Radiodetection CAT4+ & Genny4 Cable Avoidance Kit (Choice Of Kit)

SKU: RADICATPLUSGENNY4KIT-CONF
  • With an in-built depth function, the instrument will display a depth indication to a located utility, making it easier to find
  • The CAT4+ & Genny4 Cable Avoidance Kit is available in four different variations, with each including a Genny4 and accessories
  • An in-built 'Strike Alert' function displays the location of utilities buried at shallow depth, which could be struck if undetected
More Info
Choose Your Free Gift

Limited-time offer: purchase any Radiodetection C.A.T & Genny Kit and get a FREE 4” Genny Clamp or Standard 33kHz Sonde accessory.
HURRY! While stocks last.

Radiodetection CAT4+ & Genny4 Cable Avoidance Kit

The Radiodetection CAT4+ & Genny4 Cable Avoidance Kit enables users to detect, assess, and map underground utilities such as pipes, building structures, telecom/data cables, and electrical lines. When paired with the Genny4 Signal Generator, the CAT4+ can locate hidden utilities that would not emit sufficient electromagnetic or radio signals on their own. Additionally, the CAT4+ features 'StrikeAlert' software, which provides a clear visual warning of shallow utilities that could pose a risk if overlooked.

In addition to these features, the CAT4+ offers a depth function. When operating in 'Genny mode' (which requires the use of the Genny4), the device provides a depth indication for the detected utility service.

The CAT4+ can be used in 4 different modes, which are:

  • Avoidance mode: Simultaneously detects Genny, power, and radio signals
  • Power mode: Detects electromagnetic fields (EMFs) around buried electrical supply cables
  • Radio mode: Detects long-range radio signals transmitted through buried pipes and cables
  • Genny mode: Used with the optional Radiodetection Genny4 Signal Generator to detect generated signals. When used with the CAT4+, it also displays the depth of buried utilities

The CAT4+ is equipped with 'Dynamic Overload Protection', allowing it to filter out unwanted electrical noise, commonly found near electrical substations and surface-mounted high-voltage (HV) cables. The device displays signal strength on a high-contrast, backlit LCD screen, featuring a bar graph for quick and easy pinpointing of hidden utilities.

The Genny4 Signal Generator

The Genny4 provides users with a dual-frequency signal output, including a 33kHz locate signal for general utility tracing and an additional frequency tailored to locate smaller cables like telecom, data, and street lighting lines. For more complex applications, the Genny4's power boost function allows the signal to penetrate deeper and travel further underground, enhancing its ability to couple with utilities. A high-strength neodymium magnet ensures secure attachment to buried utility cables via metallic street furniture.

When used together, the CAT4+ and Genny4 produce an industry-leading cable avoidance tool for use in a plethora of environments and testing sights. The CAT4 is also available as a CAT4+ or a gCAT4+, with the below table highlighting the key differences between the 3 models.

Radiodetection C.A.T4 range comparison matrix

  C.A.T4 C.A.T4+ gC.A.T4+
Avoidance mode
Genny signal locate
Power signal locate
Radio signal locate ✔  ✔ 
Smaller diameter locate frequency ✔ 
eCert
Dynamic overload protection
Depth  
StrikeAlert
Data aquisition    
 Service due indicator    
 SWING warning    
 CALSafe    
 Bluetooth (for future use)    
 GPS/GNSS    

The CAT4+ Accessory Packs

Four different options are available for the CAT4+ and Genny4 Kit, which are as follows:

  • CAT4+ with Genny4 Signal Generator
  • CAT4+ with Genny4 Signal Generator & Carry Bag
  • Electricians Accessory Pack - features a Genny4, a live plug connector (UK Plug), 100m (4") clamp and a soft carry case
  • Builders Accessory Pack - features a Genny4, a standard 33kHz Sonde, M10 spring, 100mm (4") clamp, and a soft carry case
  Genny4 Signal Generator Genny4 and Carry Bag Electricians Accessory Pack Builders Accessory Pack
CAT4+
Genny4
Carry Bag X X X
Soft Carry Case X X
Live Plug Connector (UK) X X X
100mm (4") Clamp X X
Standard 33kHz Sonde X X X
M10 Spring X X X

Key Features

  • Accurately detect underground cables, pipes and structures
  • High contrast, backlit LCD display
  • Network Rail approved
  • ‘StrikeAlert’ function that displays the location of services underground, which could cause a ‘strike’ risk if undetected
  • Power mode - detects EMF around cables
  • Radio mode - detects long-range radio signals
  • Avoidance mode - detects Jenny, power and radio signals simultaneously
  • Features a depth function which, when used in 'Genny Mode', will display a depth location of the utility

What's In The Box?

CAT4+ with Genny4 Signal Generator

  • Radiodetection CAT4+ Cable Avoidance Tool
  • Genny4 Signal Generator

CAT4+ with Genny4 Signal Generator & Carry Bag

  • Radiodetection CAT4+ Cable Avoidance Tool
  • Genny4 Signal Generator
  • Carry Bag

Electricians Accessory Pack

  • Radiodetection CAT4+ Cable Avoidance Tool
  • Genny4 Signal Generator
  • Live Plug Connector (UK Plug)
  • 100mm (4") Clamp
  • Soft Carry Case

Builders Accessory Pack

  • Radiodetection CAT4+ Cable Avoidance Tool
  • Genny4 Signal Generator
  • Standard 33kHz Sonde
  • M10 Spring
  • 100mm (4") Clamp
  • Soft Carry Case
Specification
  • Power signals (P): freq - 50Hz-1.5kHz, sensitivity - 3mA, locating depth(m) - 3 - 2
  • Radio signals (R): freq - 15kHz-30kHz, sensitivity - 25μA, locating depth(m) - 2 - 1
  • Genny4 signals (G): freq - 32.768kHz ±20Hz/131.072kHz ±20Hz, sensitivity - 5 μA, locating depth(m) - 4 - 2
  • Avoidance mode (A):freq - P + R + G as above, as above, sensitivity - 4 - 2
  • Dynamic range: 120dB @ 10Hz
  • Dynamic overload protection: 40dB @ 50Hz
  • Locate accuracy: ±10% of depth
  • Depth accuracy (on undistorted signal and with no adjacent signals): Line - 5% 0.1m to 3mm, Sonde: 5% 0.1m to 7m
  • Horizontal GPS position accuracy: 3m CEP (circular error probable)
  • Operating temp range: -20°C to +50°C
  • Storage temp range: -20°C to 70°C
  • Environmental protection: IP54
  • Batteries: 2 x LR20 (D) 1.5V alkaline
  • Data interface: USB 2.0, Bluetooth Low Energy (Android & Apple)
  • Recommended service interval: 1 year
  • Warranty: 12 months from purchase
  • Data storage capacity: 4GB
  • Calibration warning: Countdown from 31 days before due
Genny4 Specifications
  • Signal output power: 0.1W
  • Signal boost output power: 1.0W
  • Induction mode signal characteristic: 33kHz
  • Direct connection/clamp signal characteristic: 33kHz and small diameter locate frequency. Automatic impedance matching on connection
  • Batteries: 4 x LR20 (D) 1.5V alkaline
  • Warranty: 12 months