  • Carries out comprehensive electrical safety testing on industrial machinery
  • Multi-system testing for use on TT, TN, IT and 115V supply systems
  • High-resolution touchscreen with pre-set AUTOSEQUENCEs

rrp £6,714.62

now £5,590.00 (Ex. VAT) £6,708.00 (Inc. VAT)

rrp £6,714.62

OR

Please select a free gift below.

  • Description

    Metrel MI3325 MultiServicer XD Machinery / Electrical Safety Tester

    Metrel MI3325

    The Metrel MI3325 MultiServicer XD Machinery / Electrical Safety Tester is a multifunction instrument that is useful for performing a wide range of different tests on industrial machinery. These include standard electrical safety tests such as earth bond continuity, HV AC testing, insulation tests and leakage current (sub leakage, differential, PE, touch).

    It is also capable of more sophisticated functional tests and RCD testing in addition to polarity and current measurement with clamps. The Metrel MI3325 can measure voltage, frequency and phase rotation, perform a varistor test, measure voltage drop and measure discharge time. Notably, there is a loop and line impedance testing function with prospective fault current measurement.

    The Metrel MI3325 is operated via a 4.3” colour touch screen and a set of simple navigation buttons. Metrel’s AUTOSEQUENCEs enable quick, comprehensive testing of pre-saved instruments. Built-in help screens assist the operator during use and the tester also has an integrated fuse table that allows automatic evaluation of the line/loop impedance result. All three voltages in three-phase systems are monitored in real time and the unit is suitable for TT, TN, IT and 115V supply systems.

    Various communication channels are available on the Metrel MI3325 including wireless Bluetooth connectivity, an RS-232 port, a USB port and an Ethernet port. This allows pre-set test sequences or data to be uploaded to the tester from a PC and test results to be downloaded back to the PC from the 8GB SD card memory (expandable up to 32GB).

    The Metrel MI3325 can test the safety of machinery in accordance with IEC/EN 60204 Ed.5 and IEC 60204 Ed.6; the safety of low-voltage switchgear and controlgear in accordance with IEC/EN 61439-1 Ed.2; the safety of portable appliances in accordance with VDE 0701-0702 and AS / NZS 3760 Code of Practice; and the safety of arc welding equipment in compliance to IEC/EN 60974-4 Ed.2 (Metrel A1422 adaptor required).

    Metrel part number: MI 3325

    Key Features

    • Continuity testing: 0.2A, 4A, 10A, 25 + Voltage @ 10A (2W & 4W)
    • HV AC, programmable 100V to 5000V
    • Insulation resistance: 250V, 500V, and 1000V test voltages
    • Leakage current: sub-leakage, differential, PE, touch
    • Functional test: power P/S/Q, voltage, current, cos fi, frequency, ThdU, ThdI, PF
    • RCD test: Types A, AC, B, B+ and F
    • Tests welding equipment with Metrel A1422 (optional)
    • Polarity check
    • Clamp current
    • Voltage, frequency, phase rotation
    • Varistor test
    • Z loop and line testing with PFC and/or PSC
    • Voltage drop
    • Discharging time
  • Specification

    Continuity 2W, 4W, test current (0.2 A, 4 A, 10 A, 25 A)

    • Function: - R
    • Measuring ranges: 0.00 Ω ... 19.99 Ω; 20.0 Ω ... 99.9 Ω; 100.0 Ω ... 199.9 Ω; 200 Ω ... 999 Ω
    • Resolution: 0.01 Ω; 0.1 Ω; 0.1 Ω; 1 Ω
    • Accuracy: ±(2 % of reading + 2 D); ±(3 % of reading); ±(5 % of reading); Indicative

    Voltage drop (Iout = 10 A)

    • Function: - ∆U
    • Measuring range: 0.00 Ω ... 19.99 Ω; 20.0 Ω ... 99.9 Ω
    • Resolution: 0.01Ω; 0.1Ω
    • Accuracy: ±(2 % of reading + 5 D); ±(3 % of reading)

    HVAC, programmable HV AC, output voltage, * 100 V - 2500 V, ** 2510 V - 5000 V (floating to earth)

    Voltage (AC)

    • Ranges: 0V to 1999V; 2.00kV to 5.99kV
    • Resolution: 1V; 10V
    • Accuracy: ±(3% of reading)

    Current, apparent

    • Range: 0.0mA to 49.9mA / 99.9mA
    • Resolution: 0.1mA
    • Accuracy: ±(3% of reading + 3 D)

    Current, resistive

    • Range: 0.0mA to 49.9mA / 99.9mA
    • Resolution: 0.1mA
    • Accuracy: Indicative

    Current capacitive

    • Ranges: -49.9 mA ... 49.9 mA**; -99.9 mA ... 99.9 mA*
    • Resolution: 0.1mA
    • Accuracy: Indicative
    • Short circuit current: >200mA
    • Output power: 250VA max

    Insulation resistance (250 V, 500 V), insulation resistance - S (250 V, 500 V), Riso - PAT / Riso - welding

    Riso/Riso-s

    • Ranges: 0.08 MΩ ... 19.99 MΩ; 20.0 MΩ ... 99.9 MΩ; 100.0 MΩ ... 199.9 MΩ
    • Resolution: 0.01MΩ; 0.1MΩ; 0.1MΩ
    • Accuracy: ±(3 % of reading + 2 D); ±(5 % of reading); ±(10 % of reading)

    Output voltage

    • Range: 0V to 600V
    • Resolution: 1V
    • Accuracy: ±(3% of reading + 2D)

    Insulation resistance (500 V and 1000 V) ISO installation

    Riso

    • Ranges: 0.15 MΩ ... 19.99 MΩ; 20.0 MΩ ... 199.9 MΩ; 200.0 MΩ ... 999 MΩ
    • Resolution: 0.01MΩ; 0.1MΩ; 1MΩ
    • Accuracy: ±(5 % of reading + 3 D); ±(5 % of reading); ±(10 % of reading)

    Output voltage

    • Range: 0V to 1200V
    • Resolution: 1V
    • Accuracy: ±(3% of reading + 3D)

    Insulation resistance (50 V, 100 V and 250 V) ISO Installation

    Riso

    • Ranges: 0.15 MΩ ... 19.99 MΩ; 20.0 MΩ ... 99.9 MΩ; 100.0 MΩ ... 199.9 MΩ
    • Resolution: 0.01MΩ; 0.1MΩ; 0.1MΩ
    • Accuracy: ±(5 % of reading + 2 D); ±(10 % of reading); ±(20 % of reading)

    Output voltage

    • Range: 0V to 300V
    • Resolution: 1V
    • Accuracy: ±(3% of reading + 3D)

    Measuring range according to EN 61557 0.15 MOhm ... 999 MOhm

    Substitute leakage (Isub, Isub-S), open circuit voltage, 110 V AC, 230 V AC

    Isub

    • Range: 0.02mA to 1.99mA
    • Resolution: 0.01mA
    • Accuracy: ±(3% of reading + 3 digit)

    Isub s

    • Range: 2.00mA to 19.99mA
    • Resolution: 0.01mA
    • Accuracy: ±(5% of reading)

    Differential leakage current

    • Function: Idiff
    • Ranges: 0.010 mA ... 1.999 mA; 2.00 mA … 19.99 mA
    • Resolution: 0.001mA; 0.01mA
    • Accuracy: ±(3 % of reading + 10 D); ±(5 % of reading)

    PE leakage current

    • Function: Ipe
    • Ranges: 0.010 mA ... 1.999 mA; 2.00 mA … 19.99 mA
    • Resolution: 0.001mA; 0.01mA
    • Accuracy: ±(3 % of reading + 3 D); ±(5 % of reading)

    Touch leakage current

    • Function: Itou
    • Ranges: 0.010 mA ... 1.999 mA; 2.00 mA … 19.99 mA
    • Resolution: 0.001mA; 0.01mA
    • Accuracy: ±(3 % of reading + 3 D); ±(5 % of reading)
    • Operating range (acc. to EN 61557-16): 0.010 mA ..... 19.99 mA

    Power

    P (active)

    • Ranges: 0.00 W … 19.99 W; 20.0 W … 199.9 W; 200 W ... 1999 W; 2.00 kW ... 3.70 kW
    • Resolution: 0.01W; 0.1W; 1W; 10W
    • Accuracy: ±(5 % of reading + 5 D); ±(5 % of reading); ±(5 % of reading); ±(5 % of reading)

    S (apparent)

    • Ranges: 0.00 VA … 19.99 VA; 20.0 VA … 199.9 VA; 200 VA ... 1999 VA; 2.00 kVA ... 3.70 kVA
    • Resolution: 0.01 VA; 0.1 VA; 1 VA; 10 VA
    • Accuracy: ±(5 % of reading + 10 D); ±(5 % of reading); ±(5 % of reading); ±(5 % of reading)

    Q (reactive)

    • Ranges: 0.00 VAr … 19.99 VAr; 20.0 VAr … 199.9 VAr; 200 VAr ... 1999 VAr; 2.00 kVAr ... 3.70 kVAr
    • Resolutions: 0.01 VAr; 0.1 VAr; 1 VAr; 10 VAr
    • Accuracy: ±(5 % of reading + 10 D); ±(5 % of reading); ±(5 % of reading); ±(5 % of reading)

    PF

    • Ranges: 0.00 i ... 1.00 i; 0.00 c ... 1.00 c
    • Resolution: 0.01; 0.01
    • Accuracy: ±(5 % of reading + 5 D); ±(5 % of reading + 5 D)

    THDU

    • Range: 0.0 % ... 99.9 %
    • Resolution: 0.1%
    • Accuracy: ±(5 % of reading + 5 D)

    THDI

    • Range: 0 mA … 999 mA; 1.00 A ... 16.00 A
    • Resolution: 1mA; 0.01A
    • Accuracy: ±(5 % of reading + 5 D); ±(5 % of reading)

    Cos Phi

    • Ranges: 0.00 i ... 1.00 i; 0.00 c ... 1.00 c
    • Resolution: 0.01; 0.01
    • Accuracy: ±(5 % of reading + 5 D)

    U

    • Ranges: 0.1 V ... 199.9 V; 200 V ... 264 V
    • Resolution: 0.1; 1 V
    • Accuracy: ±(3 % of reading + 10 D); ±(3 % of reading)

    I

    • Ranges: 0 mA … 999 mA; 1.00 A ... 16.00 A
    • Resolution: 1 mA; 0.01 A
    • Accuracy: ±(3 % of reading + 5 D); ±(3 % of reading)

    RCD testing / current shape AC, A, F, B, B+ / RCD type (non-delayed, S time-delayed, PRCD, PRCD-K, PRCD-S)

    - I∆ – Trip-out current

    • Ranges: 0.2 xI∆N ... 1.1 xI∆N (AC type); 0.2 xI∆N ... 1.5 xI∆N (A type, I∆N≥30 mA); 0.2 xI∆N ... 2.2 xI∆N (A type, I∆N<30 mA); 0.2 xI∆N ... 2.2 xI∆N (B type)
    • Resolution: 0.05 xI∆N
    • Accuracy: ±0.1 xI∆N

    Uc - Contact voltage

    • Ranges: 0.0 V ... 19.9 V; 20.0 V ... 99.9 V
    • Resolution: 0.1V
    • Accuracy: (-0 % / +15 %) of reading ± 10 D; (-0 % / +15 %) of reading 

    UC I∆N - Contact voltage

    UcI∆

    • Ranges: 0.0 V ... 19.9 V; 20.0 V ... 99.9 V
    • Resolution: 0.1 V
    • Accuracy: (-0 % / +15 %) of reading ± 10 D; (-0 % / +15 %) of reading

    t∆N trip out time

    • Ranges: 0.0 ms ... 40.0 ms; 0.0 ms ... max. time*
    • Resolution: 0.1ms
    • Accuracy: ±1ms; ±3ms

    *For max time refer to manual.

    Trip out time

    • Function: tI∆
    • Range: 0ms to 300ms
    • Resolution: 0.1ms
    • Accuracy: ±3ms 

    Polarity, test voltage (normal) < 50 V / test voltage (active) mains voltage

    • Power consumption of tested device during the active test…….< 25 VA 

    Clamp current (true RMS current using 1000:1 current clamp)

    I

    • Range: 0.00mA to 9.99mA
    • Resolution: 0.01mA
    • Accuracy: ±(5% of reading + 10D)

    Idiff

    • Range: 10.0mA to 99.9mA
    • Resolution: 0.1mA
    • Accuracy: ±(5% of reading + 5D)

    Ipe

    • Ranges: 100 mA ... 999 mA; 1.00 A ... 9.99 A; 10.0 A ... 24.9 A
    • Resolution: 1mA; 0.01A; 0.1A
    • Accuracy: ±(5% of reading + 5D)
    • Accuracy of current transformer is not considered.
    • Frequency range of current clamp is not considered.

    Voltage (online terminal voltage monitor (10 … 550 V) + phase rotation)

    TRMS (14 … 500 Hz) Uln, Ulpe, Unpe, U1pe, U2pe, U12, U13, U23

    • Range: 0V to 550V
    • Resolution: 1V
    • Accuracy: ±(2% of reading + 2D)

    Frequency

    • Range: 0.00 Hz ... 9.99 Hz; 10.0 Hz ... 499.9 Hz
    • Resolution: 0.01Hz; 0.1Hz
    • Accuracy: ±(0.2% of reading + 1D)

    Varistor test

    DC voltage

    • Range: 0V to 1000V
    • Resolution: 1V
    • Accuracy: ±(3% of reading + 3D)

    AC voltage

    • Range: 0V to 625V
    • Resolution: 1V
    • Accuracy: Consider accuracy of DC voltage.

    R low - resistance of earth connection and equipotential bonding

    R

    • Ranges: 0.16 Ω ... 19.99 Ω; 20.0 Ω ... 199.9 Ω; 200 Ω ... 1999 Ω
    • Resolution: 0.01Ω; 0.1Ω; 1Ω
    • Accuracy: ±(3 % of reading + 3 D); ±(5 % of reading); ±(5 % of reading)
    • Measuring range according to EN 61557: 0.16Ω to 1999Ω

    - R+, R-

    • Ranges: 0.0 Ω ... 199.9 Ω; 200 Ω ... 1999 Ω
    • Resolution: 0.1Ω; 1Ω
    • Accuracy: ±(5 % of reading + 5 D); ±(5 % of reading + 5 D)
    • Open circuit voltage: 6.5V DC to 18V DC
    • Measuring current: Min. 200mA into load resistance of 2Ω
    • Test lead compensation: Up to 5Ω

    Impedance Z loop, (L-PE, Test current @ 230 V … 20 A (10 ms))

    • Function: Z – Fault loop impedance
    • Measuring range: 0.00 Ω ... 9.99 Ω; 10.0 Ω ... 99.9 Ω; 100 Ω ... 999 Ω; 1.00 kΩ ... 9.99 kΩ
    • Resolution: 0.01 Ω; 0.1 Ω; 1 Ω; 10 Ω
    • Accuracy: ±(5 % of reading + 5 D); ±(10 % of reading); ±(10 % of reading); ±(10 % of reading)
    • Measuring range according to EN 61557 0.12 Ω ... 9.99 kΩ

    Impedance Zs rcd, L-PE

    Z - Zs Rcd

    • Ranges: 0.00 Ω ... 9.99 Ω; 10.0 Ω ... 99.9 Ω; 100 Ω ... 999 Ω; 1.00 kΩ .... 9.99 kΩ
    • Resolution: 0.01 Ω; 0.1 Ω; 1 Ω; 10 Ω
    • Accuracy: ±(5 % of reading + 12 D); ±(5 % of reading + 12 D); ±(10 % of reading); ±(10 % of reading)
    • Measuring range according to EN 61557 is 0.46 Ohm ... 9.99 kOhm for Itest = normal and 0.48 Ohm ... 9.99 kOhm for Itest = low.

    Ipsc - prospective fault current

    • Measuring range: 0.00 A ... 9.99 A; 10.0 A … 99.9 A; 100 A … 999 A; 1.00 kA … 9.99 kA; 10.0 kA … 23.0 kA
    • Resolution: 0.01A; 0.1A; 1A; 10A; 100A
    • Accuracy: Consider accuracy of fault loop resistance measurement

    Ulpe - voltage

    • Range: 0 V … 550 V; 20.0 V ... 99.9 V* * for Z - Zs Rcd function
    • Resolution: 1V; 0.1V
    • Accuracy: ±(2% of reading + 2 D)

    Impedance Z line (L-L, L-N, Test current @ 230 V … 20 A (10 ms))

    Z line impedance

    • Ranges: 0.12 Ω ... 9.99 Ω; 10.0 Ω … 99.9 Ω; 100 Ω … 999 Ω; 1.00 kΩ … 9.99 kΩ
    • Resolution: 0.01Ω; 0.1Ω; 1Ω; 10Ω
    • Accuracy: ±(5 % of reading + 5 D); ±(5 % of reading + 5 D); ± 10 % of reading; ± 10 % of reading

    Ipsc - prospective fault current

    • Ranges: 0.00 A … 0.99 A; 1.0 A … 99.9 A; 100 A … 999 A; 1.00 kA … 99.99 kA; 100 kA … 199 kA
    • Resolution: 0.01A; 0.1A; 1A; 10A; 100A
    • Accuracy: Consider accuracy of line resistance measurement

    Uln - voltage

    • Range: 0V to 550V
    • Resolution: 1V
    • Accuracy: ±(2% of reading + 2 D)

    Voltage Drop (Zref 0.00 Ω … 19.99 Ω, Test current @ 230 V … 20 A (10 ms))

    • Function: dU - voltage droo
    • Range: 0.0% ... 99.9%
    • Resolution: 0.1%
    • Accuracy: Consider accuracy of line resistance measurement (s)

    Discharging time

    t - discharging time

    • Range: 0.0s...10.0s
    • Resolution: 0.1s
    • Accuracy: ±(5% of reading + 2D)

    Up - peak voltage

    • Range: 0V to 550V
    • Resolution: 1V
    • Accuracy: ±(5% of reading + 3D)
    • Threshold voltage: 34V, 60V, 120V

    General data

    • Power supply: 110 V / 230 V AC, 50 Hz / 60 Hz
    • Max. power consumption: 300 VA (without load on mains test socket)
    • Max. load: 10 A continuous, 16 A short duration, 1.5 kW motor

    Measuring categories

    • Mains test socket, IEC test socket: CAT II / 300 V
    • TC1 test socket, (C1, C2, P1, P2, P): CAT III / 300 V

    Protection classification

    • Degree of protection: IP 54 (Closed case), IP 40 (Open case), IP 20 (Mains socket)

    Communication

    • Memory: Depends on microSD card size
    • RS-232 interfaces: Two DB9 ports RS-232-1 (PC), RS-232-2
    • INPUTs/OUTPUTs: 24 Vmax (DB9 connector, 2X)
    • USB 2.0: Standard USB Type B
    • Bluetooth: Class 2
    • Ethernet: Dynamic IP (DHCP)
    • Dimensions (L x W x H): 420 x 325 x 180 mm / 420 x 325 x 250 mm (with accessories)
    • Weight: 13.3 kg / 15.1 kg (with accessories)
  • Supplied Accessories

    • Metrel MI3325 MultiServicerXD Machinery / Electrical Safety Tester
    • HV test lead with test probe
    • HV test lead with crocodile
    • Mains cable
    • IEC test cable
    • Residual voltage test cable
    • Plug test cable
    • 3-wire test lead, 3 m
    • Continuity test lead, 2.5 m, 2 pcs
    • Test lead, red, 1.5 m
    • Test probe, 4 pcs (black, red, green, blue) • Crocodile clip, green
    • Crocodile clip, blue
    • Crocodile clip, black, 3 pcs
    • Crocodile clip, red, 3 pcs
    • Calibration certificate
    • RS-232 cable
    • USB cable
    • Short instruction manual
    • CD with instruction manual (full version) • PC SW Metrel ES Manager BASIC *
    • Protective bag for accessories **
  • Product Documents

    Product Attachments

    View FileMetrel MI3325 Datasheet    Size: (2.68 MB)
    View FileMetrel MI3325 Brochure    Size: (9.58 MB)
    View FileMetrel MI3325 Datasheet    Size: (2.68 MB)
    View FileMetrel MI3325 Brochure    Size: (9.58 MB)
  • Product Questions

    Please Sign in or Create an account to post a question.

    There are no entries.

  • Reviews

    There are currently no reviews for this product. If you have previously purchased it please leave a review using our quick and easy form to the right.

    Write Your Own Review

    Only registered users can write reviews. Please, log in or register

  • Delivery Information

    At Test-Meter.co.uk we understand the importance of a reliable delivery service when shopping online. Especially when the goods are often essential to your working day. If your goods are required by a certain date please feel free to contact us for an honest and realistic indication whether this can be met. We aim to process all orders we receive within 1 to 3 working days, however from time to time we do have an increased demand for certain products or there might be delays from the manufacturer. In such cases delivery of your equipment may be subject to a minor delay.

    We use DPD/Interlink for all larger items and Royal Mail for smaller items and accessories. With DPD/Interlink you will receive a 1 hour delivery window on the day of delivery via e-mail/text and a notification 15 minutes before arrival so you will not have to wait around all day. You can even manage your booking online and re-arrange delivery for another date or arrange the goods to be left with a neighbour of your choice.

    We also offer delivery options for goods required urgently on certain products, all which are sent by DPD/Interlink.

    Our charges for UK deliveries:

    • FREE Delivery (on select products only): typically 3-5 working days*
    • Standard Delivery at £4.95: 2-3 working days
    • Next Working Day Delivery (on select products only) at £7.50
    • Pre-Noon Next Working Day Delivery (on select products only) at £9.50*
    • Pre-10.30am Next Working Day Delivery (on select products only) at £18.50*
    • Saturday Pre-Noon Delivery (on select products only) at £14.50*
    • Sunday Pre-Noon Delivery (on select products only) at £14.50*

    *UK mainland only

    NOTE! For next working day or Saturday/Sunday delivery options the order MUST be placed no later than 3pm on the working day before delivery is required. After 3pm, please arrange with our staff before selecting a priority delivery service. Priority services are available to UK mainland residents only (this might exclude certain areas in the north of Scotland).

    Customers outside the UK:

    Test-Meter.co.uk exports to many countries all over the world. Prices for shipping vary on location and weight/dimensions. Costs are calculated for certain countries at the checkout. If your country is not included in this list please e-mail admin@test-meter.co.uk with your name, address and the items you would like to order for an accurate shipping quote or go to http://www.test-meter.co.uk/test-equipment-export for more information.

    For more information on delivery, please see our terms and conditions.