Kane 9206 Quintox Industrial Flue Gas Analyser & Semi-Continuous Emissions Monitor

SKU: KANE9206
  • Intuitive 8 gas analyser with instant & long-term monitoring
  • CO 0-10,000ppm (H2 compensated) with autorange to 10%
  • Built-in Wireless connectivity & storage space for 64,000 results
  • Qualifies for KANE CARE after sales support
More Info
Typically ships in 2-5 working days

Kane 9206 Quintox Industrial Flue Gas Analyser & Semi-Continuous Emissions Monitor

The Kane 9206 Quintox Industrial FGA & Semi-Continuous Emissions Monitor is a unique 8 gas instrument, independently tested and incredibly versatile. This cost effective unit is customisable to meet specific requirements, using electro-chemical sensors to monitor Carbon Monoxide, Carbon Dioxide & Hydrocarbons or NO, NO2, SO2 & H2S when used in conjunction with additional sensors. Differential Pressure is measured via an internal Pitot flow calculation, other incorporated measurements include:

  • 02 0-25%
  • CO 0-10,000ppm (H2 Compensated) with autorange to 10%
  • Pressure 0-150 mbar
  • Efficiency 0-100%
  • Temperature 0-1100°C with optional probe

The main purge system of the Kane 9206 Quintox automatically protects the sensor from being over-ranged and refreshes the sensor during long term monitoring, all whilst allowing sensor zeroing without the need to withdraw the probe from the flue. This fully featured emissions analyser also encompasses an Active Flow Control which compensates for sample pressure fluctuation and filter blocking by adjusting the pump speed to maintain a set sample gas flow rate. This industrial flue gas analyser is compatible with the following fuel types.

  • Natural Gas
  • Butane
  • Propane
  • LPG
  • 28 sec oil
  • 35 sec oil
  • Wood pellets
  • User fuel
  • Heavy Oil

Through the large graphical display of the 9206 Quintox up to 15 lines of text or data can be displayed. An impressive internal memory can store up to 64,000 tests with each result GPS tagged allowing users to pinpoint exact test locations. Wireless & USB ports are built into the base unit for cable free connections and an incorporated printer features an additional output for optional portable IR printer, ideal when working away from the base unit. With user selectable languages, the Kane 9206 is MCERTS (pending) compatible with an optional 9206 sample conditioning unit and comes complete with a PTFE lined CHSP6 probe, heavy duty case and more.

Kane Live & Printer Apps

The Kane Live App is compatible with Android Devices and free from the Play Store. This multilingual App includes several extremely useful features beneficial for anyone with a Flue Gas Analyser. See your test results live on your smart device and even tag them with real-time GPS data & printouts all while still physically on site. Printouts can be shared along with downloaded analyser logs as CSV files, with analyser user details amendable within the App itself.

The Kane Printer App is compatible with Android/iOS and is free from both the Play & App Store. With this app users can quickly connect to their analyser and view test results before emailing them to their contacts. Log each test location via GPS then save printouts to edit before transfer. Fully customise personal notes even in poor lighting conditions as a useful NightMode is incorporated within the app.

Kane Care

This product qualifies for Kane Care after sales support, guaranteeing you a 10 year 'No Quibble' warranty for your annual service, same day service & recertification and free tracked, next day delivery to Kane with returns. For more information please visit Kane.co.uk.

Key Features

  • Industrial flue gas analyser
  • Semi-continuous emissions monitor
  • 8 gas instrument for instant and persistent monitoring
  • Built-in electro-chemical sensors
  • Monitor CO, CO2 & Hydrocarbons
  • Additional sensors for NO, NO2, SO2 & H2S
  • Measures differential pressure via Pitot flow calculation
  • Also measures 02 0-25% and CO 0-10,000ppm (H2 Compensated) with autorange to 10%
  • Pressure and efficiency measurements available
  • With optional probe measure temperature up to 0-1100°C
  • Main purge refreshes sensor and protects from overhang
  • Zero sensor without withdrawing from the flue
  • Active flow control incorporated
  • Compatible with wide array of fuel types
  • Large display with 15 lines of data
  • Internal memory holds 64,000 results
  • Results are GPS tagged
  • Built-in wireless capability
  • Compatible with Kane Apps
  • USB ports for PC connection
  • Incorporated printer with option for additional wireless printer
  • Customisable language settings
  • Kane 9206 is MCERTS (pending) compatible with optional 9206 sample conditioning unit
  • Supplied with a PTFE lined CHSP6 probe, heavy duty case and more

Kane part number: 9206

What's In The Box?

  • Kane 9206 Quintox - Industrial FGA & semi continuous Emissions Monitor
  • PTFE Lined CHSP6 Probe
  • Pressure Connectors
  • 19603 Charger
  • Quick Reference Guide
  • Heavy Duty Case
  • Analyser Calibration Certificate