TPI 717R Flue Gas Analyser Kit 4

SKU: TPI717RKIT4
  • Contains a TPI 719 Gas Leak Detector for sensing different hydrocarbon gases
  • Measures O2, CO, CO2, efficiency, excess air, temperature and pressure
  • Internal memory with room for 100 different data sets
More Info
Discontinued

TPI 717R Flue Gas Analyser Kit 4

Safety is at the heart of the TPI 717R Flue Gas Analyser Kit 4 as it contains a TPI 719 Gas Leak Detector which builds on the safety features of the TPI 717R Flue Gas Analyser. The TPI A740 infrared printer and two CK21M pipe clamp temperature probes also facilitate quick, in-depth inspections.

The TPI 717R can measure a range of important parameters including oxygen content, carbon monoxide level, temperature and pressure. Differential temperature and pressure modes allow the user to compare values on input and output pipes for more sophisticated analysis. In addition to normal measurement parameters, the analyser can also perform timed tightness/let by tests as well as measuring ambient CO and assessing CO build up in a room. Finally, it is also possible to calculate carbon dioxide levels, CO/CO2 ratio, efficiency and excess air.

The TPI 719 Gas Leak Detector can sense several different organic gases and has a sensitivity of just 30ppm for methane. It gives both visual and audible warning of the presence of gas, thus making sure that the user is always aware if a hydrocarbon gas is present. This supplements the carbon monoxide detection function on the TPI 717R which keeps the device on when dangerous CO concentrations are present.

The TPI 717R displays results on its backlit digital screen alongside the time and date and a serial number. Up to 100 data sets with time stamps and serial numbers can be saved to the analyser’s internal memory and the infrared printer can wirelessly communicate with the analyser to print out results on site. A countdown to the next service due date is flashed up on screen to help the user keep the device maintained.

The flue gas probe supplied with the TPI 717R Kit 4 has water and dust filters to prevent harmful ingress into the analyser and it is further protected by rubber boot casing. TPI provide a six-year warranty with the analyser - subject to regular servicing - and one charge provides energy for six hours of operation.

Key Features

  • Oxygen range: 0 to 25%
  • Carbon dioxide range: 0 to 25%
  • Carbon monoxide range: 0 to 10000ppm
  • CO/CO2 ratio
  • Efficiency/excess air calculation
  • Differential temperature and pressure
  • Timed tightness and let by testing
  • Ambient CO build up test
  • TPI 719 Gas Leak Detector 
  • TPI A740 IR Printer
  • 2 x CK21M pipe clamp temperature probes

We offer the following kits with the TPI 717R:

  Standard Kit Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Oil Kit
TPI 717R Flue Gas Analyser
A740 IR Printer  
2 x CM21K Temperature Pipe Clamp Probes      
CPA1 Probe Set          
TPI 719 Gas Leak Detector          
Oil filter            
Smoke Pump            

 

TPI 717R Kit Featured Contents

  • TPI 717R Flue Gas Analyser

TPI 717R Kit 1 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer

TPI 717R Kit 2 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps

TPI 717R Kit 3 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set

TPI 717R Kit 4 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • TPI 719 Gas Leak Detector

TPI 717R Kit 5 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set
  • 719 Gas Leak Detector

TPI 717R Oil Kit Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • Smoke pump
  • Oil filter

What's In The Box?

  • TPI 717R Flue Gas Analyser
  • Flue Temperature Probe
  • ‘K’-Type Temperature Air Probe GK11M
  • In-Line Water Trap Bowl Filter Complete
  • Mini Pump Protection Filter Assembly
  • Battery Charger
  • Protective Boot
  • Soft Carrying Case
  • Exhaust Spigot
  • TPI A740 IR Printer
  • 2 x TPI CK21M Pipe Clamp Temperature Probes
  • TPI 719 Gas Leak Detector
Specification

Carbon Monoxide (CO) Measurement

  • Range: 0 to 10,000 ppm
  • Resolution: 1 ppm
  • Accuracy: <20 ppm : ± 3ppm; >100 ppm : ± 5%

Oxygen (O2) Measurement

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: ±0.3% 

Carbon Dioxide (CO2)

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: Calculated

Ratio (CO/CO2)

  • Range: 0 to 0.999
  • Resolution: 0.001
  • Accuracy: Calculated 

Gross/Net Efficiency

  • Range: 0 to 100%
  • Resolution: 0.1%

Temperature Measurement

  • Range: -40° to 800° C (-40° to 1472° F)
  • Resolution: 1°C or F
  • Accuracy (K-type): ±0.3%, ±1°C or ±2°F

Draft/Pressure Measurement

  • Selectable Ranges: mBar,kPa, and inH2O
  • Range: -150 mBar to +150 mBar
  • Resolution: 0.01mBar
  • Accuracy: ±0/5% fsd 

Instrument Specifications

  • Operating Temperature Range: -10° to 50°C
  • Battery: Rechargeable Ni-MH, >6 Hour Life
  • Charger Input Voltage: 115V or 230V; 50/60 Hz AC
  • Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood (Dry), Bagasse, Wood Pellet
  • Display Backlit: LCD
  • Data Storage: 100 sets
  • Time & Date: 24 Hour Clock
  • Dimensions: 200 x 90 x 60mm
  • Weight: 500g
  • Conforms To: EN50379 / BS7967

TPI 719 Combustible Gas Detector

  • Gases detected: Methane, Natural Gas, Gasoline, Diesel, Propane (LPG), Butane, Kerosene
  • Sensitivity: 30ppm (CH4)
  • Sensor Type: Low power semiconductor
  • Probe Length: 16”
  • Leak Indication: Audio / Visual
  • Adjustable Tic Rate: Yes
  • Battery: “C” cell (2)
  • Weight: 500g
Label Type Size Download
pdf TPI 717R Datasheet pdf 414.1 KB Download