Chauvin Arnoux Health and Safety Environmental Tester Kit

SKU: CHAUHSKIT
  • A complete set for measuring the working environment
  • Measure air flow speed, humidity and air temperature
  • Measure noise levels, electromagnetic fields, and light levels
More Info
Typically ships in 5-7 working days

Chauvin Arnoux Health and Safety Environmental Tester Kit

The Chauvin Arnoux Health and Safety Environmental Tester Kit is a complete solution for those looking to create and monitor a safe, comfortable working environment for employees. The kit contains a range of environmental testers that will allow compliance with relevant legislation as well as quantified measurements of environmental conditions.

Chauvin Arnoux CA1110 Light Meter

The Chauvin Arnoux CA1110 Light Meter is capable of measuring light levels from 0.1Lux to 200,000Lux from light sources including LEDs, fluorescent tubes and regular incandescent bulbs. Additionally there is a mapping function that can calculate the illuminance around a room and an internal memory for up to one million data points. Other functions include CIE spectral correction and incidence correction whilst a detachable light sensor allows the user to take measurements at specific points.

Chauvin Arnoux CA1227 Thermo-Anemometer

The Chauvin Arnoux CA1227 Thermo-Anemometer is capable of measuring air flow velocity via its 8mm vane anemometer. It has velocity measurement range of 0.5m/s to 27m/s with accuracy of ±3% ± 0.1m/s and a precision of 0.01m/s. Additionally, there is an air temperature measurement range of -20˚C to 50˚C with accuracy of ±0.8˚C and a resolution of 0.1˚C. Other features include min/max/avg recording, an internal memory, and data logger transport software with automatic report generations.

Chauvin Arnoux CA1246 Thermohygrometer

The Chauvin Arnoux CA1246 Thermohygrometer measures relative humidity from 3% to 98% and air temperature from -10˚C to 60˚C. This allows the instrument to calculate dew point and it has min/max recording as well as a display hold function. A large internal memory has space for up to one million readings and it is capable of connecting to computers and software over a USB lead or a Bluetooth connection.

Chauvin Arnoux CA832 Sound Level Meter

The Chauvin Arnoux CA832 Sound Level Meter has measurement range of 35dB to 130dB over three dynamic ranges and readings are accurate to 1.5dB and precise to 0.1dB. It is particularly useful in terms of health & safety because of two different frequency curves, one of which places particularly emphasis on the sounds most prominent for the human hearing range. With loud noises the principal cause of occupational disease claims (75% of all claims), this sonometer is the easiest and most accurate way of establishing what employees are exposed to.

Chauvin Arnoux VX0100 EMF Meter

Electromagnetic field exposure has been linked with a variety of health issues, particularly in ‘at risk’ industries such as healthcare, power distribution and electricity generation. The Chauvin Arnoux VX0100 EMF Meter is capable of measuring electromagnetic fields, thus allowing the user to measure exposure and therefore meet the Control of Electromagnetic Fields at Work Regulations 2016.

Kit Contents

  • Chauvin Arnoux CA1110 Light Meter
  • Chauvin Arnoux CA1227 Thermo-Anemometer
  • Chauvin Arnoux CA1246 Thermohygrometer
  • Chauvin Arnoux CA832 Sound Level Meter
  • Chauvin Arnoux VX0100 EMF Meter

What's In The Box?

  • Chauvin Arnoux CA1110 Light Meter
  • Chauvin Arnoux CA1227 Thermo-Anemometer
  • Chauvin Arnoux CA1246 Thermohygrometer
  • Chauvin Arnoux CA832 Sound Level Meter
  • Chauvin Arnoux VX0100 EMF Meter
Specification

Chauvin Arnoux CA1110 Light Meter

Measurement

  • Measurement range: 0.1Lux to 200,000Lux / 0.01fc to 18580fc
  • Resolution: 0.1 lx (0.1 lx to 999.9 lx); 1 lx (1 000 lx to 9,999 lx); 10 lx (10,000 lx to 99.99 klx); 100 lx beyond / 0.01 fc (0.01 fc to 99.99 fc) 0.1 fc (100.0 fc to 999.9 fc) 1 fc (1,000 to 9.999 fc) 10 fc beyond 
  • Intrinsic uncertainty (Class C luxmeter as per the NF C 42-710 standard): ± 3% of reading on incandescent sources (by default); ± 6% of reading on LEDs (3,000 K to 6,000 K); ± 9% of reading on fluorescent sources
  • Intrinsic uncertainty (with compensation): LED mode - ± 4% of reading (at 4,000 K); Fluorescent mode - ± 4% of reading (type F11, 4,000 K)

Functions

  • Recording: Manual start/stop on the product, short press for MEM - spot recording; Long press for REC: recording at the rate of the current mode; programmed recording - Start date, recording interval (from 1 minute to 2 hours) and end date are defined using the PC software
  • Data storage: >1 million points
  • Min-Avg-Max-Hold: Yes
  • MAP mode: The MAP function can be used to map the lighting on a surface or in a room. In this way, the lighting measurements are saved in the same le.
  • Units: Lux or fc
  • Backlighting: Yes
  • Automatic power-off: Yes

Power Supply

  • Type: 3 x 1.5 V AA / LR6 alkaline batteries. Connection to the mains possible with the mains / micro-USB adapter offered as an accessory.
  • Battery life: 500 hrs (portable mode) / 3 years of recording (15-minute measurement interval)

Physical Specifications

  • Interfaces: Bluetooth / USB
  • Mounting: Casing equipped with a magnet, a wall-mount system and a slot for suspending the product. Compatible with the Multi x accessory.
  • Dimensions: 150 x 72 x 32mm (casing) / 67 x 64 x 35mm (sensor)
  • Weight: 345g
  • Ingress protection: IP50
  • Product operating ranges: -10˚C to 60˚C / 0 to 90%
  • Compliance: IEC61010-1 / IEC 61326-1 / Class C luxmeter as per the French NF C 42-710 standard based on the CIE guidelines

General

  • Data Logger Transfer Windows PC software functions: Display as a graph or a table of values / Data export in graph or Excel table form
Real-time mode / Automatic report generation in Word format / Data format compatible with the Dataview software offered as an accessory 
  • Warranty: 2 years

Chauvin Arnoux CA1227 Thermo-Anemometer

Air flow velocity

  • Range: 0.25m/s to 35m/s
  • Resolution: 0.01m/s (0.25m/s to 2.99m/s); 0.1m/s (≥3m/s)
  • Accuracy: ±3% ±4 counts

Volume flow

  • Range: 0 to 2999m3/h
  • Resolution: 0.01 m3/h ( 0.00 to 2.99 m3/h); 0.1 m3/h ( 3.0 to 99.9 m3/h); 1 m3/h (100 to 2,999 m3/h)
  • Accuracy: ±8%

Temperature

  • Sensor type: CTN
  • Range: -20˚C to 50˚C
  • Resolution: 0.1˚C
  • Accuracy: ±0.8˚C (0 to 50˚C)

Functions

  • Recording: Manual Start / Stop on the product: short press for MEM spot recording / Long press for REC recording at the rate of the current mode; Programmed recording: start date, recording interval (1 minute to 2 hours) and end date defined using the PC software
  • Data storage: >1,000,000 values
  • Min/Max/Average/Data Hold: Yes
  • MAP Mode: The MAP function can be used to map the air speeds measured
Flow-rate measurement: Yes, direct reading with the cones proposed as accessories or on the basis of a surface de ned by the user. 
  • Backlighting: Yes
  • Units: Air-speed units: m/s, km/h, fpm, mph; Air flow-rate units: m3/s, m3/h, l/s, cfm; temperature: ˚C, ˚F
  • Automatic power off: Yes

Power Supply

  • Type: 3 x AA 1.5V batteries; Mains connection possible with the mains / micro-USB adapter offered as an accessory.
  • Battery life: 200 hrs (portable mode) / 8 days of recording (15-minute intervals)

Physical Specifications

  • Interfaces: Bluetooth; USB
  • Mounting: Casing equipped with a magnet, a wall-mount system and a slot for suspending the product. Compatible with the Multi x accessory.
  • Dimensions: 17 x 72 x 32mm
  • Weight: 260g
  • Ingress protection: IP54
  • Product operating range: -10˚C to 60˚C; 10 to 90% RH
  • Compliance: IEC61010-1 / IEC 61326-1

General Specifications

  • Data Logger Transfer Windows PC software functions: Display as a graph or a table of values / Data export in graph or Excel table form. Real-time mode / Automatic report generation in Word format / Data format compatible with the Dataview software offered as an accessory.
  • Warranty: 2 years

Chauvin Arnoux CA1246 Thermohygrometer

Humidity

  • Type: Capacitive sensor
  • Measurement range: 3 to 98%
  • Resolution: 0.1% RH
  • Accuracy: 10 to 90 %RH: ± (2 %RH ± 1 ct), outside that range: ± (4 %RH ± 1 ct) 
  • Response time: 60s

Temperature

  • Type of sensor: Semiconductor
  • Measurement range: -10˚C to 60˚C
  • Resolution: 0.1˚C
  • Accuracy: 10 to 40°C: ± (0.5°C ± 1 ct); outside that range: ± (0.032 x (T-25) ± 1 ct) / T= temperature in °C 
  • Response time: 30s

Dew Point

  • Measurement range: -20˚C to 60˚C
  • Resolution: 0.1˚C

Functions

  • Recording: Manual Start / Stop on the product short press for MEM spot recording / Long press for REC recording at the rate of the current mode Programmed recording: start date, recording interval (1 minute to 2 hours) and end date de ned using the PC software
  • Alarms: Alarm thresholds settable in the software / Recording can be triggered on an alarm threshold
  • Data storage: >1 million points
  • Min-Max-Hold: Yes
  • Units: ˚C or ˚F / RH
  • Backlighting: Yes
  • Auto power off: Yes (configurable)

Power supply

  • Type: 3 x 1.5V AA / LR6 alkaline batteries; connection to the mains possible with the mains / micro-USB adapter offered as an accessory
  • Battery life: 1,000 hrs (portable mode) / 3 years of recording (15-minute measurement interval)

Physical Specification

  • Interfaces: 2 possible communication modes: Bluetooth wireless link and USB 
  • Mounting: Casing equipped with a magnet, a wall-mount system and a slot for suspending the product Compatible with the Multi x accessory.
  • Dimensions / Weight: 187 x 72 x 32 mm / 260 g with batteries
Ingress protection: IP54
  • Product operating ranges: -10˚C to 60˚C / 10 to 90% RH
  • Compliance: IEC61010-1 / IEC 61326-1

General

  • Data Logger Transfer Windows PC software functions: Display as a graph or a table of values / Data export in graph or Excel table form; Real-time mode / Automatic report generation in Word format / Data format compatible with the Dataview software offered as an accessory

  • Warranty: 2 years

Chauvin Arnoux CA832 Sound Level Meter

  • Measurement range: 3 measurement ranges; 37 dB to 130 dB 
  • Accuracy: ±1.5 dB 
  • Resolution: 0.1 dB 
  • Integration time: Slow (550 ms); Fast (55 ms) 
  • Weighting curves: dB(A) and dB(C) 
  • Analogue output: 10 mV/dB and 1 Vrms on 600 Ω

Operating conditions

  • Temperature: 0 to 50 °C 
  • Humidity: < 80 % RH

Storing conditions

  • Temperature: -20 °C to +60 °C 
  • Humidity: < 80 % RH 
  • Dimensions: 205 x 60.5 x 38 mm 
  • Mass: 230 g

Chauvin Arnoux VX0100 EMF Meter

Measurement Sensitivity & Accuracy

  • 2 sensitivity ranges (compatible with standards): 1.0 to 200.0V/m, 100 to 2,000V/m
  • Accuracy (in “laboratory” conditions): ±3% ±5 D at 50/60Hz

Measurement Frequency Range

  • Analysis of equipment connected to the mains: 5Hz to 3kHz (3kHz low-pass filter), 3kHz to 100kHz (2kHz high-pass filter), 5Hz to 100kHz (3kHz without filter)
  • Power: 9V battery (included): Battery life 60 - 80 hours
  • Safety: Reversed (M/F) antenna and earth terminals
  • Protection: Protected reference contact
  • IP65 protection
  • Dimensions: 63.6 x 163 x 40 mm
  • Weight: approx. 200g with battery
  • Warranty: 2 years