Fluke 2062 Advanced PRO Wire Tracer and Cable Locator Kit

SKU: FLUKE2062
  • Flukes Patented Smart Sensor™ locates and displays energised wires on a colour display
  • Locate energised and de-energised wires quickly and accurately in walls, ceilings, and floors
  • Kit includes Fluke 2000T Transmitter, i400 AC Current Clamp and 2000ACC Test Lead Accessory Kit
More Info
Typically ships in 7-10 working days

"Buy a Fluke, get a FREE Fluke" promotion. Spend £150 or more on any qualified Fluke product(s) and claim a FREE Fluke gift!
[Click here to learn more] Offer is valid from 1st March to 31st August 2024.

Fluke 2062 Advanced PRO Wire Tracer and Cable Locator Kit

The Fluke 2062 Advanced PRO Wire Tracer and Cable Locator Kit allows for the location of both energised and de-energised wires quickly in walls, ceilings and floors and is CAT IV 600V safety rated. The Fluke 2062R offers protection to the user from dangerous levels of transient over voltage spikes up to 8000V that can occur in industrial and utility environments.

Smart Sensor™

Using Flukes patented Smart Sensor™, users are able to locate and display energised wires within walls, floors and ceilings on the 3.5 inch TFT colour LCD display. Embedded help screens on the display that make the unit easier to use. The tip sensor also provides an audible tone when wires are located and the smart sensor helps to pinpoint the orientation of energised wire, eliminating any guesswork.

The Fluke 2062R advanced Pro Wire Tracer and Cable locator Kit includes an accessory kit providing test leads, test probes, blade and round outlet adaptors, and alligator clips that connect the transmitter to electrical systems. Also included in the kit is the Fluke i400 current clamp that can be used with the loop mode that induces a boosted 6kHz signal through the insulation.

The Fluke 2062 has eight Receiver Sensitivity Levels offering more flexibility and accuracy when tracing wires. Powered by 4 x AA batteries users are able to use the Fluke 2062 for up to 20 hours with a battery indicator giving clear indication if battery power is low.

The Fluke 2062 can detect the signal in wires and cables using two methods: passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter form all other modes. Using the receivers tip sensor, operators of the Fluke 2062 can trace wires in corners, tight spaces and junction boxes. The Fluke 2062 has four receiver tracing modes:

  • Smart Sensor mode: Energised wire detection and visualisation displayed on the colour LCD screen
  • Tip Sensor Mode:: Provides a more accurate detection of a wire
  • Beaker Mode: Using Beaker Mode users can easily identify the breaker and fuse based on the highest recorded signal detected from the transmitter.
  • Non-Contract Voltage Detection Mode: using then in contact voltage detection mode energised wires can be traced with the use of the transmitter

Fluke 2052/2062 Advanced Wire Tracer Kit comparison table

  Fluke 2052 Fluke 2062
Measurement category: CAT IV 600V
Operating Voltage: 600V AC/DC
Operating frequency: Energised: 6.25 kHz/ De-Energised: 32.768 kHz
Response time:
Tip Sensor (Energised/De-Energised) 500ms
NCV 500ms
Battery Monitoring 5s
Smart sensor: 500ms
Tip Sensor (Energised/De-Energised) 500ms
NCV 500ms
Battery Monitoring 5s
Range detection (open air)
Tip Sensor: Energised: Max distance via air: Up to 6.1m (20ft)/Pinpointing approx: 5cm (1.97in)
Tip sensor: De-energised: Max distance via air: Up to 4.5m (14.7ft)/ Pinpointing: approx 5cm (1.97in)
NCV (40Hz to 400Hz): Max sensitivity: 90V up to 2m? Min sensitivity: 600V to to 1cm

Smart Sensor Direction Indication Mode ≤15 cm (6 in), 230 V AC, high mode, sensitivity level 2
Tip Sensor: Energised: Max distance via air: Up to 6.1m (20ft)/Pinpointing approx: 5cm (1.97in)
Tip sensor: De-energised: Max distance via air: Up to 4.5m (14.7ft)/ Pinpointing: approx 5cm (1.97in)
NCV (40Hz to 400Hz): Max sensitivity: 90V up to 2m? Min sensitivity: 600V to to 1cm
LCD Display Size 63mm (2.5in) 89mm (3.5in)
Display Resolution 240 x 320 480 x 320 pixels
Battery Life 16 hours 20 hours

Fluke 2000-T Transmitter

The Fluke 2000-T Transmitter works on both energised and de-energised circuits up to CAT IV 600V and provides users with three different modes: high, low and loop modes. Using thebmodesj, the strength of the induced signal which can provide more accurate results dependant on the circuit being traced.

  • High Mode is used for both normal energised and de-energised circuits
  • Low mode can be used for precision tracing with a low signal which reduces the coupling to nearby wires and metal objects.
  • Loop mode is used for closed loop de-energised circuits.

When using the 2000-T, the instrument will automatically sense whether the system is energised or de-energised and will select a 6kHz or 33kHz output frequency. With eight receiver sensitivity levels providing more flexibility and accuracy when tracing.

i400 AC Current Clamp

The included i400 AC current clamps allows for inducing a tracing signal Jon a cable when there is no access to a bare conductor.

Key Features

  • Kit includes Fluke 2062R Advanced Wire Tracer and Fluke 2000T Transmitter
  • Flukes patented Smart Sensor™, users are able to locate and display energised wires within walls, floors and ceiling
  • CAT IV 600V safety rated
  • Locate both energised and de-energised wires
  • The Fluke 2056R is protected against transient over voltage spikes up to to 8000V
  • Locate breaks, opens and shorts
  • Four modes: Smart Sensor mode, Tip Sensor mode, Beaker Mode, Non-Contract Voltage Detection Mode
  • Tip sensor provides an audible tone when wires are located
  • Smart sensor help to pinpoint the orientation of energised wire, eliminating any guesswork
  • Four modes: Smart Sensor mode, Tip Sensor mode, Beaker Mode, Non-Contract Voltage Detection Mode
  • Detect the signal in wires and cables using two methods: passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter form all other modes
  • Tip on the receiver allows for tracing of tight spaces, orders and junction boxes
  • Eight Receiver Sensitivity Levels offering more flexibility and accuracy when tracing wires
  • Battery powered by 4 x AA batteries
  • 3.5inch LCD colour TFT screen
  • IP 40 rated and 1m drop tested
  • Fluke 2000T Transmitter offers three signal strengths: High, Low, and Loop
  • The Fluke 2000-T transmitter will automatically sense whether the system is energised or de-energised and will select a 6kHz or 33kHz output frequency
  • Eight receiver sensitivity levels providing more flexibility and accuracy when tracing

What's In The Box?

  • Fluke 2062R Advanced Pro Wire Tracer Receiver with Smart Sensor™
  • Fluke 2000T Advanced Wire Tracer Transmitter
  • i400 AC Current Clamp
  • Fluke 2000ACC Test Lead Accessory kit for 2062
  • Smart strap magnetic hanger
  • Premium hard carrying case
  • Batteries
  • Quick reference guide
Specification

2062R Receiver

  • Measurement Category: CAT IV 600V
  • Operating Voltage: 600V AC/DC
  • Operating frequency:
    Energised: 6.25kHz
    De-energised: 32.768kHz
  • Signal indications: Numeric bar graph display and audible beep
  • Response time:
    Smart Sensor 500ms
    Tip sensor (energised/De-energised): 500ms
    NCV: 500ms
    Battery monitoring:5s
  • Range detection (open air):
    Smart Sensor Direction Indication Mode: ≤15 cm (6 in), 230 V AC, high mode, sensitivity level 2
    Tip Sensor: Energised: Max distance via air: Up to 6.1m (20ft)/Pinpointing approx: 5cm (1.97in)
    Tip sensor: De-energised: Max distance via air: Up to 4.5m (14.7ft)/ Pinpointing: approx 5cm (1.97in)
    NCV (40Hz to 400Hz): Max sensitivity: 90V up to 2m? Min sensitivity: 600V to to 1cm

Display

  • Display size: LCD 89mm (3.5in)
  • Display dimensions (W x H): 70mm x 52mm (2.76 x 2.07in)
  • Display Resolution: 480 x 320 pixels
  • Display Type: Colour TFT LCD
  • Display Colour: 16-bit
  • Backlight: Yes

Environmental

  • Operating temperature: -20ºC to 50ºC (-4ºF to 122ºF)
  • Operating humidity:
    45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F)
    95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F)
    75%: 30 °C to <40 °C (86 °F to <104 °F)
  • Operating altitude: 2000m (6581ft)
  • Pollution degree: 2
  • IP rating: IP40
  • Drop test: 1m (3.28ft)

Mechanical

  • Power supply: 4 x AA batteries
  • Power consumption (Typical): 110mA
  • Battery life: Approx 20 hours
  • Low battery indication: Yes
  • Dimensions (L x W x H): 277 x 112 x65mm (10.92 x 4.43 x 2.55in)
  • Weight: Approx 0.544KG (1.2lb)

2000T Transmitter

  • Measurement Category: CAT IV 600V
  • Operating Voltage: 600V AC/DC
  • Operating frequency:
    Energised: 6.25kHz
    De-energised: 32.768kHz
  • Signal indications: LEDs and audible beep
  • Response time:
    Line Voltage: 1s
    NCV: 500ms
    Battery monitoring:5s
  • Current output of signal (typical):
    Energised circuit: High mode: 60 mA rms/ Low mod: 30mA rms
    De-energised circuit: High mode: 110mA rms/Low mode: 40 mA rms/ Loop mode with test leads: 160mA rms/Loop mode with i400 AC current Clamp: 385mA rms
  • Signal voltage output (nominal):
    Energised circuit: High mode: 14W @ 230V ac/50 Hz, 3.33kΩ @ 230 V ac/ Low mode: 4.6 W @ 230 V ac/50 Hz, 11.5 kΩ @ 230 V ac
    De-energised circuit: High mode: 31 V RMS, 140 Vp-p, 0.86 W @ 1 kΩ load
    Low mode: 27.5 V RMS, 120 Vp-p, 0.1 W @ 1 kΩ load
    Loop mode with test leads: 32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load
    Loop mode with i400 AC Current Clamp: 31 mV, 0.89 W @ 1 Ω load
  • Range detection (open air):
    Tip Sensor: Energised: Max distance via air: Up to 6.1m (20ft)/Pinpointing approx: 5cm (1.97in)
    Tip sensor: De-energised: Max distance via air: Up to 4.5m (14.7ft)/ Pinpointing: approx 5cm (1.97in)
    NCV (40Hz to 400Hz): Max sensitivity: 90V up to 2m? Min sensitivity: 600V to to 1cm

Display

  • Display size: LEDs
  • Display Type: LEDs
  • Display Colour:
    Operating Mode LEDs: red
    Battery Status LEDs: green, yellow, red

Environmental

  • Operating temperature: -20ºC to 50ºC (-4ºF to 122ºF)
  • Operating humidity:
    45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F)
    95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F)
    75%: 30 °C to <40 °C (86 °F to <104 °F)
  • Operating altitude: 2000m (6581ft)
  • Pollution degree: 2
  • IP rating: IP40
  • Drop test: 1m (3.28ft)

Mechanical

  • Power supply: 8 x AA batteries
  • Power consumption (Typical):
    High/Low mode: 70mA
    Loop mode with clamp: 90mA
    Consumption without signal transmission: 10mA
  • Battery life:
    High/Low mode: approx 25hrs
    Loop mode: Approx 18hrs
  • Fuse: 1.6A, 700V fast acting, Ø 6 x 32 mm, 50 kA interrupt
  • Low battery indication: Yes
  • Dimensions (L x W x H): 183 x 93 x50mm (7.2 x 3.66 x 1.97in)
  • Weight: Approx 0.57KG (1.25lb)

i400AC Current Clamp

  • Measurement Category: CAT IV 600V/ CAT III 1000V
  • Operating Voltage: 1000V AC
  • Current Range: 400A
  • Basic accuracy: 2 % + 0.06 A (45 Hz to 400 Hz)

Environmental

  • Operating temperature: -20ºC to 50ºC (-4ºF to 122ºF)
  • Operating humidity:
    10 °C to <30 °C (95 %: 50 °F to <86 °F)
    30 °C to <40 °C (75 %: 86 °F to <104 °F)
    40 °C to <50 °C (45 %: 104 °F to <122 °F)
  • Operating altitude: 2000m (6581ft)
  • Pollution degree: 2
  • IP rating: IP40
  • Drop test: 1m (3.28ft)

Mechanical

  • Maximum conductor size: 32mm 91.26mm (1.26in)
  • Dimensions (L x W x H): 150 x 70 x30mm (5.9 x 2.75 x 1.18in)
  • Weight: Approx 0.114KG (0.25lb)

2000ACC Test Lead Accessory Kit

  • Includes:
    2 x 1m test leads (red,black)
    1 x 7m test lead (green)
    2 x test probes (black)
    2 x alligator clips (red, black)
    2 x outlet blade adaptors
    2 x outlet
  • Measurement category:
    CAT IV 600V (test leads), CAT II 1000V, CAT IV 600V (alligator clips)
    CAT II 300V (outlet adaptors)
  • Operatomg voltage and current:
    600V 10A max (red/black leads), 600V 10A max (green lead), 1000V 8A max (black probe)
    600V 10A max (alligator clips), 300V 10A max (outlet adaptors)
  • Operating temperature: 0°C to 50°C (32°F to 122°F)
  • Operating humidity:
    0°C to <30°C (95%: 50°F to <86°F), 30°C to <40°C (75%: 86°F to <104°F)
    40 °C to <50 °C (45 %: 104 °F to <122 °F)
  • Storage temperature and humidity: 0°C to 60°C (32°F to 140°F)
  • Operating altitude: 2000m (6561ft)
  • Pollution degree: 2
  • Water and dust resistance: IP20
  • Drop proof: 1m (3.28ft)
  • Dimensions: Red/black leads: 1m (3.28ft), Green lead: 7m (22.97ft), Alligator clips: approx. 95 x 45 x 24mm (3.74 x 1.77 x 0.94in), Outlet adapters: 72 x 18 x 18mm (2.83 x 0.71 x 0.71in)
  • Weight: Approx 0.4KG (0.88lb)
Label Type Size Download
pdf Fluke 2062 Advanced PRO Wire Tracer and Cable Locator Kit Datasheet pdf 294.2 KB Download