Megger DET4TC2 Earth Tester with ETK50C Earth Spike Cable Set and Clamps

SKU: MEGGER1012521
  • Complete DET4TC2 and ETK50C earth testing kit with tester, clamps, cable reels, earth spikes and accessories included
  • Supports 2-pole, 3-pole, 4-pole, ART and stakeless testing for flexible earth resistance testing
  • Field-ready design with IP54 protection, selectable test frequencies and simple one-button operation
More Info
£2,398.80 £1,999.00
In Stock - Available Next Day

Megger DET4TC2 Earth Tester with ETK50C Earth Spike Cable Set and Clamps

The Megger DET4TC2 Earth Tester with ETK50C Earth Spike Cable Set and Clamps is a comprehensive earth testing kit designed for earth resistance and soil resistivity testing. Combining the Megger DET4TC2 four-terminal earth tester with the ETK50C 50m cable reel kit, this package provides the instrument, clamps, test leads, spikes and accessories needed for professional earth electrode testing in one complete solution.

The Megger DET4TC2 is a dry-cell battery-powered four-terminal earth tester designed for demanding ground testing applications. It supports 2-pole, 3-pole and 4-pole resistance testing, as well as Attached Rod Technique testing, stakeless testing, leakage current measurement and earth noise voltage measurement when used with the appropriate clamps.

For improved flexibility in the field, the DET4TC2 allows users to select from four test frequencies: 94Hz, 105Hz, 111Hz and 128Hz. This helps reduce the effect of interference in electrically noisy environments. The instrument also features selectable 25V or 50V output voltage, automatic C stake, P stake and noise checks, a backlit display and simple one-button operation.

The included ETK50C Earth Spike Cable Set and Clamps expands the kit for practical field testing. It includes 50m red and yellow test leads, 30m black and green test leads, four earth test spikes, interconnection leads, MCC1010 and MVC1010 clamps, test leads, a 100m measuring tape and a holdall for transportation. The reels are designed to be easy to wind and unwind, helping users set up and pack away efficiently during earth electrode testing and soil resistivity surveys.

Key Features

  • Complete earth testing kit with DET4TC2 tester and ETK50C cable/clamp set
  • Suitable for earth resistance and soil resistivity testing
  • Supports 2-pole, 3-pole and 4-pole testing
  • Attached Rod Technique and stakeless testing with supplied clamps
  • Selectable 25V or 50V output voltage
  • Four selectable test frequencies to help reduce interference
  • Measures earth noise voltage and leakage current
  • Automatic stake and noise checks
  • Backlit display with simple one-button operation
  • IP54 rated and CAT IV 100V safety rated
  • ETK50C includes cable reels, earth spikes, clamps, measuring tape and holdall

What's In The Box?

Megger Digital Ground Tester & Clamps Kit

  • Megger DET4TC2 Earth Tester
  • Standard stake and wire kit (15m, 10m, 10m, 3m)
  • ICLAMP for ART testing
  • VCLAMP for stake-less testing
  • Right angle terminal adaptors
  • Field calibration check for instrument and clamps
  • Hard carry case
  • External AC/DC charger (w/ rechargeable)

ETK50C Earth Spike 50m Cable and Clamp Kit

  • 50m red test lead on reel
  • 50m yellow test lead on reel
  • 30m black test lead on reel
  • 30m green test lead on reel
  • 4 x earth test spikes
  • Red interconnection lead
  • Yellow interconnection lead
  • Black interconnection lead
  • Green interconnection lead
  • Megger MCC1010 Current Clamp
  • Megger MCC1010 test lead
  • Megger MVC1010 Voltage Clamp
  • Megger MVC test lead
  • 2 x 1.4m leads with connectors and clips
  • 100m measuring tape
  • Holdall to contain kit
Specification

    General

  • Ingress protection: IP54
  • C stake, P stake and Noise check: Automatic
  • Noise rejection: 40 V pk to pk
  • 2-wire, 3-wire, 4-wire test: Yes, no shorting links required
  • No disconnect testing (ART): Yes, with ICLAMP
  • Stakeless measurement: Yes, with ICLAMP and VCLAMP
  • Display: 3.5” digit high contrast liquid crystal, backlit
  • Battery type: DET4TC2: 8 off AA (LR6) cells
  • Operating temperature range: -15 °C to +55 °C / 5 °F to 131 °F
  • Storage temperature range: -40 °C to +70 °C / -40 °F to 158 °F

Instrument output

  • Voltage: ±25 V or ±50 V at 94 Hz, 105 Hz, 111 Hz and 128 Hz
  • Current: 4.5 mA or 0.45 mA or 0.045 mA
  • Ground current range with clamp: 0.5 mA to 19.9 A
  • Ground current accuracy: 5% ±3 digits
  • Ground voltage range: 0 to 100 V ac
  • Ground voltage accuracy: 2% ±2 V

Resistance ranges

  • 2, 3, 4 pole: 0.01 Ω to 200 kΩ
  • ART: 0.01 Ω to 200 kΩ
  • Stakeless: 0.01 Ω to 200 Ω

Resistance accuracy

  • 2P measurements: 2% ±3 digits
  • 3P measurements: 2% ±3 digits
  • 4P measurements: 2% ±3 digits
  • ART measurements: 5% ±3 digits
  • Stakeless measurements: 7% ±3 digits

Maximum probe resistance

  • Rp limit: 200 kΩ (50 V output voltage)
  • Rc limit: 200 kΩ (50 V output voltage)
  • Limits reduced to 100 kΩ for 25 V output voltage
  • Limits reduced to 5 kΩ for 0.01 Ω resolution

Safety

  • Complies with the requirements of IEC61010-1 100V CAT IV between terminal pairs.*

EMC

  • In accordance with IEC61326-1

Standards Compliance

  • Complies with the requirements of KEMA K85B
  • Complies with the following parts of EN61557, “Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures”.
  • Part 1 - General requirements
  • Part 5 - Resistance to earth
  • Dimensions: 203 mm x 148 mm x 78 mm (8 in x 5.8 in x 3 in)
  • Weight: 1kg (2.2lb)

*The CAT IV 100 V rating is dependant on the use of a lead set of
at least this rating, for example the optional two wire lead set part
number 1001-858.