Fluke 566 Contact & Infrared Thermometer

SKU: FLUKE566

Never Beaten On Price

 

We’re always working hard to give you the best possible price, but if you find it cheaper somewhere else, we’ll endeavour to match the price.

 

Call 0113 248 9966 or contact us online

'Get Free Tools From FLUKE' Promotion
Typically ships in 5-7 working days
Need Some Help From Our Experts? chevron-right chevron-down

We're always happy to offer help, information & advice to find the right instrument for you, so please get in touch.

 

To speak to our sales team, call us on 0113 248 9966, use our Live Chat service or contact us online.

Members earn 489 reward points chevron-right chevron-down

Use reward points to get money off future purchases.

 

Please note: Customers must be signed into their account to be elegible. Find out more about reward points here.

FREE Delivery & 60 Day Returns chevron-right chevron-down

We offer FREE standard delivery on all orders over £249, with a range of next-day options also available on many items.

 

Find out more on our delivery information page.

Key Features
  • Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms with just a few touches of a button
  • The 566 has a rugged yet easy-to-use frame which can stand up to use in a wide range of challenging environments
  • A distance-to-spot ratio of 30:1 means that the user is able to measure smaller objects from a considerable distance

Related Categories

PROMOTION: Spend £100 (ex VAT) or more on any qualified Fluke products and claim FREE Tools From Fluke!
[Click here to learn more] Offer valid from 1st September to 31st December 2026.

Fluke 566 Contact & Infrared Thermometer

The Fluke 566 Contact & Infrared Thermometer makes the measurement of temperature a simple task, with a three-button, on-screen menu interface. The user is able to quickly navigate through the advanced features of the instrument, whether that be adjusting emissivity, or starting data logging. With a rugged, ergonomic design to ensure the thermometer is able to be used in tough environments, the user can feel safe that they have invested in a durable and accurate tool. Capture up to 20 points of data, which can be downloaded and recalled upon at a later time, with a distance-to-spot ratio of 30:1 ensuring that results can be gathered from further away./p>

The 566's features go way beyond what is usually associated with IR thermometers, which ensure that efficiency can be achieved in applications. With two levels of backlight on the display, an included Type-K Thermocouple bead probe, and audible and visual alarms that instantly alert the user to measurements that are outside of the set parameters, the 566 is a smart tool which can quickly identify problems.

Fluke part number: FLUKE566

Key Features

  • Adjustable emissivity that allows you to confidently measure a wide variety of surfaces
  • Up to 20 points of data for downloading and recalling later
  • Two levels of backlight on the display
  • Included K-Type thermocouple bead probe
  • Features audible and visual alarms to instantly alert you to measurements outside of your set limits
  • Provides MAX, MIN, DIF, and AG functions to quickly identify problems
  • Measure -40°C to 650°C/-40°F to 1202°F
  • Easy-to-access features thanks to the soft-key buttons
  • 30:1 distance-to-spot ratio

What's In The Box?

  • Fluke 566 Contact & Infrared Thermometer
  • K-Type Thermocouple Bead Probe
  • Hard Carry Case
  • Quick Start Guide
  • Users Manual
Show Trustpilot Reviews
Specification
No
  • Infrared Temperature Range - -40°C to 650°C (-40°F to 1202°F)
  • Infrared Accuracy - < 0°C (32°F): ± (1.0°C (± 2.0°F) + 0.1°/1°C or °F); > 0°C (32°F): ± 1 % or ± 1.0°C (± 2.0°F), whichever is greater
  • Display Resolution - 0.1°C / 0.1°F
  • Infrared Spectral Response - 8µm to 14µm
  • Infrared Response Time - <500 msec
  • Thermocouple Type-K Input Temperature Range - -270°C to 1372°C (-454°F to 2501°F)
  • Thermocouple Type-K Input Accuracy - -270°C to -40°C: ± (1°C + 0.2°/1°C) (-454°F to -40°F: ± (2°F + 0.2°/1°F)) -40°C to 1372°C: ± 1 % or 1°C (-40°F to 2501°F: ± 1 % or 2°F), whichever is greater
  • D:S (distance to measurement spot size) - 30:1
  • Laser Sighting - Single-point laser <1mw output Class 2 (III) operation, 630nm to 670nm
  • Minimum Spot Size - 19mm (0.75in)
  • Emissivity Adjustment - By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
  • Data Storage with Date/Time Stamp - 20 points
  • PC Interface and Cable - None
  • Hi/Low Alarms - Audible and two-colour visual
  • Min/Max/Avg/Dif - Yes
  • Display - Dot matrix 98 x 96 pixels with function menus
  • Backlight - Two levels, normal and extra bright for darker environments
  • Trigger Lock - Yes
  • Switchable Celsius and Fahrenheit - Yes
  • Power - 2 AA/LR6 Batteries
  • Battery Life - If used continuously: laser backlight on 12 hours; laser and backlight off, 100 hours
  • Operating Temperature - 0°C to 50°C (32°F to 122°F)
  • Storage Temperature - -20°C to 60°C (-40°F to 140°F)
  • Bead Thermocouple Type-K Range - -40°C to 260°C (-40°F to 500°F)
  • Bead Thermocouple Type-K Accuracy - ± 1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)