Chauvin Arnoux F65 True RMS Earth Leakage Current Clamp

SKU: CHAUF65
  • True RMS measurement on leakage currents between 0 and 100A
  • 70dB immunity to eddy current and anti-harmonic filter
  • Measures voltage, frequency and resistance
More Info
Typically ships in 5-7 working days

Chauvin Arnoux F65 True RMS Earth Leakage Current Clamp

The Chauvin Arnoux F65 True RMS Earth Leakage Current Clamp is an ideal clamp meter for measuring earth leakage current thanks to its 28mm jaw. It can measure AC current from 0 to 100A with a resolution of 10µA and its true RMS capabilities help ensure accuracy when working on AC outputs. A high immunity to eddy currents (70dB) means that there is little interference from neighbouring conductors whilst a harmonics filter is very useful for advanced fault finding on complicated systems.

Standard multimeter functions are included on the Chauvin Arnoux F65. These include AC/DC voltage measurement up to 600V, resistance measurement up to 1kΩ, continuity testing and frequency measurement up to 1kHz.

The Chauvin Arnoux F65 has a backlit LCD screen with a zero and hold button so test lead resistance can be cancelled out and readings can be frozen on screen. Differential measurement and maximum recording are both available and it is easy to select the correct function through the clearly-labelled dial.

Accessories include test leads, test probes, batteries and a carry case and the Chauvin Arnoux F65 benefits from a Cat III 300V safety rating.

Chauvin Arnoux part number: P01120761

Key Features

  • True RMS measurement for AC values
  • Anti-harmonic filter
  • 70dB immunity from current eddies
  • 28mm clamp jaw
  • AC current range: 0 to 100A
  • 10µA resolution
  • Voltage measurement: 600V
  • Resistance measurement: 1kΩ
  • Frequency measurement: 1kHz
  • Cat III 300V

What's In The Box?

  • Chauvin Arnoux F65 Earth Leakage Clamp
  • 1 x set of elbowed male banana/straight male banana leads,
  • 1 x set of test probes, 
  • 2 x 1.5 V AAA/LR3 batteries 
  • 1 x bag
  • 1 x operating manual in 5 languages
Specification

AC Current

  • Range: 60mA to 100A
  • Resolution: 10µA to 10mA
  • Accuracy: 1.2% ±5 counts

AC Voltage

  • Range: 0 to 600V
  • Resolution: 0.1V
  • Accuracy: 1% ± 5 counts

DC Voltage

  • Range: 0 to 600V
  • Resolution: 0.1V
  • Accuracy: 1% ± 2 counts

Resistance

  • Range: 0 to 1kΩ
  • Resolution: 0.1Ω
  • Accuracy: 1% ± 3 counts

Frequency

  • Range: 1kHz
  • Resolution: 0.1Hz
  • Accuracy: 0.5% ± 2

General

  • Display: 10,000 counts - 2 measurements / s
  • Backlit LCD: Yes
  • MAX. value: 100 ms
  • Relative measurement (∆0): Yes
  • Automatic switch-off/ HOLD function: Yes
  • Large clamping diameter: 28 mm
  • Dimensions: 218 x 64 x 30 mm
  • Weight: 280 g (with batteries)
  • Standards: IEC 61010-1 / IEC 61010-2-032 / IEC 61010-2-033
  • Installation category: CAT III 300 V
  • Protection rating of casing: IP 30 as per NF EN 60529
Label Type Size Download
pdf Chauvin Arnoux F6X Datasheet pdf 901.7 KB Download