Kane 451 Plus Combustion Flue Gas Analyser Kit

SKU: KANE251PLUSKIT
  • Includes the KANE451plus, an infrared printer, carry case & more
  • Offers direct CO2 measurement, pressure testing & a long-life high-range CO sensor
  • Ideal for use with biomass appliances, natural gas, light oil, propane, butane and more
More Info
Discontinued

Kane 451 Plus Combustion Flue Gas Analyser Kit

*This product has now been discontinued.*

Complete with an infrared printer and carry case, the Kane 451 Plus Combustion Flue Gas Analyser Kit is ideal for the installation or servicing of oil boilers and for anyone working with Biomass appliances.

Providing direct CO2 measurement, pressure testing, a long-life high-range CO sensor and a range of calculated results, the Kane 451plus comes with a range of accessories including an infra-red linked printer, allowing test results to be quickly be printed on-site.

Suitable for engineers who install and service oil/gas boilers or biomass appliances, the Kane 451 Plus Combustion Flue Gas Analyser Kit is a versatile and cost-effective bundle.

What's In The Box?

  • Analyser
  • KMCP2 flue probe
  • 4 x NiMh
  • Rechargeable batteries
  • Charger
  • 2 x pressure fittings
  • KANE IRP-2 manual
  • Carry case
Specification

Flue Temperature

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2.0°C, ±0.3% reading

Inlet Temperature (Internal Sensor)

  • Range: 0-50°C
  • Resolution: 0.1°C
  • Accuracy: ±2.0°C, ±0.3% reading

Inlet Temperature (External Sensor)

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2.0°C, ±0.3% reading

Oxygen (Calculated)

  • Range: 0-21%
  • Resolution: 0.1%
  • Accuracy: ±0.3%

Carbon Monoxide (Using dry gases at STP)

  • Range: 0-20ppm, 21-4,000ppm nom, 4,001-10,000ppm, 20,000ppm max for 15 mins
  • Resolution: 1ppm
  • Accuracy: ±3ppm, ±5% of reading, ±10% of reading

Carbon Dioxide (Using dry gases at STP)

  • Range: 0-20%
  • Resolution: 0.1%
  • Accuracy: ±0.3% volume

Calculated Efficiency (Net or Gross)

  • Range: 0-99.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% of reading

Calculated Efficiency High (C)

  • Range: 0-119.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% of reading

Calculated Excess Air

  • Range: 0-250%
  • Resolution: 0.1%
  • Accuracy: ±0.2% of reading

Calculated CO/CO2 ratio

  • Range: 0-0.999
  • Resolution: 0.0001
  • Accuracy: ±5% of reading

Pressure (Differential): Nominal range ±1600mbar

  • Range: ±1mbar
  • Resolution: Maximum 0.001mbar
  • Accuracy: ±0.05mbar

Pressure (Differential): Maximum over range without damage to sensor is ±800mbar

  • Range: ±160mbar
  • Resolution: < 25mbar
  • Accuracy: ±3% of reading

General

  • Pre-programmed Fuels:Natural gas, Propane, Butane, LPG, Light Oils (28/35 sec), Wood Pellets plus 3 User Fuels
  • Storage Capacity: 99 Combustion tests, 20 Pressure tests, 20 Tightness tests, 20 Temperature tests, 20 Room CO tests
  • Ambient Operating Range: 0°C to ±45°C - 10% to 90% RH non-condensing
  • Battery Type / Life: 4 AA cells - > 8 hours using Alkaline AA cells
  • Chargers (optional): 220v charger, for NiMH batteries only
  • Weight:0.8kg handset with protective cover
  • Handset (Dimensions): 200 x 45 x 90mm
  • Probe (Dimensions): 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m long neoprene hose. Type K thermocouple.