Keller LEO Record Ei Intrinsically Safe Digital Manometer (700bar)
The Keller LEO Record Ei Intrinsically Safe Digital Manometer has a G ¼” male connector that allows it to take pressure readings from industrial systems. It has a range of 0 to 700bar with accuracy of ±0.1% FS and a resolution of 200mbar.
As an intrinsically safe manometer, the Keller Record Ei is suitable for measuring pressure in hazardous environments where there is a risk of combustion. It is classified as Ex II 2 G and Ex ia IIC T4 and has certification files PTB 05 ATEX 2012 X and IECEx PTB 13.0028X.
A number of different units are available on the Keller Record Ei and it has a digital display that clearly shows pressure readings. Min/max functionality captures extreme readings whilst a zero function enables relative measurements.
The large internal memory of the Keller LEO Record Ei makes it suitable for long-term pressure monitoring. It has an adjustable sample rate and can store up to 57,000 readings as well as offering both event-controlled and interval recording.
The Keller LEO Record Ei’s memory is accessed via the RS485 Fischer connection. In order to download results to a PC, an optional Keller K114A Cable Adaptor is required. For configuration of the manometer, data transfer, analysis and reporting, a Keller Logger 5 software package is provided as standard.
The Keller LEO Record Ei is suitable for challenging environments as it has an IP65 ingress protection rating and a battery life of up to two years.
Keller part number: 303025.2004
Key Features
- Intrinsically safe pressure gauge
- Measurement range: 0 to 700bar
- Accuracy: ±0.1% FS
- Resolution: 200mbar
- G ¼” male pressure connector
- Clear digital display
- Adjustable measurement rate
- Large internal memory
- RS485 Fischer connection
- Keller Logger 5 software
- Two-year battery life
| |
ECO2 |
LEO1 |
LEO2 |
LEO3 |
LEO5 |
LEO Record |
LEX1 |
| -1 to 3bar |
|
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| -1 to 31bar |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| 0 to 100bar |
|
|
|
|
✔ |
|
|
| 0 to 300bar |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
✔ |
| 0 to 400bar |
|
|
|
|
|
|
✔ |
| 0 to 700bar |
|
✔ |
✔ |
✔ |
✔ |
✔ |
|
| 0 to 1000bar |
|
✔ |
|
✔ |
|
✔ |
✔ |
| Accuracy |
±0.5% FS |
±0.1% FS |
±0.1% FS |
±0.1% FS |
±0.05% FS |
±0.1% |
±0.05% FS |
Resolution (at smallest range) |
10mbar |
1mbar |
1mbar |
1mbar |
1mbar |
1mbar |
0.1mbar |
| Temperature range |
|
|
|
|
0˚C to 50˚C |
|
|
| Temperature accuracy |
|
|
|
|
±1˚C |
|
|
Intrinsically safe version |
✔ |
✔ |
✔ |
|
✔ |
✔ |
|
| Peak mode |
|
✔ |
|
|
✔ |
|
|
| Pressure connector |
7/16" UNF |
G 1/4" |
7/16" UNF |
G 1/4" |
G 1/4" |
G 1/4" |
G 1/4" |
| Analogue output |
|
|
|
✔ |
✔ |
|
|
| Internal memory |
|
|
|
|
✔ |
✔ |
✔ |
| Data port |
|
|
|
RS485 Binder |
USB |
RS485 Fischer |
RS485 Fischer |
Compatible with Keller-Bus protocol |
|
|
|
✔ |
✔ |
|
✔ |