Kewtech EZYPAT Plus Contractors PAT Testing Kit

SKU: KEWTEZYPATPLUSCONKIT
  • Selectable 250V and 500V insulation resistance testing.
  • Large backlit LCD display with clear PASS, FAIL and PROGRESS indications
  • Supplied as a complete contractor's kit with labels, certificates, accessories and a carry bag
More Info

£475.00 (ex VAT)
£570.00 (inc VAT)

In Stock - Available Next Day

Kewtech EZYPAT Plus Contractors PAT Testing Kit

The Kewtech EZYPAT Plus Contractors PAT Testing Kit is a practical solution for contractors who need a portable PAT tester for routine electrical safety testing of appliances, power tools and extension leads. Featuring the battery-powered Kewtech EZYPAT Plus PAT tester, this kit combines comprehensive PAT testing capabilities with 230V and 110V run and leakage testing. Its compact design makes it well suited to mobile testing environments, while the included labels, certificates and accessories provide everything needed to identify tested equipment and maintain clear records.

The EZYPAT Plus allows contractors to carry out PAT testing without relying on a mains supply for standard testing functions. When connected to a suitable 230V or 110V supply, it can also perform run and leakage tests, allowing equipment to be assessed under normal operating conditions. This is particularly useful for handheld appliances and power tools, helping users verify correct operation alongside routine electrical safety checks.

The tester also provides a range of core functions required for practical PAT testing, such as a 200mA continuity test current that is safe for use on IT equipment. Where required, the continuity test duration can be extended to five seconds. Insulation resistance testing is available at both 500V and 250V, with the lower test voltage suitable for testing surge-protected extension leads and sensitive equipment. Additional functions include substitute leakage testing, polarity checking and a test lead null feature that compensates for lead resistance to improve measurement accuracy.

Testing results are easy to interpret on the backlit LCD display, which provides clear visual status indications. A flashing green display shows a PASS result, while red shows FAIL and blue confirms that a run test is in progress. Clearly labelled controls provide automatic test sequences for Class I appliances, Class II appliances and extension leads, helping streamline repetitive testing work.

The EZYPAT Plus is also compatible with the KEWPAT app, giving users the option to store test information and generate reports digitally. This can make it easier to keep testing records organised and produce documentation for completed work. The tester can perform approximately 1,400 to 1,500 tests from a single set of batteries, helping to minimise downtime during busy testing schedules. The Contractors Kit includes a range of accessories to help users get started straight away, including an IEC adaptor, PAT certificate, two rolls of 500 PASS labels, 250 PASS wrap labels, 200 FAIL labels and 250 Tuff Tag Cable Wrap Labels. A dedicated test-meter kit bag keeps the tester and accessories together, making the complete setup easier to transport from one job to the next.

PAT Testing Kit Comparison Guide

 

Small Business Kit

Contractors Kit

Landlords kit

Maintenance kit

Industrial kit

Test-Meter Kit Bag

 ✔

x 2

PAT Register Book

 ✔

PAT Certificate Pad

 ✔

Test Meter PRO TMP989 230V 13A Socket Tester

 

   

IEC Cloverleaf Adaptor

   

   

IEC Adaptor Kit

 ✔  

500 Pass labels

x 2

 x 2

x 2

x 2

 x 2

250 Pass Wrap labels

 ✔

x 2

x 2

x 2

200 Fail labels

 ✔

250 Tuff Tag Cable Wrap Labels

   ✔  

16A 110V Appliance Adaptor and Extension Lead Adaptor

     

PL13 230V 13A Plug Lockout & Padlock

   

 

16A 230V Appliance Adaptor and Extension Lead Adaptor

     

32A 110V Appliance Adaptor and IEC Extension Lead Adaptor

       

32A 230V Appliance Adaptor and Extension Lead Adaptor

       

16A & 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors

       

Key Features

  • Battery-powered PAT tester for portable, on-site testing
  • 230V and 110V run and leakage testing capability
  • 200mA earth continuity test suitable for testing IT equipment
  • Selectable 250V and 500V insulation resistance testing
  • Five-second continuity test option for detailed earth bond testing
  • Substitute leakage testing for sensitive equipment
  • Polarity checking function for appliances and extension leads
  • Test lead null feature to improve measurement accuracy
  • Automatic test sequences for Class I, Class II and extension leads
  • Large backlit LCD display with clear PASS, FAIL and PROGRESS indications
  • Compatible with the KEWPAT app for digital record keeping and reporting
  • Long battery life, providing approximately 1,400 to 1,500 tests per set of batteries
  • Supplied as a complete contractor's kit with labels, certificates, accessories and a carry bag

What's In The Box?

  • Kewtech EZYPAT Plus
  • Test-meter kit bag
  • PAT certificate pad
  • IEC adaptor
  • 2 x 500 labels
  • 250 pass wrap labels
  • 200 fail labels
  • 250 Tuff Tag Cable Wrap Labels
Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)

Please see our terms and conditions for full details of TM Care & Protect.

Everything you’re likely to require for the next 3 or 5 years:

✅ Annual calibrations included
No further calibration costs for either 3 or 5 years

✅ Free collection and return for annual calibration
No hidden postage costs when it’s time for calibration

✅ ‘Zero-Downtime’ for the life of your care plan
Free loan equipment should your purchase ever need sending away for repair

✅ Anti-theft protection 
Each care plan includes a SmartTrace Forensic Marking kit that acts as a deterrent for your test equipment and other tools

✅ Instrument cleaning kit
Cleaning kit included with each TM Care & Protect plan

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Ensures complete reliability, minimised downtime and peace of mind. TM Care & Protect packages include:

✅ Annual Calibration
No further calibration costs for up to 5 years.

✅ Zero Unplanned Downtime
In case of any unforeseen repairs, we provide FREE loan instruments so you can continue working.

✅ Theft Deterrent Kit
Each care plan includes a SmartTrace forensic marking kit: The UK's most powerful theft deterrent. Use on your test equipment, van and tools.

✅ No Shipping Cost
Includes collection and return deliveries when it's time for calibration.

✅ Instrument Cleaning Kit
Avoid preventable issues by keeping your test equipment clean.

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Please see our terms and conditions for full details of TM Care & Protect.