Kane 255 Combustion Flue Gas Analyser Kit

SKU: KANE255KIT
  • Includes KANE255, an infrared printer, carry case & more
  • A truly versatile and cost-effective kit
  • Ideal for engineers who install/service oil or gas boilers
More Info
£506.40 £422.00
Discontinued

Kane 255 Combustion Flue Gas Analyser Kit

This product has now been discontinued and replaced with the Kane 258 Combustion Flue Gas Analyser Kit.

Featuring the handheld KANE255, an infrared printer and a carry case, the Kane 255 Combustion Flue Gas Analyser Kit is the ideal kit for on-site flue gas testing.

Capable of CO2, CO and temperature measurement and a range of calculated results, the Kane 255 is more than up to the challenge when it comes to on-site flue gas testing and, despite it’s low cost, doesn’t compromise of performance.

Perfect for engineers who install/service oil or gas boilers, the Kane 255 Combustion Flue Gas Analyser Kit is truly versatile and cost-effective, coming complete with an infra-red linked printer, allowing test results to be quickly be printed on-site.

What's In The Box?

  • KANE 255 Combustion Flue Gas Analyser 
  • Charger
  • Batteries
  • KMCP2
  • Test report
  • Manual
  • KANE IRP-2 Printer
  • Case
Specification

Flue Temperature

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Inlet Temperature (Internal Sensor)

  • Range: 0-50°C
  • Resolution: 0.1°C
  • Accuracy: ±1°C, ±0.3% reading

Inlet Temperature (External Sensor)

  • Range: 0-600°C
  • Resolution: 0.1°C
  • Accuracy: ±2°C, ±0.3% reading

Oxygen (Using dry gases at STP)

  • Range: 0.21%
  • Resolution: 0.1%
  • Accuracy: ±0.3%

Carbon Monoxide (H2 compensated)

  • Range: 0-20ppm (1), 21-2,000ppm nom (2) and 4,000ppm max for 15 mins (3)
  • Resolution: 1ppm
  • Accuracy: ±0.3ppm (1), ±3ppm (2) and ±5% of reading (3)

Carbon Dioxide (Using dry gases at STP)

  • Range: 0-20%
  • Resolution: 0.1%
  • Accuracy: ±0.3% volume

Calculated Efficiency (Net or Gross)

  • Range: 0-99.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Efficiency High (C)

  • Range: 0-119.9%
  • Resolution: 0.1%
  • Accuracy: ±1.0% reading

Calculated Excess Air

  • Range: 0-250%
  • Resolution: 0.1%
  • Accuracy: ±0.2% reading

Calculated CO/CO2 ratio

  • Range: 0-0.999
  • Resolution: 0.0001
  • Accuracy: ±5% reading

General

  • Pre-programme fuels: Natural gas, Light Oil, Propane, Butane, LPG, Wood Pellets.
  • Weight: 1kg / 2.2lb
  • Handset Dimensions: 200mm / 7.9" x 45mm / 1.8" x 90mm / 3.5"
  • Probe Dimensions: L300mm / 11.8" x Dia 6mm / 0.25" with 200mm / 7.8" long stainless steel shaft, type K thermocouple and 3m / 6ft long neoprene hose
  • Ambient Operating Range: ±0°C to ±40°C / 32-104°F, 10% to 90% RH non-condensing
  • Storage Capacity: 20 sets of test results in volatile memory
  • Battery Life: 4AA cells > 8 hours using Alkaline AA cells
  • Charger (optional): 110Vac/220 Vac nominal for NMiH batteries only, 12V in vehicle charger for NMiH batteries only