Metrel A1322 Active 3-Phase Adaptor

SKU: METRA1322

Never Beaten On Price

 

We’re always working hard to give you the best possible price, but if you find it cheaper somewhere else, we’ll endeavour to match the price.

 

Call 0113 248 9966 or contact us online

Typically ships in 3-5 working days
Need Some Help From Our Experts? chevron-right chevron-down

We're always happy to offer help, information & advice to find the right instrument for you, so please get in touch.

 

To speak to our sales team, call us on 0113 248 9966, use our Live Chat service or contact us online.

Members earn 2142 reward points chevron-right chevron-down

Use reward points to get money off future purchases.

 

Please note: Customers must be signed into their account to be elegible. Find out more about reward points here.

FREE Delivery & 60 Day Returns chevron-right chevron-down

We offer FREE standard delivery on all orders over £249, with a range of next-day options also available on many items.

 

Find out more on our delivery information page.

Key Features
Professional 3 Phase PAT testing, 3 Phase RCD testing & Differential Earth Leakage Adaptor for use with Metrel Testers

Metrel A1322 Active 3-Phase Adaptor

Metrel’s all new A 1322 Multifunctional 3 Phase test adapter is designed for troubleshooting, as well as for periodic testing on 3-phase appliances and machinery.

Unique functions such as, active polarity testing, differential leakage testing and testing of 3-phase RCD’s make the A1322 Active 3-phase Adapter an ideal instrument for advanced applications. The Metrel A1322 adapter is designed for use alongside the MI3321 MultiservicerXA, SigmaPAT & DeltaPAT enabling functional tests to be carried out on machines up to 40A. Several test socket outlets make this instrument an ideal tester for testing industrial extension leads that may also be RCD protected. Due to the powerful test data management included with both supporting test instruments, all test data can easily be equipped with needed parameters. This data can be stored into the large memory included, and with the support of the powerful data management system PC SW Patlink Pro, exported as professional test reports.

  • All tests on 3-phase electrical equipment
  • 3 Phase Live leakage test
  • 3 Phase differential Leakage Testing
  • Insulation Resistance
  • 3 Phase Power testing (kVA, kW, kVAr & Cos)
  • RCD (3-Phase P/RCD Testing) Type (AC,A,B, PRCD-S & P/RCD-K)
  • Simple connection to the PAT/MACHINE tester with automatic detection
  • Simple test procedures, identical to single phase equipment
  • Test sequence for 3-phase tests are automatically set, based on entered test codes and input voltages
  • Built-in CEE 3-PH/32A 5 pin, CEE 3-PH/16A 5 pin and CEE 1-PH/16A 3 pin test sockets
  • Robust waterproof case
Show Trustpilot Reviews
Specification
Yes

Differential leakage current (230/400 VAC or 120/208 VAC)

  • Differential leakage current accuracy: 0.00 mA ÷ 9.99 mA 0.01 mA ±(5 % of reading + 5 digits)
  • Power / Functional test (230/400 VAC or 120/208 VAC)
  • Apparent power accuracy: 0.00 kVA ÷ 24.29 kVA 0.01 kVA ±(5 % of reading + 5 digits)
  • Active power readout Range Resolution Accuracy 0.00 kW ÷ 24.29 kW 0.01 kW ±(5 % of reading + 5 digits)
  • Reactive power readout Accuracy 0.00 kW ÷ 24.29 kVAr 0.01 kVAr ±(5 % of reading + 5 digits)
  • Power factor readout Range Resolution Accuracy 0.00 ÷ 1.00 0.01 ±(5 % of reading + 5 digits)
  • 3-phase RCD / Test current (10 mA, 15 mA, 30 mA, 100 mA, 300 mA)
  • Portable RCD trip-out time readout (AC and A type PRCD)
  • Range Resolution Accuracy
  • 0 ms ÷ 300 ms (½ x IΔN, IΔN ) 1 ms
  • 0 ms ÷ 150 ms (2 x IΔN) 1 ms ±3 ms
  • 0 ms ÷ 40 ms (5 x IΔN) 1 ms
  • Portable RCD trip-out current readout (B type PRCD)
  • Range Resolution Accuracy
  • 0.2 x IΔN ÷ 2.2 x IΔN 0.05 x IΔN ±0.1 x IΔN
  • Polarity test Standard test (<60 VAC and DC)
  • Polarity test Active (Mains supply voltage, over-current protection)

General data

  • Supply voltage single-phase 230 V ±10 %
  • Supply voltage 3-phase 230/400 V ±10 %
  • 120/208 V ±10 %
  • Maximum test current 32 A, 40 A max (10 min)
  • Overvoltage category 300 V/CAT II
  • Protection classification I
  • Pollution degree 2
  • Protection degree IP 65 (closed and locked cover) / IP 20 (connectors)
  • Case Shock proof plastic, portable
  • Dimensions: 335 mm x 160 mm x 335 mm
  • Weight (without accessories) 7.2 kg