TPI 717R Flue Gas Analyser Kit 2

SKU: TPI717RKIT2
  • Two CK21M pipe clamp probes measure temperatures between -50˚C and 250˚C
  • Measurement/calculation of O2, CO, CO2, temperature, pressure, efficiency and more
  • Timed tightness/let by test and timed CO ambient build-up test
More Info
Discontinued

TPI 717R Flue Gas Analyser Kit 2

The TPI 717R Flue Gas Analyser Kit 2 consists of the flue gas analyser itself alongside an A740 Infrared Printer and two CK21M pipe clamp temperature probes with a temperature range of -50˚C to 250˚C. The analyser can take measurements for oxygen, carbon monoxide, temperature and pressure in flue gas which thereby permits calculation of carbon dioxide content, CO/CO2 ratio, efficiency and excess air. A comprehensive set of measurement parameters are rounded off by timed tightness/let by testing and timed ambient CO build-up measurement. Ambient CO is assessed using a GK11M air probe.

Results are clearly displayed on the TPI 717R’s backlit digital screens which also flashes up with a countdown to the next service. 100 different data sets can be saved to the internal memory with accompanying time and date stamps. Infrared technology allows result sets to be printed with a serial number on the A740 Printer using wireless communication. Standard software on the analyser creates an intuitive operating system, simplified test process and provides speedy calculated values.

The standard flue gas probe included in the TPI 717R Kit 2 has a dust filter and water trap filter to prevent damaging ingress into the analyser. The instrument comes with a six-year warranty (subject to regular approved servicing) whilst rubber casing also helps protect it from the elements. One charge of the battery powers the analyser for 6 hours and, overall, it provides comprehensive testing capabilities in a hardy package with several useful accessories.

Key Features

  • Oxygen measurement: 0 to 25%
  • Carbon monoxide measurement: 10000ppm
  • Carbon dioxide calculation: 0 to 25%
  • CO/CO2 ratio calculation
  • Temperature measurement: -40˚C to 800˚C
  • Pressure measurement: -150mBar to +150mBar
  • Excess air and efficiency calculation
  • Multi-fuel combustion analysis
  • Timed tightness/let by
  • Timed CO build up in ambient air
  • 100 data sets in internal memory
  • Countdown to next service
  • TPI A740 IR Printer
  • 2 x CK21M pipe clamp temperature probes
  • 6-year warranty

We offer the following kits for the TPI 717R:

  Standard Kit Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Oil Kit
TPI 717R Flue Gas Analyser
A740 IR Printer  
2 x CM21K Temperature Pipe Clamp Probes      
CPA1 Probe Set          
TPI 719 Gas Leak Detector          
Oil filter            
Smoke Pump            

 

TPI 717R Kit Featured Contents

  • TPI 717R Flue Gas Analyser

TPI 717R Kit 1 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer

TPI 717R Kit 2 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps

TPI 717R Kit 3 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set

TPI 717R Kit 4 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • TPI 719 Gas Leak Detector

TPI 717R Kit 5 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set
  • 719 Gas Leak Detector

TPI 717R Oil Kit Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • Smoke pump
  • Oil filter

What's In The Box?

  • TPI 717R Flue Gas Analyser
  • Flue Temperature Probe
  • ‘K’-Type Temperature Air Probe GK11M
  • In-Line Water Trap Bowl Filter Complete
  • Mini Pump Protection Filter Assembly
  • Battery Charger
  • Protective Boot
  • Soft Carrying Case
  • Exhaust Spigot
  • TPI A740 IR Printer
  • 2 x TPI CK21M Pipe Clamp Temperature Probes
Specification

Carbon Monoxide (CO) Measurement

  • Range: 0 to 10,000 ppm
  • Resolution: 1 ppm
  • Accuracy: <20 ppm : ± 3ppm; >100 ppm : ± 5%

Oxygen (O2) Measurement

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: ±0.3% 

Carbon Dioxide (CO2)

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: Calculated

Ratio (CO/CO2)

  • Range: 0 to 0.999
  • Resolution: 0.001
  • Accuracy: Calculated 

Gross/Net Efficiency

  • Range: 0 to 100%
  • Resolution: 0.1%

Temperature Measurement

  • Range: -40° to 800° C (-40° to 1472° F)
  • Resolution: 1°C or F
  • Accuracy (K-type): ±0.3%, ±1°C or ±2°F

Draft/Pressure Measurement

  • Selectable Ranges: mBar,kPa, and inH2O
  • Range: -150 mBar to +150 mBar
  • Resolution: 0.01mBar
  • Accuracy: ±0/5% fsd 

Instrument Specifications

  • Operating Temperature Range: -10° to 50°C
  • Battery: Rechargeable Ni-MH, >6 Hour Life
  • Charger Input Voltage: 115V or 230V; 50/60 Hz AC
  • Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood (Dry), Bagasse, Wood Pellet
  • Display Backlit: LCD
  • Data Storage: 100 sets
  • Time & Date: 24 Hour Clock
  • Dimensions: 200 x 90 x 60mm
  • Weight: 500g
  • Conforms To: EN50379 / BS7967

CK21M Pipe Temperature Clamp

  • Max diameter: 30mm
  • Lead length: 1.5m
  • Measurement range: -50˚C to 250˚C
Label Type Size Download
pdf TPI 717R Datasheet pdf 414.1 KB Download