TPI 717R Flue Gas Analyser Kit

SKU: TPI717R
  • Measurement of O2, CO, temperature and pressure
  • Timed tightness and CO ambient build-up tests
  • Calculation of CO2, efficiency, tightness, excess air and CO/CO2 ratio
More Info
Discontinued

TPI 717R Flue Gas Analyser Kit

The TPI 717R Flue Gas Analyser is a versatile flue gas analyser that can measure oxygen, carbon monoxide, differential flue temperature and pressure. This allows calculation of efficiency, excess air content, CO2 and CO/CO2 ratio as well as tightness and let by calculation. Advanced measurement features include timed let by and tightness and timed CO build-up measurement, thus making use of the ambient CO function. The analyser can adapt to different fuels including oil, coal and gas.

Results are displayed on the TPI 717R’s digital, backlit screen and this also flashes up with a message counting down to the next calibration due date when the instrument is turned on. Up to 100 result sets with date-and-time stamps can be saved to the internal memory and then accessed via the simple button interface.

An integrated magnet allows the TPI 717R to stick on vertical metal surfaces during inspections whilst exchangeable water trap bowl and pump protection filters help prevent corrosion of the analyser. The analyser is guaranteed for six years under warranty (with regular servicing) and also has a protective boot cladding for further protection. One charge of the battery powers the instrument for six hours and a soft carry case is provided for practicality. Overall, it is an extremely useful and adaptable analyser for anyone working on combustion systems.

TPI part number: 717R-Kit

Key Features

  • O2 measurement: 0 to 25%
  • CO measurement: 0 to 10000ppm
  • CO2 calculation: 0 to 25%
  • CO/CO2 ratio: 0 to 0.999
  • Efficiency: 0 to 100%
  • Temperature: -40˚C to 800˚C
  • Pressure: -150 mBar to + 150mBar
  • Excess air calculation
  • Multi-fuel analysis
  • Integrated magnet
  • Timed tightness/let by
  • Timed ambient CO build up
  • 100 data sets on internal memory
  • Countdown to next calibration
  • 6-year warranty

We offer the following kits for the TPI 717R:

  Standard Kit Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Oil Kit
TPI 717R Flue Gas Analyser
A740 IR Printer  
2 x CM21K Temperature Pipe Clamp Probes      
CPA1 Probe Set          
TPI 719 Gas Leak Detector          
Oil filter            
Smoke Pump            

 

TPI 717R Kit Featured Contents

  • TPI 717R Flue Gas Analyser

TPI 717R Kit 1 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer

TPI 717R Kit 2 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps

TPI 717R Kit 3 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set

TPI 717R Kit 4 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • TPI 719 Gas Leak Detector

TPI 717R Kit 5 Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Set
  • 719 Gas Leak Detector

TPI 717R Oil Kit Featured Contents

  • TPI 717R Flue Gas Analyser
  • TPI A740 IR Printer
  • Smoke pump
  • Oil filter

What's In The Box?

  • TPI 717R Flue Gas Analyser
  • Flue Temperature Probe
  • ‘K’-Type Temperature Air Probe GK11M
  • In-Line Water Trap Bowl Filter Complete
  • Mini Pump Protection Filter Assembly
  • Battery Charger
  • Protective Boot
  • Soft Carrying Case
  • Exhaust Spigot
Specification

Carbon Monoxide (CO) Measurement

  • Range: 0 to 10,000 ppm
  • Resolution: 1 ppm
  • Accuracy: <20 ppm : ± 3ppm; >100 ppm : ± 5%

Oxygen (O2) Measurement

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: ±0.3% 

Carbon Dioxide (CO2)

  • Range: 0 to 25%
  • Resolution: 0.1%
  • Accuracy: Calculated

Ratio (CO/CO2)

  • Range: 0 to 0.999
  • Resolution: 0.001
  • Accuracy: Calculated 

Gross/Net Efficiency

  • Range: 0 to 100%
  • Resolution: 0.1%

Temperature Measurement

  • Range: -40° to 800° C (-40° to 1472° F)
  • Resolution: 1°C or F
  • Accuracy (K-type): ±0.3%, ±1°C or ±2°F

Draft/Pressure Measurement

  • Selectable Ranges: mBar,kPa, and inH2O
  • Range: -150 mBar to +150 mBar
  • Resolution: 0.01mBar
  • Accuracy: ±0/5% fsd 

Instrument Specifications

  • Operating Temperature Range: -10° to 50°C
  • Battery: Rechargeable Ni-MH, >6 Hour Life
  • Charger Input Voltage: 115V or 230V; 50/60 Hz AC
  • Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood (Dry), Bagasse, Wood Pellet
  • Display Backlit: LCD
  • Data Storage: 100 sets
  • Time & Date: 24 Hour Clock
  • Dimensions: 200 x 90 x 60mm
  • Weight: 500g
  • Conforms To: EN50379 / BS7967
Label Type Size Download
pdf TPI 717R Datasheet pdf 414.1 KB Download