Kewtech EZYPAT PAT Test Kit C

SKU: KEWTEZYPATKITC
  • The most comprehensive kit for the Kewtech EZYPAT PAT Tester
  • Socket tester, microwave leakage detector, and PAT test labels
  • 110V adaptors for appliances and extension leads plus an IEC adaptor set
More Info
£550.80 £459.00
In Stock - Available Next Day

Kewtech EZYPAT PAT Test Kit C

Kewtech EZYPAT PAT Test Kit C is an ideal set for low-volume, in-house PAT testing regimes. It features the Kewtech EZYPAT PAT Tester which has automatic test sequences for Class I appliances, Class II appliances, and IEC/extension leads. Tests include earth bond testing, insulation resistance testing, polarity checking and substitute leakage measurement and the tester gives actual values plus a PASS/FAIL indication. It is operated using simple push buttons and is very user-friendly.

Several accessories are supplied in Kewtech EZYPAT Kit C. These include a range of adaptors (110V, 110V extension lead, IEC adaptor set), PAT labels (PASS, FAIL, PassWrap, Tuff Tag, microwave), and additional testing equipment (microwave leakage detector, socket tester). Furthermore, a Kewtech carry case, PAT certificate pad and PAT register book are also provided.

Kit Contents

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book
  Kit A Kit B Kit C
Kewtech EZYPAT PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT register book x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector  
Microwave emission labels  
Kewtech KITBAG2 carry case  

What's In The Box?

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book
Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)

Please see our terms and conditions for full details of TM Care & Protect.

Everything you’re likely to require for the next 3 or 5 years:

✅ Annual calibrations included
No further calibration costs for either 3 or 5 years

✅ Free collection and return for annual calibration
No hidden postage costs when it’s time for calibration

✅ ‘Zero-Downtime’ for the life of your care plan
Free loan equipment should your purchase ever need sending away for repair

✅ Anti-theft protection 
Each care plan includes a SmartTrace Forensic Marking kit that acts as a deterrent for your test equipment and other tools

✅ Instrument cleaning kit
Cleaning kit included with each TM Care & Protect plan

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Ensures complete reliability, minimised downtime and peace of mind. TM Care & Protect packages include:

✅ Annual Calibration
No further calibration costs for up to 5 years.

✅ Zero Unplanned Downtime
In case of any unforeseen repairs, we provide FREE loan instruments so you can continue working.

✅ Theft Deterrent Kit
Each care plan includes a SmartTrace forensic marking kit: The UK's most powerful theft deterrent. Use on your test equipment, van and tools.

✅ No Shipping Cost
Includes collection and return deliveries when it's time for calibration.

✅ Instrument Cleaning Kit
Avoid preventable issues by keeping your test equipment clean.

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Please see our terms and conditions for full details of TM Care & Protect.