Martindale HPAT600/2 Test Kit A

SKU
MART600KITA
Starter kit with everything required for entry level users to start low volume appliance testing in schools, colleges and offices.
More Info

As low as inc VAT £418.80 ex VAT £349.00

In Stock - Available Next Day
Martindale HPAT600/2 PAT Tester Kit A
Martindale HPAT600/2 Test Kit A

In stock

Customise Martindale HPAT600/2 Test Kit A
1 x Martindale HPAT600/2 PAT Tester   + inc VAT £0.00 ex VAT £0.00

* Required Fields

Summary

    Product Details

    Martindale HandyPAT 600 Test Kit A

    The Martindale HandyPAT 600 PAT testing Kit A meets the requirements of novice and low volume users to provide a PAT testing kit complete with microwave leakage options.

    Martindale HPAT600 Key Features

    • Manual and automatic modes for novice and expert users
    • Results storage for up to 200 tests
    • Dual insulation test at both 250V and 500V
    • Low current earth bond test ideal for sensitive IT equipment
    • Clear Pass/Fail indication and test result value

    The Handy PAT 600 portable appliance tester offers improved functionality with auto test mode, data storage, dual voltage insulation test and user adjustable pass and fail limits (ideal when testing longer extension leads).

    The Martindale HandyPAT 600 PAT Tester is capable of storing test results for up to 200 appliances which can be quickly reviewed on the screen and used when filling out PAT certificates and log books. In addition the Martindale HPAT600 uses rechargeable batteries and is supplied with a mains charger and in-car charger, allowing the unit to be recharged when not in use and even when travelling between sites.

    Martindale HandyPAT 600 Kit A Includes:

    • Martindale Handy PAT 600 PAT Tester
    • Microwave Leakage Detector
    • 150 Microwave Emission Labels
    • PAT Certificate Pad
    • PAT Register Book w/ Frequency of Inspection
    • IEC Clover Leaf Adaptor
    • Martindale CP501 Socket Tester
    • 1000 Pass Labels
    • 200 Fail Labels
    • 250 PassWrap Cable Labels
    • Earth Bond Lead
    • 230V Extension Lead Adaptor
    • Mains Lead
    • In-Car Charger
    • 6 x Rechargeable Batteries
    • HandyPAT 600 Carry Case

    Martindale HandyPAT 600 Kit Comparisons

    Kit AKit BKit CKit D
    MartindaleHandyPAT 600 PAT Tester
    Microwave Leakage Detector
    150 Microwave Emissions Labels
    PAT Certificate Pad
    PAT Register Book w/ Frequency of Inspection
    IEC Clover Leaf Adaptor
    Martindale CP501 Check Plug
    1000 Pass Labels
    200 Fail Labels
    250 PassWrap Cable Labels
    250 Tuff Tag Cable Labels
    Earth Bond Test Lead
    Mains Lead
    230V Extension Lead Adaptor
    110V Appliance Adapter
    110V Extension Lead Adaptor
    Rechargeable Batteries
    In-Car Charger
    HandyPAT 600 Carry Case
    Portable Appliance Tester Kit Carry Case
    What's In The Box?
    • Martindale HPAT600/2 PAT Tester
    • Microwave Leakage Detector
    • 150 Microwave Emission Labels
    • PAT Certificate Pad
    • PAT Register Book w/ Frequency of Inspection
    • IEC Clover Leaf Adaptor
    • Martindale CP501 Socket Tester
    • 1000 Pass Labels
    • 200 Fail Labels
    • 250 PassWrap Cable Labels
    • Earth Bond Lead
    • 230V Extension Lead Adaptor
    • Mains Lead
    • In-Car Charger
    • 6 x Rechargeable Batteries
    • HandyPAT 600 Carry Case
    More Information
    Specification

    Earth Bond Test (IT Safe)

    • Test Current: 200mA DC
    • Test Voltage: 4V DC
    • Range: 0 - 19.99Ω
    • Resolution: 0.01Ω
    • Default Pass Value: 0.1Ω
    • User Selectable Pass Value: 0.1Ω to 0.9Ω in 0.1Ω steps

    Insulation Resistance

    • Test Voltage: 500V: >500V DC at 1mA, 250V: >250V DC at 1mA
    • Default Pass Value: Class I - 1MΩ, Class II - 2MΩ
    • User Selectable Pass Value: 0.3MΩ to 1MΩ in 0.1Ω steps, or 1MΩ to 10MΩ in 1MΩ steps

    IEC & Extension Lead Test

    • Earth Continuity: 200mA DC
    • Insulation Test: 500V DC
    • Wiring Test: Live, Neutral Continuity & Polarity

    Fuse Test

    • Test Voltage: 4V DC
    • Test Current: 200mA DC
    • Pass Level: >2mA

    Simulated Load Test

    • Test Voltage: 4V DC
    • Test Current: 200mA DC
    • Accuracy: +/- (5% reading + 2 digits, referenced up to 230V)