Metrel MI 3288 Earth Insulation Tester

SKU: METRMI3288-CONF
  • Perform all primary types of earth measurement with one instrument
  • Programmable auto sequences
  • Wide range of insulation test voltages - 50V to 2500V
More Info

Metrel MI 3288 Earth Insulation Tester

The Metrel MI 3288 Earth Insulation Tester is a portable, battery powered tester able to measure earth resistance, specific earth resistance (Wenner & Schlumberger method), earth potential, step and touch voltages, insulation resistance and continuity of protection conductors. With its vast array of testing functionalities, the MI 3288 is a truly versatile instrument that is able to perform all of the main types of earth test and measurement.

In addition to the aforementioned testing functionalities, the MI 3288 also offers 4-wire earth resistance measurement, TRMS current measurement and one clamp or two clamp earth resistance measurement. Programmable auto sequences are also a feature of this unit alongside support for single or automated measurements. For users safety, a high degree of protection is also offered when using the device, with over voltage protection category 600 V CAT II/300 V CAT III at 4000M above sea level.

The MI 3288 is also convenient to use, with a number of design features intended to promote an intuitive user experience. The large tactile buttons control a simple grid user interface. The 4.3” colour LCD display is touchscreen, with results clearly visible due to the powerful backlight. Bluetooth enables communication with external devices, with results able to be downloaded to PC with the help of Metrel ED Manager software, enabling further evaluation and reporting of collected data.

Common applications for the MI 3288 include initial/installation testing and periodic testing of domestic or industrial installations, in addition to small buildings and mining facilities.

The Metrel MI 3288 is a great addition to the MI tester range. With its full range of earth testing and measurement features, it makes a convincing buy for anyone working extensively with this functionality. The standard kit is completed by the inclusion of a carry bag and full set of test leads and clips; 20M/50M kits comes with a different length test lead set and other accessories as shown below.

  Standard Kit 20M Kit 50M Kit
MI 3288 Earth Insulation Tester
Battery Pack 7.2V 4400 mAH
Power supply adapter 12V/3A
2.5kV test lead - 2 x 1.5M
Test Lead green 1.5M
Test lead, 4 x 1M
Test probe, 2pcs (black, blue, green, red)
Soft carrying bag
Soft carrying neck belt
USB cable
PC SW Metrel ES Manager Basic licence
Short instruction manual
Calibration cert
2 x Test lead 20m    
2 x Test lead 50m    
2 x Test lead 4.5m  
4 x Earth rod

 

Key Features

  • Perform all primary types of earth measurement with one instrument
  • 4.3” colour LCD touchscreen display
  • Programmable auto sequences
  • High degree of protection
  • 600 V Cat II/ 300 V CAT III over voltage cat
  • Wide range of insulation test voltages - 50V to 2500V
  • Integrated charger and rechargeable lithium ion batteries
  • Bluetooth communication with PC, Android tablets and smartphones
  • Selective earth resistance with 1 clamp
  • Step and voltage measurement with external p/s probe
  • Varistor test 2.5kV
  • Current measurements with clamps AC
  • TRMS voltage & frequency measurements
  • Low Ohm measurements with 7mA and 200mA DC test current

What's In The Box?

  • Metrel MI 3288 Earth Insulation Tester
  • Battery pack 7, 2V 4400 mAh
  • Power supply adapter 12 V/3 A
  • 2,5kV test lead, 2 x 1.5M
  • Test lead, 1.5M
  • Test lead, 4 x 1M
  • Test probe, 2 pcs (red, black)
  • Crocodile clip, 4 pcs (black, blue, green, red)
  • Soft carrying bag
  • Soft carrying neck belt
  • USB cable
  • PC SW Metrel ES manager BASIC licence
  • Short instruction manual
  • Instruction manual (on CD)
  • Calibration certificate
Specification
  • Insulation resistance Riso Un = 2,5 kV. Measurement range/resolution/accuracy: 0 kΩ... 999 kΩ/1 kΩ, 1.00 MΩ ... 9.99 MΩ/0.01 MΩ/±(3 % of reading + 3 digits), 10.0 MΩ ... 99.9 MΩ/0.1 MΩ/±(3 % of reading + 3 digits), 100 MΩ ... 999 MΩ/1 MΩ/±(3 % of reading + 3 digits), 1.00 GΩ ... 9.99 GΩ/10 MΩ/±(5 % of reading + 3 digits) , 10.0 GΩ ... 99.9 GΩ/100 MΩ/±(15 % of reading + 1 digit)
  • Continuity 200 mA of PE conductor with polarity change. Measurement range/resolution/accuracy: 0.020 Ω ... 1.999 Ω/0.001 Ω/±(1 % of reading + 2 digits), 2.00 Ω ... 19.99 Ω/0.01 Ω/±(1 % of reading + 2 digits), 20.0 Ω ... 999.9 Ω/0.1 Ω/±(1 % of reading + 2 digits), 1.000 kΩ ... 1.999 kΩ/1 Ω/±(1 % of reading + 2 digits),
  • Low resistance continuity measurement, test current 7 mA (continuous measurement). Measurement range/resolution/accuracy: 0.0 Ω ... 199.9 Ω /0.1 Ω /±(0,5 % of reading + 5 digits), 200 Ω ... 1,999 kΩ /1 Ω /±(0,5 % of reading + 5 digits), 2.00 kΩ ... 19.99 kΩ/10 Ω/±(0,5 % of reading + 5 digits), 20.0 kΩ ... 199.9 kΩ/100 Ω/±(0,5 % of reading + 5 digits), 200 kΩ ... 999 kΩ/1 kΩ/±(2 % of reading + 5 digits),
  • Earth resistance 4-wire method test frequency 55 – 164 Hz. Measurement range/resolution/accuracy: 0.010 Ω ... 1.999 Ω/0.001 Ω/±(3 % of reading + 3 digits), 2.00 Ω ... 19.99 Ω /0.01 Ω /±(3 % of reading + 3 digits), 20.0 Ω ... 199.9 Ω /0.1 Ω /±(3 % of reading + 3 digits), 200 Ω ... 999 Ω /1 Ω /±(3 % of reading + 3 digits), 1.000 kΩ ... 1.999 kΩ/0.001 kΩ /±(3 % of reading + 3 digits), 2.00 kΩ ... 19.99 kΩ/0.01 kΩ/±(3 % of reading + 3 digits)
  • Earth resistance 4-wire method with one current clamp - Selective. Measurement range/resolution/accuracy: 0.010 Ω ... 1.999 Ω/0.001 Ω /±(8 % of reading + 3 digits), 2.00 Ω ... 19.99 Ω /0.01 Ω /±(8 % of reading + 3 digits), 20.0 Ω ... 199.9 Ω /0.1 Ω /±(8 % of reading + 3 digits), 200 Ω ... 999 Ω /1 Ω/±(8 % of reading + 3 digits), 1.000 kΩ ... 1.999 kΩ/0.001 kΩ/±(8 % of reading + 3 digits), 2.00 kΩ ... 19.99 kΩ /0.01 kΩ /±(8 % of reading + 3 digits),
  • 2-clamp earth resistance measurement. Measurement range/resolution/accuracy: 2.00 Ω ... 9.99 Ω /0.01 Ω /±(5 % of reading + 2 digits), 10.0 Ω ... 49.9 Ω/0.1 Ω/ ±(10 % of reading + 2 digits), 50 Ω ... 100 Ω /1 Ω/±(20 % of reading)
  • Specific earth resistance Ro Wenner and Schlumberger method. Measurement range/resolution/accuracy: 0.00 Ωm ... 19.99 Ωm /0.01 Ωm/calculated value (consider uncertainty of 4 – pole measurement), 20.0 Ωm ... 199.9 Ωm /0.1 Ωm /calculated value (consider uncertainty of 4 – pole measurement), 200 Ωm ... 999 Ωm /1 Ωm /calculated value (consider uncertainty of 4 – pole measurement), 1.000 kΩm ... 1.999 kΩm/0.001 kΩm /calculated value (consider uncertainty of 4 – pole measurement), 2.00 kΩm ... 19.99 kΩm/0.01 kΩm /calculated value (consider uncertainty of 4 – pole measurement), 20.0 kΩm ... 199.9 kΩm/0.1 kΩm /calculated value (consider uncertainty of 4 – pole measurement), 200 kΩm ... 999 kΩm /1 kΩm /calculated value (consider uncertainty of 4 – pole measurement), 1.0 MΩm ... 1.99 MΩm /10 kΩm/calculated value (consider uncertainty of 4 – pole measurement),
  • Earth potential - voltage. Measurement range/resolution/accuracy: 0.00 mV ... 99.99 mV/0.01 mV/±(1 % of reading + 3 digits), 100.0 mV ... 999.9 mV/0.1 mV/±(1 % of reading + 3 digits), 1.000 V ... 9.999 V/1 mV/±(1 % of reading + 3 digits), 10.00 V ... 49.99 V/10 mV/±(1 % of reading + 3 digits),
  • Step and Touch. Measurement range/resolution/accuracy: 0.1 V ... 199.9 V/0.1 V/calculated value, 200 V ... 999 V/1 V/calculated value,
  • Voltage TRMS. Measurement range/resolution/accuracy: 0.000 V ... 9.999 V/0.001 V/Range: 15 ... 99 Hz - ±(0.5 % of reading + 3 digits), 10.00 V ... 99.99 V/0.01 V/Range: 100 ... 399 Hz - ±(1 % of reading + 3 digits), 100.0 V ... 749.9 V /0.1 V/Range: 400 ... 1200 Hz - ±(5 % of reading + 3 digits),
  • Voltage DC. Measurement range/resolution/accuracy: 0.000 V ... 9.999 V/0.001 V/±(0.5 % of reading + 3 digits), 10.00 V ... 99.99 V/0.01 V/±(0.5 % of reading + 3 digits), 100.0 V ... 999.9 V /0.1 V/±(0.5 % of reading + 3 digits),
  • Frequency. Measurement range/resolution/accuracy: 15.00 Hz ... 99.99 Hz/0.01 Hz/±(0.2 % of reading + 1 digit), 100.0 Hz ... 999.9 Hz/0.1 Hz/±(0.2 % of reading + 1 digit), 1000 Hz ... 1200 Hz/1 Hz/±(0.2 % of reading + 1 digit),
  • Current with A 1281 Current clamp. Measurement range/resolution/accuracy: 10 mA ... 749 mA/1 mA/±(2.5 % of reading + 3 digits), 0.10 A ... 7.49 A/0.01 A/±(2.5 % of reading + 3 digits), 2.0 A ... 99.9 A/0.1 A/±(2.5 % of reading + 3 digits), 100 A ... 149 A/1 A/±(2.5 % of reading + 3 digits), 20 A ... 999 A/1 A/±(2.5 % of reading + 3 digits),
  • Varistor Test. Measurement range/resolution/accuracy: 0.0 V .... 99.9 V /0.1 V/±(1 % of reading + 3 digits), 100 V .... 999 V /1 V/±(1 % of reading + 3 digits), 1.00 kV .... 2.50 kV /10 V /±(1 % of reading + 3 digits),