  • Accuracy compliant to IEC 61672 Class 1 standard
  • Capacity to simultaneously measure and analyse A, C, Z and F, S, Impulse
  • Enormous range of measurement functions
More Info
Please contact for lead time

SoundTEK ST-105 Class 1 Integrating Sound Analyser Meter

The SoundTEK ST-105 Class 1 Integrating Sound Analyser Meter is an advanced, portable sound analyser capable of measuring A, C and Z as well as F, S and Impulse. It is highly accurate and conforms to IEC 61672 Class 1 accuracy standard. The dual functionality of the device allow it to both take measurements and instantly produce statistical analyses in the 1/1 and 1/3 octave bands which saves time and space by negating the need to transfer data to a separate analysis device. This also makes it perfect for measuring and analysing background noise in the workplace, product noise and environmental noise. The ST-105 has a 24 hour automatic measuring function with adjustable intervals for ease of use.

Highly accurate readings are provided across a wide range of frequency (10Hz ~ 20KHz) and measurement (25dB ~ 140dB). The dynamic range for a single reading is 90dB and the ST-105 has Fast, Slow, PeakC+ and PeakC time weighting according to the user’s needs. A / C / Z frequency weighting helps locate noise sources and the device boasts a wide range of measurement functions. Sampling frequency is 20.8us (48KHz).

Results are displayed clearly on a backlit LCD screen alongside a realtime clock with calendar, and the USB Datalogger can store 128 records. In addition, results can be printed out on an optional-extra mini-printer. The multi-language software comes in English, Chinese, Spanish, German and Italian. 

The SoundTEK ST-105 Class 1 Integrating Sound Analyser Meter measures a truly impressive range of variables and its capacity to analyse results in real time - in addition to a multitude of adjustable settings - makes it an excellent environmental measuring device.

Key Features

  • Real-time statistical analysis
  • 24 hour measurement function
  • integral measurement
  • Simultaneously measures A, C, Z and F, S, Impulse
  • Measurement functions: Lxyp, (Lxyi), Lxeq,1s, Lxeq, T, LAE, E,Cpeak+, Cpeak- , LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT, Laeq(20Hz~200Hz)
  • USB Datalogger capable of storing 128 records
  • Real time clock and calendar
  • Sampling frequency: 20.8us (48KHz)
  • Wide ranges of frequency (10Hz ~ 20KHz) and measurement (25dB ~ 140dB)
  • 90dB dynamic range
  • Fast, Slow, Impulse, PeakC+, PeakC- time weightings
  • A, C, Z frequency weighting
  • Optional mini-printer 
  • Software in 5 languages (English / Chinese / Spanish / German / Italian)

SoundTEK Meter Comparison Chart

  ST-105 ST-106 ST-107S ST-109
IEC 61672-1-2002 Class 1  
IEC 61672-1-2002 Class 2      
Datalogging
128 Records Storage      
37,000 Records Storage    
24H Measurement
1/1 Octave      
1/3 Octave      
Real time analysis      
A/C/Z
F/S/Impulse    
24H Measurement
Micro-SD Slot    
Compatible with SoundTEK ST-120 Class 1 Sound Calibrator (optional extra)

What's In The Box?

  • SoundTEK ST-105 Sound Analyser Meter
  • 4 x AA LR6 1.5V Batteries
  • 2 x USB to mini-USB cables
  • Calibration certificate
  • Instruction manual for SoundTEK ST-105 Sound Analyser Meter
  • SoundTEK case
  • Carry strap for case;
  • Wind muffler
  • 8GB USB memory stick
Specification
  • Display refresh: 1Hz for value, 10Hz for graph
  • Resolution: statistic is 0.1dB, OCT and 1/3 OCT is 0.01dB
  • Frequency range: 10Hz ~ 20KHz ±0.2dB, 1Hz ~ 23KHz (±1.0dB)
  • Range gain: -10dB, 0db, 10dB, 20dB, 30dB, 40dB
  • Range control error: ≤0.1dB
  • Self-generated noise voltage: <4µV (1Hz ~ 23KHz linear) (Short circuit with 50Ω resistor)
  • Measuring voltage range: 15µV ~ 10V (RMS)
  • Level linear range: >90dB
  • Time weighting: Parallel (simultaneous) F, S, I, PeakC+, PeakC-
  • Frequency weighting: Parallel (simultaneous) A, C, Z. Realised by digital filtering.
  • A/D bits: 24 bits
  • Anti aliasing filter: cut off frequency is 23.5Hz and stop band attenuation is 100dB
  • Contrast adjustment: 64-class adjustable
  • Integrated time: 1.s-24H, set in a given range or randomly
  • Data storage: can store analysis result, 24h measuring result and integrated measuring result (max. 128 groups. Result can only be stored in flash disk that comes with analyser)
  • Internal clock: error <1 minute per month
  • Stores up to 256 calibration records
  • Starting time: <10s
  • Background noise: <13dB (A), 15 dB (C), 25dB (Z). Note: Take 20 µPa as reference 0dB. The below are the same. Input 15 pF capacitor is short circuit to the END.
  • Total noise: <18dB (A), 23dB (C), 28dB (Z)
  • Measuring ranges: 25~140dB (A) 30-140dB (C), 35~140dB (Z). Note microphones with different sensitivities have different measuring ranges.
  • Peak C sound level measuring range: 50~143dB
  • Range display: 0~90, 10~100, 20~110, 30~120, 40~130, 50~140 dB