Keller LEO Record Digital Manometer (31bar)
The Keller LEO Record Digital Manometer has a pressure measurement range of -1bar to 31bar with accuracy of ±0.1% FS and a resolution of 10mbar. It has an internal memory and takes readings via a G1/4” male connection, making it suitable for long-term monitoring of industrial processes.
The Keller LEO Record has a clear digital screen that shows pressure readings in a range of different units. It has a maximum display/measurement rate of once per second and is operated using just two buttons. The zero function allows relative measurement which negates the effects of variable barometric pressure.
Thanks to its large internal memory, the Keller LEO Record is suitable for long-term monitoring of industrial systems. It has room for up to 57,000 readings and can record both temperature and pressure. Event-controlled and interval recording help prevent unnecessary recording of data and it is also possible store installation data in the memory.
The Keller LEO Record has an RS485 Fischer connection which can be used to access the memory. To convert to a USB port, a Keller K114A cable adaptor is required. Keller Logger 5 software is provided as standard and this allows the user to configure the gauge, download data, and produce detailed reports.
The IP65 ingress protection rating on the Keller LEO Record means that it is suitable for use in tricky conditions and it has a two-year battery life.
Keller part number: 303025.0002
Key Features
- Absolute pressure range: -1bar to 31bar
- Accuracy: ±0.1% FS
- Resolution: 10mbar
- G ¼” male pressure connector
- Range of different units
- Memory for <57,000 readings
- Two-year battery life
- RS485 Fischer connector
- Keller Logger 5 software supplied
| |
ECO2 |
LEO1 |
LEO2 |
LEO3 |
LEO5 |
LEO Record |
LEX1 |
| -1 to 3bar |
|
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| -1 to 31bar |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| 0 to 100bar |
|
|
|
|
✔ |
|
|
| 0 to 300bar |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| 0 to 400bar |
|
|
|
|
|
|
✔ |
| 0 to 700bar |
|
✔ |
✔ |
✔ |
✔ |
✔ |
|
| 0 to 1000bar |
|
✔ |
|
✔ |
|
✔ |
✔ |
| Accuracy |
±0.5% FS |
±0.1% FS |
±0.1% FS |
±0.1% FS |
±0.05% FS |
±0.1% |
±0.05% FS |
Resolution (at smallest range) |
10mbar |
1mbar |
1mbar |
1mbar |
1mbar |
1mbar |
0.1mbar |
| Temperature range |
|
|
|
|
0˚C to 50˚C |
|
|
| Temperature accuracy |
|
|
|
|
±1˚C |
|
|
Intrinsically safe version |
✔ |
✔ |
✔ |
|
✔ |
✔ |
|
| Peak mode |
|
✔ |
|
|
✔ |
|
|
| Pressure connector |
7/16" UNF |
G 1/4" |
7/16" UNF |
G 1/4" |
G 1/4" |
G 1/4" |
G 1/4" |
| Analogue output |
|
|
|
✔ |
✔ |
|
|
| Internal memory |
|
|
|
|
✔ |
✔ |
✔ |
| Data port |
|
|
|
RS485 Binder |
USB |
RS485 Fischer |
RS485 Fischer |
Compatible with Keller-Bus protocol |
|
|
|
✔ |
✔ |
|
✔ |