Fluke 750P Pressure Module
The Fluke 750P Pressure Module are precision pressure modules available in different pressure ranges, covering workloads from 1 in H20 to 10,000 psi (2.5mBar to 700bar). Using the 750P, allows for the user to turn their Fluke multifunction calibrator into a fully fledged pressure calibrator. Compatible with the Fluke 725, 726 and 750 Series Calibrators, the 750P extends the measurement range of the pressure calibrator. The pressure modules are calibrated independently so they can be swapped from one calibrator to another with the loss or accuracy or traceability.
Fluke 750P Pressure Module Comparison
Available as a gage, differential, dual range and high pressure models with each module selectable from the drop down box above with the range, over pressure and media compatibility shown below:
Model |
Parameter/Range |
Burst rating |
Hi side media |
Lo side media |
Reference uncertainty |
Total uncertainty 1 year |
Total uncertainty 1 year |
Total uncertainty 6-month |
Total uncertainty 6-month |
Differential Module |
750P00 |
0 to 1 in H2O (0 to 2.5 mBar) |
30X |
Dry air |
Dry air |
±0.15% |
(15ºC-35ºC): ±0.3% |
±0.35% |
(15ºC-35ºC): ±0.25% |
±0.30% |
750P3IN |
0 to 3 in H2O (0 to 7.5 mBar) |
10X |
Dry air |
Dry air |
±0.15% |
(15ºC-35ºC): ±0.3% |
±0.35% |
(15ºC-35ºC): ±0.25% |
±0.30% |
750P5IN |
0 to 5 in H2O (0 to 12.5 mBar) |
6X |
Dry air |
Dry air |
±0.15% |
(15ºC-35ºC): ±0.3% |
±0.35% |
(15ºC-35ºC): ±0.25% |
±0.30% |
750P01 |
0 to 10 in H2O (0 to 25 mBar) |
3X |
Dry air |
Dry air |
±0.050% |
(15ºC-35ºC): ±0.2% |
±0.3% |
(15ºC-35ºC): ±0.15% |
±0.25% |
750P02 |
0 to 1psi (0 to 70 mBar) |
3X |
Dry air |
Dry air |
±0.050% |
(15ºC-35ºC): ±0.1% |
±0.15% |
(15ºC-35ºC): ±0.075% |
±0.25% |
750P22 |
0 to 1psi (0 to 70 mBar) |
3X |
316 SS |
Dry air |
±0.050% |
(15ºC-35ºC): ±0.1% |
±0.15% |
(15ºC-35ºC): ±0.075% |
±0.25% |
750P03 |
0 to 5 psi (0 to 350 mBar) |
3X |
Dry air |
Dry air |
±0.02% |
(15ºC-35ºC): ±0.04% |
±0.3% |
(15ºC-35ºC): ±0.15% |
±0.25% |
750P23 |
0 to 5 psi (0 to 350 mBar) |
4X |
316 SS |
Dry air |
±0.02% |
(15ºC-35ºC): ±0.04% |
±0.3% |
(15ºC-35ºC): ±0.15% |
±0.25% |
750P04 |
0 to 15 psi (0 to 1 Bar) |
43 |
Dry air |
Dry air |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.0045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P24 |
0 to 15 psi (0 to 1 Bar) |
4X |
316 SS |
Dry air |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.0045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
Gage Module |
750P05 |
0 to 30 psi (0 to 2 Bar) |
4X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P06 |
0 to 100 psi (0 to 7 Bar) |
4X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P27 |
0 to 300 psi (0 to 20 Bar) |
4X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P07 |
0 to 500 psi (0 to 35 Bar) |
4X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P08 |
0 to 1000 psi (0 to 70 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P09 |
0 to 2000 psi (0 to 140 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P09 |
0 to 1500 psi (0 to 100 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P2000 |
0 to 2000 psi (0 to 140 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
High pressure module |
750P29 |
0 to 3000 psi (0 to 200 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P30 |
0 to 5000 psi (0 to 340 Bar) |
3X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
750P31 |
0 to 10000 psi (0 to 700 Bar) |
2X |
316 SS |
N/A |
±0.0175% |
(15ºC-35ºC): ±0.035% |
±0.045% |
(15ºC-35ºC): ±0.03% |
±0.04% |
Although the 750P modules are more accurate if used indoors, they are designed and specified to be able to deliver traceable pressure measurement data in environments from -10ºC to +50ºC. The 750P can reduce error by digitally sending measurements to calibrators with precision measurements up to 0.01%.
Using the 750P users are able to choose the module that best suits their needs that enable gage, differential and absolute pressure measurements. The 750P boasts a number of features including 0.025% reference uncertainty and 6-month and 1-year specifications.
The 750P Pressure Modules are simple to use, measuring pressure can be conducted by connecting the pressure module to a pressure source hand pump and then connect the pressure module cable to the calibrator. At the touch of a button, pressure can be displayed in top to 11 different engineering units. When used alongside the 750 Series Documenting Process Calibrators, pressure readings can be date/time stamped and stored electronically.
With its over moulding rugged construction, the 750P protects against shock if accidentally dropped with protection from dirt, dust and moisture ingress. Each module comes with a Pressure connections are 1/8” NPT female connection. A ¼” NPT Male, ¼” BSP/ISO and M20 male adapter. A one metre cable between the pressure module and calibrator reduces the length on connecting tubing to the pressure source. A remote pressure head provides extra margin of safety and conveniences a result of removing the calibrator and operator from the pressure source in the event of need for semi-remote measurements.
Fluke Premium Care
The Fluke 750P Pressure Module is compatible with Fluke Premium Care that provides coverage above and beyond the original product warranty. With the Fluke Premium Care Plan the calibration, repair, collection and delivery of the Fluke 750P will be expedited, reducing the downtime for the user.
Simply check the one year or three year service plan when placing your order, and your new analyser will be protected with Fluke premium care.
Standard warranty vs Fluke Premium care
|
Standard Warranty |
Fluke Premium Care |
Repair manufacturing defects |
✔ |
✔ |
Annual calibration |
|
✔ |
Accidental damage and repair of main unit |
|
✔ |
Expedited calibration and repair |
|
✔ |
Expedited freight |
|
✔ |
Replacement or repair of damaged accessories |
|
✔ |
Priority Tech Support |
|
✔ |