    
PAT400 Barcode Scanner  
Microwave Leakage Detector    
50 Microwave Emission Labels    
Pass Labels 500 1000 1000  
Fail Labels 200 400 400  
PassWrap Labels   250 250  
110V Extension Lead Adaptor  
IEC Adaptor Kit less IEC Clover  
110V Adaptor Set      
230V Adaptor Set      
415V 4-Pin Adaptor Set      
415V 5-Pin Adaptor Set      
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT420 Carry Case

What's In The Box?

  • Megger PAT420 PAT Tester
  • Megger PAT400 PAT Label Printer
  • Megger PAT400 Barcode Scanner
  • 110V/16A extension lead adaptor
  • 110V/32A appliance adaptor
  • 110V/32A extension lead adaptor
  • 230V/16A appliance adaptor
  • 230V/16A extension lead adaptor
  • 230V/32A appliance adaptor
  • 230V/32A extension lead adaptor
  • 415V/16A 4-pin appliance adaptor
  • 415V/32A 4-pin appliance adaptor
  • 415V/16A 4-pin extension lead adaptor
  • 415V/32A 4-pin extension lead adaptor
  • 415V/16A 5-pin appliance adaptor
  • 415V/32A 5-pin appliance adaptor
  • 415V/16A 5-pin extension lead adaptor
  • 415V/32A 5-pin extension lead adaptor
  • Earth Bond Test Lead
  • 230V Extension Lead Adaptor
  • Calibration Certificate
  • PAT420 Carry Case
Specification

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 VA - 999 VA), ±5% ±100 digits (1000 VA - 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 4.4kg