Seaward Apollo 400+ Elite Printer Kit - 5th Edition Compliant

SKU: SEAWAPOLLO400PLUSKITSC
  • Seaward Apollo 400+ with large internal memory and RCD testing
  • Comprehensive range of electrical tests updated for ET 5th Edition testing and BSEN 50699 Compliant
  • Seaward Test n Tag Elite 2 Printer and barcode scanner included
  • Print both cable wrap and appliance labels with custom barcodes
More Info
In Stock - Next Day Delivery Available
Choose Your Free Gift

For a limited time only, receive a FREE limited edition kit (worth up to £235) with every Apollo 500+ or 600+ purchase.

- Only available while stocks last.


Kit includes: 230V adaptor | Cloverleaf adaptor | 1000 Pass / 1000 Fail labels | Plug checker cards | 1 Year PATGuard 3 software licence | Guide to portable appliance testing

Seaward Apollo 400+ Elite Printer Kit (380A9906) - 5th Edition Compliant

The Seaward Apollo 400+ Elite Printer Kit has a range of different accessories that are suitable those testing the safety of electrical appliances and leads.

Updated to be fully compliant with the 5th edition of the IET Code of Practice, the Apollo 400+ includes functions such as:

  • Pass/Fail limit of 5mA for all protective & touch leakage tests in line with 5th edition
  • New Test sequence for Class 2 FE equipment

Seaward Apollo 400+ PAT Tester

The Seaward Apollo 400+ PAT Tester can perform earth bond testing, insulation resistance testing, polarity checking, touch/alternative/earth leakage measurement, load and run testing, RCD testing and power socket testing. The tester has a large internal memory with room for up to 2000 readings and there is also space for 25 pre-set test sequences. An improved interface allows the user to search the database and an external battery pack helps prevent the downtime by allowing the user to exchange batteries in the field. A full QWERTY keyboard allows the user to enter data extremely quickly.

IET 5th Edition and BSEN 50699 Compliant

Seawards Apollo 400+ PAT Tester is fully compatible with the test limits published in both the 5th Edition IET Code of Practice, and the BSEN 50699 Recurrent Tests of Electrical Equipment standard. Simply choose the guidelines you choose to work with on the PAT tester, and the tester will compare measured results with those published, providing users with a clear pass/fail indication.

Read more about the differences between the guidance published in the 5th Edition IET Code of Practice and BSEN 50699 Recurrent Tests of Electrical Equipment, by reading our blog post here.

Seaward Test n Tag Elite 2 Printer

The Seaward Test n Tag Elite 2 Printer is an excellent PAT label printer as it can produce barcoded PAT labels that also include appliance information and test results. The printer is also equally at home printing cable wrap labels as regular appliance labels.

Seaward Barcode Scanner

The Seaward Barcode Scanner can scan barcoded PAT labels which allows the user to recall all the correct appliance information in a matter of seconds. This helps record test results in a logical database without having to spend lots of time organising the saved results.

Other Accessories

A 110V adaptor is included which allows the user to test construction equipment and extension leads with the Seaward Apollo 400+ PAT Tester. All of the instruments and accessories in the kit can be stored and transported in the official carry case.

Seaward part number: 380A9906

We know the importance of getting the right instrument for the job, so we now offer a "Try Before You Buy" option on many of our products to help you make a more informed buying decision. Simply give us a call or click here to find out more.

What's In The Box?

  • Seaward Apollo 400+ PAT Tester
  • Seaward Test n Tag Elite 2 Printer
  • Seaward 2D Barcode Scanner
  • 110V Test Adaptor
  • 10 x Free Rolls of Labels for either Pro or Elite Printer (see above for details)
  • Apollo Kit Carry Case
Specification

Earth Continuity

  • Test Current: +/- 200mA DC
  • Display Range: 0.01 – 19.99Ω
  • Pass Value: User Defined

Insulation Resistance

  • Test Voltage: 500V / 250VDC @ 1mA nominal
  • Display Range: 0.01MΩ - 19.99MΩ
  • Pass Value: User Defined

IEC Lead Test

  • Test voltage: 5VAC nominal
  • Test: Live / Neutral Checks for o/c, s/c and crossed

Protective Conductor Current/Load

  • Test Voltage: Supply voltage, maximum load current 16A
  • Display Ranges: 0.01mA to 19.99mA
  • Pass Value: User Defined

Touch Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Display Range: 0.00 – 3.50mA
  • Pass Value: User defined

Load Power/Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Test Duration: Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
  • Display Range: 0.00kVA – 4.00kVA, 0.00A – 16.00A

Alternative Leakage Current

  • Test Voltages: >25VAC <50VAC
  • Display Range: 0.00mA to 19.99mA
  • Pass Value: User Defined

RCD Test

  • Test Voltage: 230V +10%, -15%
  • Test Current: 30mA / 150mA rms sinusoidal
  • Display Range: 0ms - 2000ms (30mA), 0-40ms (150mA)
  • Test method: Internal isolation to avoid tripping distribution board RCD

Power Socket Test

  • Voltage Range: 207V – 253VAC
  • Indicates configuration of voltage potential:- Line potential phase to earth, Line potential phase to neutral, Line potential neutral to earth

General

  • Memory size: 2000 records
  • Weight: 1.5kg
  • Dimensions: 230mm x 150mm x 100mm
  • Power Source: Mains or rechargeable battery pack