Keller LEX1 Ei (400bar) Intrinsically Safe Digital Manometer

SKU: KELL303030.2004

Never Beaten On Price

 

We’re always working hard to give you the best possible price, but if you find it cheaper somewhere else, we’ll endeavour to match the price.

 

Call 0113 248 9966 or contact us online

Typically ships in 5-7 working days
Recommended Add-ons
Need Some Help From Our Experts? chevron-right chevron-down

We're always happy to offer help, information & advice to find the right instrument for you, so please get in touch.

 

To speak to our sales team, call us on 0113 248 9966, use our Live Chat service or contact us online.

Members earn 780 reward points chevron-right chevron-down

Use reward points to get money off future purchases.

 

Please note: Customers must be signed into their account to be elegible. Find out more about reward points here.

FREE Delivery & 60 Day Returns chevron-right chevron-down

We offer FREE standard delivery on all orders over £249, with a range of next-day options also available on many items.

 

Find out more on our delivery information page.

Key Features
  • Pressure range of 0 to 400bar, accuracy of ±0.05% FS, and resolution of 20mbar
  • Intrinsically safe with classification of Ex II 2 G and Ex ia IIC T6 Gb
  • IP65 ingress protection rating, battery life of 2000 hours

Keller LEX1 Ei Intrinsically Safe Digital Manometer (400bar)

The Keller LEX1 Ei Intrinsically Safe Digital Manometer has an absolute pressure measurement range of 0 to 400bar with an accuracy of ±0.05% FS and a resolution of 20mbar. It is suitable for specialist applications including calibration and laboratory use and takes measurements via a G ¼” male connector.

The Keller LEX1 Ei is an intrinsically safe instrument and is therefore safe to use in hazardous environments where there is a risk of combustion. It has an intrinsically safe classification of zone 1: Ex II 2 G and Ex ia IIC T6 Gb and certification files PTB 05 ATEX 2012 X and IECEx PTB 13.0028 X.

Pressure readings are available in a number of different units on the Keller LEX1 Ei’s clear digital screen. It has a digital calibration function with a zero point and end point whilst the min/max recording feature captures extreme values.

The Keller LEX1 Ei is capable of communicating with a monitoring network over its RS485 Fischer connection, however a Keller K114A Cable Adaptor is needed for this function. Keller CCS30 software – available for free from the Keller website – can be used to coordinate the system with up to 128 instruments in a Keller-Bus protocol.

The Keller Lex1 Ei has just two buttons, which makes operation very easy, and also boasts an IP65 rating and a 2000-hour battery life.

Keller part number: 303030.2004

Key Features

  • Intrinsically safe
  • Suitable for calibration
  • Suitable for laboratories
  • Range: 0 to 400bar
  • Accuracy: ±0.05% FS
  • Resolution: 20mbar
  • Digital calibration feature
  • Works in wider monitoring system
  • IP65 ingress protection rating
  • 2000-hour battery life
  ECO2 LEO1 LEO2 LEO3 LEO5 LEO Record LEX1
-1 to 3bar ✔ ✔ ✔ ✔ ✔ ✔
-1 to 30bar ✔ ✔ ✔ ✔ ✔ ✔ ✔
0 to 100bar ✔
0 to 300bar ✔ ✔ ✔ ✔ ✔ ✔ ✔
0 to 400bar ✔
0 to 700bar ✔ ✔ ✔ ✔ ✔
0 to 1000bar ✔ ✔ ✔ ✔
Accuracy ±0.5% FS ±0.1% FS ±0.1% FS ±0.1% FS ±0.05% FS ±0.1% ±0.05% FS
Resolution(at smallest range) 10mbar 1mbar 1mbar 1mbar 1mbar 1mbar 0.1mbar
Temperature range 0˚C to 50˚C
Temperature accuracy ±1˚C
Intrinsically safeversion ✔ ✔ ✔ ✔ ✔
Peak mode ✔ ✔
Pressure connector 7/16" UNF G 1/4" 7/16" UNF G 1/4" G 1/4" G 1/4" G 1/4"
Analogue output ✔ ✔
Internal memory ✔ ✔ ✔
Data port RS485 Binder USB RS485 Fischer RS485 Fischer
Compatible withKeller-Bus protocol ✔ ✔ ✔
Show Trustpilot Reviews
Specification
No

Intrinsically Safe Categorisation

  • Classification: Zone 1: Ex II 2 G Ex ia IIC T6 Gb
  • Certification files: PTB 05 ATEX 2012 X and IECEx PTB 13.0028 X

Performance

  • Absolute pressure range: 0 to 400bar
  • Overpressure: 800bar
  • Resolution: 20mbar
  • Accuracy @ RT (20˚C to 25˚C): ≤±0.05% FS. Nonlinearity (BFSL), pressure hysteresis, non-repeatability, zero point, amplification.
  • Total error band (0˚C to 50˚C): ≤±0.05% FS. Max. deviation within the specified pressure and temperature range.
  • Long-term stability: ±0.1% FS. > 1 bar, per year under reference conditions, yearly recalibration recommended.
  • Long-term stability: ±0.1mbar. ≤ 1 bar, per year under reference conditions, yearly recalibration recommended.
  • Degree of dependency on location: <±1.5mbar. Calibrated in vertical installation position with pressure connection facing downwards.
  • Accuracy of temperature measurement: ±1˚C typ.
  • Pressure range reserve: ±10%

Electrical Data

  • Battery: 3 V, type CR2430. LEX1 Ei only permitted for use in haz- ardous atmospheres when used with the Renata CR2430
  • Battery life: Approx. 2000 hours when used continuously
  • External power supply: 8...28 VDC
  • Overvoltage protection and reverse polarity of external power supply: ± 32 VDC
  • RS485 voltage insulation: -7...+12 VDC
  • GND case insulation: > 10 MΩ @ 50 VDC
  • External interface: RS485 half-duplex
  • Interface measuring rate: 30 measurements per second
  • Electrical connection: Fischer D 103 A054-130
  • CE conformity as per 2014/30/EU (EMC): EN 61000-6-1 to -6-4; EN 61326-1 / EN 61326-2-3

Temperature Range

  • Compensated temperature range: 0...50 °C
  • Media temperature: 0...50 °C
  • Ambient temperature: 0...50 °C
  • Storage temperature: -20...70 °C

Display

  • Dimensions/appearance: See Dimensions & options
  • Number of digits on LC display: 2 rows with 5 digits each
  • Display mode: Pressure + min/max or pressure + temperature
  • Measuring rate: 2 measurements per second
  • Configurable units of pressure: [bar], [mbar], [hPa], [kPa], [MPa], [PSI], [mH2O], [cmH2O], [inH2O], [ftH2O], [mmHg], [inHg], [kp/cm2]
  • Additional units of pressure: 5 user-defined units can be configured

Mechanical data

  • Pressure connection: Stainless steel AISI 316L
  • Pressure transducer separating diaphragm: Stainless steel AISI 316L
  • Pressure transducer seal (internal): FKM (Viton® type A)
  • Pressure connection seal (external): FKM (Viton® type A)
  • Display housing: Faradex AS-1003
  • Oil filling sensor: Silicone oil
  • Pressure connection: G1/4, see Dimensions & options
  • Diameter x height x depth (approx.): 76 x 118 x 55 mm
  • Weight (approx.): 300 g
  • Protection: IP65
Label Type Size Download