FLIR EV45-T2
Measurement & Analysis
- CP Error (E state) Simulation – Pass/Fault (CP signal short-circuited to PE)
- CP State Simulation – A (Disconnected), B (Connected), C (Charging), D (Charging w/ ventilation), E (Error)
- Input Type – Measuring Terminals: L1, L2, L3, N, PE Output for test purposes only: Max. 250 V
Single Phase / 430 V (3 phase), 50 / 60 Hz, CAT II 300 V, Max. 10 A
- PE Error Simulation – Pass/Fault (Interruption of PE conductor)
- PE Pre-Test – Pass/Fault (>50 V AC/DC between PE conductor and touch sensor)
- PP State Simulation – Open, 13 A, 20 A, 32 A, 63 A
- RCD/CCID Trip Test – Pass/Fault (Test RCD/CCID activation once tripped)
- Voltage Phase Indication – L1, L2, L3
Communication & Data Storage
- Connector Types – T2 (Built-in), Type 1 (converter included)
Power
- Battery Life – Approx. 100 hours, with alkaline batteries
- Battery Type – 4 x AA Alkaline batteries
General
- Size (L x W x H) – 237 mm x 65 mm x 56 mm (9.33 in x 2.56 in x 2.20 in)
Environmental & Certifications
- Certifications – ETL, CE, RCM
- EMC – EN61326-1
- Operating Altitude – 2000 m (6560 ft)
- Operating Ambient Temperature and Relative Humidity (RH) -
−10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH
- Safety Category – CAT II-300 V, IEC 61010-1
- Storage temperature and relative humidity (RH) - −20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries)
- Warranty – Limited 3-Year Warranty
FLIR DM286
Imaging & Optical
- Colour Palettes – Iron, rainbow, arctic, white hot, and black hot
- Field of view – visual – 71° x 56°
- Focus – Fixed
- Frame Rate – 9 Hz
- Image Modes -
Thermal MSX (Multi Spectral Dynamic Imaging) Thermal Camera only Digital Camera only
- IR Resolution – 160 x 120 (19,200 pixels)
- IR Sensitivity – 150 mK (0.15°C)
- Spectral Response – 8-14 µm
- Thermal Imaging Detector – FLIR Lepton microbolometer
- Visual Focus and FOV – Fixed focus, 71° x 56° FOV
- Visual Resolution – 2 MP (1600 x 1200 pixels)
Measurement & Analysis
- AC/DC Amps – 10.00 A AC RMS ± (1.5%+3) 10.00 A DC ± (1.0%+3)
- AC/DC LoZ V – 1000 V AC RMS or 1000 V DC ± (1.3%+4)
- AC/DC mVolt – AC 600.0 mV ±(1.0% + 3) DC 600.0 mV ±(0.2%+3)
- AC/DC Voltage – 1000 V AC RMS ±(1.0% + 3) 1000 V DC ±(0.09%+3)
- Calibration Cycle – Once per year, recommended
- Capacitance – 10.00 mF ±(4.0%+5)
- Continuity check threshold – 10-100Ω
- Diode Test – 1.500 V ± 0.9%
- Display Counts – 6000
- Frequency Counter – 100.00 kHz ±(0.1%+5)
- Measuring Rate – 3 samples per second
- Resistance - 6.000 MΩ ±(0.9%+5), 60.00 MΩ ±(3.0%+5)
- Temperature Accuracy - ±3°C (5.4°F) or ± 3% of the reading (whichever is greater) for temperatures > 25°C (77°F) ±5°C for temperatures -10°C to 25°C (14°F to 77°F)
- Temperature Range - -5°C to 300°C (23°F to 57.2°F)
- Temperature Resolution – 0.1°C (0.1°F)
- Temperature Type K thermocouple - -40°C to 400°C DMM ± (1.0% + 3°C) / IGM ± (1.0% + 5°C)
(-40°F to 752°F DMM ± (1.0% + 5.4°F) / IGM ± (1.0% + 9°F)
- Thermal Sensitivity – 150 mK (0.15°C)
- VFD – AC V 1000 V AC RMS, ±(1.3%+4) at 45-65 Hz
Communcation & Data Storage
- Communication Protocol – METERLiNK
- Connectivity – Bluetooth BLE
- Image File Format – Radiometric
- Storage – 40,000 readings per memory set
- Storage Media – eMMC 4GB
- Stored Image Capacity – up to 30,000
- Video Recording – 50 minutes maximum duration, 20 seconds max duration for file transmission
User Interface
- Display – 2.8”
- Display Brightness – High, Medium, Low
Power
- Auto Power Off -
For Meter: set to OFF, 2.5, or 10 minutes For Worklight only: set to OFF, 5, 15, or 30 minutes
- Battery – TA04, Lithium Polymer Rechargeable, 3050 mAh. Two supplied
- Battery Life -
Approx. 6.5 hours in IGM mode with display brightness set to medium Approx. 10 hours in Multimeter mode (medium brightness)
- Non_Contact Voltage Detector (NCV) – Yes
General
- Dimensions (L x W x H) – 20 cm x 9.6 cm x 5.6 cm (7.9 in x 3.8 in x 2.2 in)
- Scanning Mode – Continuous scan. Crosshairs and laser point targeting
- Weight – 569 g (1.25 lb) without battery (approx..)
- Worklights – x1 LED
Environmental & Certifications
- Certifications – ETL, FCC, CE, RCM, UKCA, FDA, EN60825, EN50689
- Drop Test – 2 m (6.6 ft)
- EMC – EN61326-1
- Emissivity Settings – 0.10 to 1.00 (default is 0.95); select from four presets or set manually
- IP Rating – IP40
- Laser Pointer Power - ≤0.39 mW
- Laser Type – Class I (red)
- Laser Wavelength – 640 nm to 660 nm
- Operating Altitude – 2000 m (6560 ft)
- Operating Temp & Humidity -
-10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH
- Pollution Degree – 2.0
- Safety – IEC 61010-1 CAT IV – 600 V, CAT III – 1000 V
- Storage temperature and relative humidity (RH) - -20°C to 60°C (-4°F to 140°F), 0–80% RH (without batteries)
- Warranty – Limited 10-Year Warranty
|