Specification
- IR Resolution - 160 x 120 (19,200 pixels)
- Display Counts - 6000
- AC/DC Voltage - 1000V AC RMS ±(1.0% + 3) 1000V DC ±(0.09% +3)
- AC/DC Amps - 10.00A AC RMS ±(1.5%+3) 10.00A DC ±(1.0%+3)
- Connectivity - Bluetooth BLE
Imaging & Optical
- Colour Palettes - Iron, rainbow, arctic, white hot, and black hot
- Field of View (Visual) - 71° x 56°
- Focus - Fixed
- Frame Rate - 9Hz
- Image Modes -
Thermal MSX (Multi Spectral Dynamic Imaging) Thermal Camera only Digital Camera only
- IR Resolution - 160 x 120 (19,200 pixels)
- IR Sensitivity - 150mK (0.15°C)
- Spectral Response - 8–14µm
- Thermal Imaging Detector - FLIR Lepton microbolometer
- Visual Focus and FOV - Fixed focus, 71° x 56° FOV
- Visual Resolution - 2MP (1600 X 1200 pixels)
Measurement & Analysis
- AC/DC Amps - 10.00A AC RMS ±(1.5%+3) 10.00A DC ±(1.0%+3)
- AC/DC LoZ V - 1000V AC RMS or 1000V DC ±(1.3%+4)
- AC/DC mVolt - AC 600.0mV ±(1.0%+3) DC 600.0 mV ±(0.2%+3)
- AC/DC Voltage - 1000V AC RMS ±(1.0%+3) 1000V DC ±(0.09%+3)
- Calibration Cycle - Once per year, recommended
- Capacitance - 10.00mF ±(4.0%+5)
- Continuity Check Threshold - 10-100Ω
- Diode Test - 1,500V ±0.9%
- Display Counts - 6000
- Frequency Counter - 100.00kHz ±(0.1%+5)
- Measuring Rate - 3 samples per second
- Resistance - 6.000 MΩ ±(0.9%+5), 60.00MΩ ±(3.0%+5)
- Temperature Accuracy - ±3°C (5.4°F) or ±3% of the reading (whichever is greater) for temperatures > 25°C (77°F) ±5°C for temperatures -10°C to 25°C (14°F to 77°F)
- Temperature Range - -5°C to 300°C (23°F to 572°F)
- Temperature Resolution - 0.1°C (0.1°F)
- Temperature Type K Thermocouple - -40°C to 400°C DMM ±(1.0% + 3°C)/ IGM ±(1.0% + 5°C)(-40°F to 752°F DMM ±(1.0% + 5.4°F) / IGM ±(1.0% + 9°F)
- Thermal Sensitivity - 150mK (0.15°C)
- VFD - AC V: 1000V AC RMS, ±(1.3%+4) at 45∽65 Hz
Communication & Data Storage
- Connectivity - Bluetooth BLE
- Image File Format - Radiometric
- Storage - 40,000 readings per memory set
- Storage Media - eMMC 4GB
- Stored Image Capacity - up to 30,000
- Video Recording - 50 minutes maximum duration, 20 seconds maximum duration for file transmission
User Interface
- Display - 2.8"
- Display Brightness - High, Medium, Low
Power
- Auto Power Off -
For Meter: set to OFF, 2, 5, or 10 minutes For Worklight only: set to OFF, 5, 15, or 30 minutes
- Battery - TA04, Lithium Polymer Rechargeable, 3050mAh, Two supplied
- Battery Life - Approximately 6.5 hours in IGM mode with display brightness set to medium, Approximately 10 hours in Multimeter mode (medium brightness)
- Non-Contact Voltage Detector - Yes
General
- Dimensions (L x W x H) - 20cm x 9.6cm x 5.6cm (7.9in x 3.8in x 2.2in)
- Scanning Mode - Continuous scan, Crosshairs and laser pointer targeting
- Weight - 569g (1.25lb) without battery (approximately)
- Worklights - x1 LED
Environmental & Certifications
- Certifications - ETL, FCC, CE, RCM, UKCA, FDA, EN60825, EN50689
- Drop Test - 2m (6.6ft)
- EMC - EN61326-1
- Emissivity Settings - 0.10 to 1.00 (default is 0.95); select from four presets or set manually
- IP Rating - IP40
- Laser Pointer Power - ≤0.39mW
- Laser Type - Class I (red)
- Laser Wavelength - 640nm to 660nm
- Operating Altitude - 2000m (6560ft)
- Operating Temperature & Humidity -
-10°C to 30°C (14°F TO 86°F), <85% RH -30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH
- Pollution Degree - 2.0
- Safety - IEC 61010-1 CAT IV - 600V, CAT III - 1000V
- Storage Temperature and Relative Humidity (RH) - -20°C to 60°C (-4°F to 140°F), 0-80% RH (without batteries)
- Warranty - Limited 10-Year Warranty
- Software - FLIR METERLiNK app
|