Specification
Fluke 789 ProcessMeter Specifications
- Measurement Function/Range and Resolution/Best Accuracy (% of reading + LSD)
- V dc/400.0mV, 4.000V, 40.00V, 400.0V, 1000V/0.1% + 1
- V ac (true-rms)/400.0mV, 4.000V, 40.00V, 400.0V, 1000V/0.7% + 2
- mA dc/30.000mA/.05% + 2
- A dc/1.000A (0.440 A continuous)/0.2% + 2
- A ac/1.000A (0.440 A continuous)/1% + 2
- Resistance/400.0hms/4.000k, 40.00k, 400.0k, 4.0M, 40M/0.2% + 1
- Frequency (0.5Hz to 20kHz)/199.99Hz, 1999.9Hz, 19.999kHz/.005% + 1
- Diode Test/2.000V (shows diode voltage drop)/2% + 1
- Continuity/Beeps for resistance < approx. 100ohms/-
- Output Function/Range and Resolution/Drive Capability/Accuracy (% of span)
- DC current output (internal battery operation)/0.000 to 20.000mA or 4.000 to 20.000mA, (selectable at power-up) Over range to 24.000mA/24V compliance or, 1,200ohms, at 20mA/.05%
- DC current simulate (Ext. 15V to 48V loop supply)/0.000 to 20.000mA or 4.000 to 20.000mA, (selectable at power-up) Over range to 24.000mA/1000ohms, at 20mA/.05%
- 24V loop supply/Minimum 24V/250ohms at 20mA/>24V
- Current adjustment modes
Manual: Coarse, Fine, 25% and 100% step Automatic: Slow Ramp, Fast Ramp, 25% step
- Maximum voltage applied between any jack and earth ground - 1000V RMS
- Storage temperature - -40°C to 60°C
- Operating temperature - -20°C to 55°C
- Temperature coefficient - 0.05 x (specified accuracy) per °C (for temperatures<18°C or >28°C)
- Relative humidity - 95% up to 30°C; 75% up to 40°C; 45% up to 50°C;35% up to 55°C
- Vibration - Random, 2g, 5-500Hz
- Shock - 1 meter drop test
- Safety - IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000V
- Size (HxWxL) - 50mm x 100mm x 203mm (1.97in x 3.94in x 8.00in)
- Weight - 600g (1.3lbs)
- Battery - Four AA alkaline batteries
- Battery life - 140 hours typical (measurement), 10 hours typical (sourcing 12mA)
- Warranty - Three years
Fluke IR300FC Connector Specifications
- Battery type - Two AAA Alkaline batteries, ANSI-24A IEC-LRO3
- Battery life - 6 hours of continuous transmission
- RF communications - 2.4GHz ISM Band
- RF communication range -
Open air, unobstructed - up to 20m Obstructed, sheetrock wall - up to 6.5m Obstructed, concrete wall or steel electrical enclosure - up to 3.5m
- Temperature operating - -10°C to 50°C
- Storage - -20°C to 60°C
- Certifications - CSA, FCC, CE, IC
- Warranty - Three years
- Weight - 80g
- Size (HxWxL) - 3.2 x 7.6 x 6.4cm (1.25 x 3.0 x 2.5in)
- Compatibility - Fluke 287, 289, 789
Fluke A3004FC Clamp Meter Specifications
DC Current Function
- Range -
0.05mA to 20.99mA DC 21.0mA to 99.9mA DC
- Resolution -
0.01mA 0.1mA
- Accuracy -
0.2% ± 5 digits 1.0% ± 5 digits
Specifications
- LCD w/backlight - 3 1/2 digits
- Log rate/interval - 1 sec minimum/adjustable by PC or front pannel
- Battery type
2 AA NEDA 15A IEC LR6
- Battery life - 45 hours
- Memory - Record up to 65,000 readings
- RF communications - 2.4GHz ISM Brand
- RF communication range -
Open air, unobstructed, up to 20m Obstructed, sheetrock wall, up to 6.5m Obstructed, concrete wall or steel electrical enclosure, up to 3.5m
- Operating temperature - -10°C to 50°C
- Storage temperature - -40°C to 60°C
- Temperature coefficient - add 0.1X (specified accuracy)/°C (<18°C or > 28°C)
- Operative humidity -
90% at 35°C 75% at 40°C 45% at 50°C
- Altitude -
Operating - 2,000m Storage - 12,000m
- EMC - EN 61326-1:2013
- Maximum voltage between terminal and earth ground (module) - 30V DC or AC rms
- Certifications -
CSA C-US CE FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection - IP42
- Jaw opening - 4.5mm
- Size (HxWxD) - 16.5mm x 6.35cm x 1.4cm (6.5in x 2.5in x 1.4in)
- Weight - 0.299kg (0.8lb)
|