Fluke 190-102-III ScopeMeter Portable Oscilloscope 100MHz

SKU: FLUKE190102-CONF
  • With a 5.0GS/s sampling rate and a 200ps resolution, this tool is perfect for critical troubleshooting issues
  • The Fluke 190-102-III ScopeMeter has been masterfully designed for use in industrial electronic process controls
  • Choose between the standard version of the product, or opt for a kit including a carry case, WiFi USB and FlukeView software
More Info

Fluke 190-102-III ScopeMeter Portable Oscilloscope 100MHz

The Fluke 190-062 ScopeMeter has been expertly designed to offer the high performance expected of an oscilloscope, with the highest safety ratings and the ability to be used in even the most difficult industrial conditions. The testing tool is suitable for a wide range of troubleshooting tasks, with a 5.0GS/s and a 200ps resolution meaning that noise and other potential issues can be captured with ease. An IP51 rating means that the tool is protected from water droplets, dust, humidity, and fluctuating temperatures, which emphasises its versatility across a range of job sites. This tool is an ideal choice for industry professionals.

The 190-062 has been designed for use in the industrial electronics sector, where it can be used to troubleshoot on Transducers/Sensors, Loop Controllers, and Calibrated Gauges. The bandwidth of 100MHz, when combined with two scope modes and the ability to run power measurements, ensures that you can be confident that this instrument will suit whatever you need it for. When in 'Scope' mode, the 190-102 is able to store up to 10,000 samples per channel, meaning that the user can capture accurate and detailed waveforms, which can then be compared and contrasted in order to consolidate your findings.

The Oscilloscope is also equipped with these exciting features:

  • Connect-and-View - this feature automatically establishes accurate triggering by identifying signal patterns. Users don't even need to press a button, yet they can observe a stable, dependable, and consistent display of nearly any signal.
  • TrendPlot - this functions as a paperless recorder capable of storing data for up to 22 days, enabling users to identify intermittent faults. These faults are often challenging to pinpoint, but the ScopeMeter can effectively locate and diagnose such issues.
  • ScopeRecord - the ScopeRecord memory can store up to 30,000 or more data points per channel, effectively capturing intermittents and glitches as short as 8 nanoseconds.

Fluke Connect-and-View

If the wrong settings are used on an oscilloscope, the wrong measurement data will be displayed which can severely impact the accuracy of results. Connect-and-View can recognise signal patterns, set up the correct triggering, and provide a stable and accurate display. The user can sit back as Connect-and-View automatically recognises signal changes.

Optional FlukeView

FlukeView can expand the power of Fluke's testing tools, by addressing the demands for reporting and documentation through documenting, storing, and the analysis of readings or measurements.

By selecting the kit option from the drop-down menu above, you will receive a code for the full version of FlukeView, which allows a user to edit an existing form or create a new form to customize the report to individual needs.

The 190-102-III Kit Option

The 190-102-III is supplied with a wide range of accessories, such as a Battery Charger/Mains Adaptor, BP290 Battery, and various test leads and clips that are listed in full below in the 'What's in the Box?' section. However, if you opt for the kit option, you will receive all of these accessories, plus a carry case, a code for FlukeView Software, and a Wi-Fi dongle.

Fluke Selection Guide - Decide What Is Best for You

Features 123 124 125 190-062 190-102 190-202 190-104 190-204 190-504
Bandwidth (MHz) 20 40 40 60 100 200 100 200 500
Scope Inputs 2 2 2 2 2 2 4 4 4
Dedicated DDM 2 2 2 1 1 1 - - -
Dual Input Trendplot - - -
Four Input Trendplot - - - - - -
ScopeRecord Mode - - -
Automatic Capture & Replay Mode - - -
Cursors -
Zoom - - -
Bus Health Test Mode - - - - - - - -
Advanced Power Measurements    
EN61010-1 CAT III Safety Rating 600V 600V 600V 1000V 1000V 1000V 1000V 1000V 1000V
EN61010-1 CAT IV Safety Rating - - - 600V 600V 600V 600V 600V 600V
Battery 7 hr NiMH 7 hr NiMH 7 hr NiMH 4 hr Li0Ion (8 hr Opt) 4 hr Li0Ion (8 hr Opt) 7 hr Li-Ion 7 hr Li-Ion 7 hr Li-Ion 7 hr Li-Ion
Optical RS-232 - - - - - -
Isolated USB Opt Opt Opt
Isolated USB Memory - - -

Fluke part number: 5282331/5282354

Key Features

  • CAT III 1000V/CAT IV 600V safety rated
  • 60MHz bandwidth
  • 5.0GS/s
  • 10,000 samples per channel waveform
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View for automatic triggering
  • ScopeRecord mode that captures waveform sample data
  • TrendPlot offers trend measurement readings up to 22 days
  • Advanced automatic measurements of power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP51 rating
  • Li-Ion battery for extended operating time

What's In The Box?

Both the FLUKE-190-062-III and FLUKE-190-062-III-S are supplied with:

  • Fluke 190-062-III ScopeMeter
  • Battery Charger/Mains Adaptor
  • BP290 Battery
  • 2 x VPS421-x Probes with 4mm Banana Tips
  • 2 x Large Jaw Crocodile Clips (1 red, 1 blue)
  • 2 x TL175 Test Leads with Test Pins (1 red, 1 blue)
  • Hangstrap
  • Handstrap
  • Download Information for User Manual
  • Download Information for FlukeView-2 Demo Package
  • USB Interface Cable

The following things are only supplied should you opt for the S kit:

  • All of the above, plus:
  • CXT293 Protective Carry Case
  • Activation Code for FlukeView Software
  • Wi-Fi Dongle
Specification
Input Voltage Range
  • Rated maximum floating voltage - CAT III 1000V/CAT IV 600V (maximum voltage between any contact and earth-ground voltage level)
  • Probe input voltage VPS410-II - CAT III 1000V/CAT IV 600V (maximum voltage between standard 10:1 probe tip and reference lead)
  • Probe input voltage VPS421 - CAT III 1000V/CAT IV 600V (maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
  • Maximum BNC input voltage - CAT IV 300V (maximum voltage on BNC input directly)
  • Maximum voltage on meter input - CAT III 1000V/CAT IV 600V (safety designed banana input connectors)
Memory Save and Recall
  • Memory locations (internal) - 30 waveform memories plus 10 recording memories plus 9 screen copy memories
  • 30 waveform memories - Each memory can contain up to 2 or 4 waveforms plus corresponding setups
  • 10 recording memories - Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements
  • External data storage - On PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port
  • Screencopies - On PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
  • Volatility - Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status
  • Real-time clock - Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings
Case
  • Design - Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard. Kensington lock supported to lock down instrument when left unattended
  • Drip and dust proof - IP51 according to IEC60529
  • Shock and vibration - Shock 30g, vibration (sinusoidal) 3g/ 0.03g2/Hz (Random), according to MIL-PRF-28800F Class 2
  • Display size - 133mm x 90mm (5.3in x 3.5in) LCD
  • Resolution - 1120 pixels x 765 pixels
  • Brightness - User-adjustable, up to 300 cd/m2
Mechanical Data
  • Size - 265mm x 192mm x 70mm (10.5in x 7.6in x 2.8in)
  • Weight (including battery) - 2.1kg (4.6lb)
Power
  • Line Power - Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100Vac to 240Vac, ±10 %, 50-60Hz
  • Battery Power - Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
  • Battery type (incl.) and capacity (+opt. battery) - BP290: 10.8V, 2500mAh
  • Battery charge indicator - Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen
  • Battery operating time (with backlight low) - Up to 3.5 using BP290 (included), up to 7 hours using BP291 (optional)
  • Battery charging time - 2 1/2 hours using BP290; 5 hours using BP291
  • Battery power saving functions - Auto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time. On-screen battery power indicator
Safety
  • EN61010-1, Pollution Degree 2; IEC61010-2-030: CAT IV 600V/CAT III 1000V
Environmental
  • Operating temperature - Battery discharging: 0°C to 40°C (32°F to 104°F), Battery charging: 0°C to 40°C (32°F to 104°F)
  • Storage temperature - -20°C to 60°C (-4°F to 140°F)
  • Humidity - 0°C to 10°C (32°F to 50°F): noncondensing, 10°C to 30°C (50°F to 86°F): 95% (±5%), 30°C to 40°C (86°F to 104°F): 75% (±5%), 40°C to 50°C (104°F to 122°F): 45% (±5%)
  • Maximum operating altitude - CAT IV 600V, CAT III 1000V: up to 2000m (6,600feet), CAT IV 300V, CAT III 600V, CAT II 1000V: up to 4000m (13,000 feet)
  • Maximum storage altitude - 12km (40,000ft)
  • Electro-Magnetic Compatibility - IEC 61326-1: Industrial; CISPR 11: Group 1, Class A; Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment): USA (FCC): 47 CFR 15 subpart C
  • Interfaces - Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry. USB-host port directly connects to external flash memory drive (up to 32GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFi. Adaptor for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2.
  • Probe calibration output - Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel. Generator Output: 1.225Vpp/500Hz square wave
  • Warranty - 3 years on main instrument, 1 year on battery and accessories