Megger EGIL Circuit Breaker Analyser

SKU: MEGGEGIL
  • Designed for breakers with one main contact per phase
  • Measures timing, coil current, and IEC-standard parameters
  • Easy to use with built-in control, printer, and optional PC software
More Info
Price Available Upon Request
Made to order

Megger EGIL Circuit Breaker Analyser

The Megger EGIL Circuit Breaker Analyser is a compact and affordable instrument designed specifically for testing breakers with one main contact per phase. Despite its smaller size, it incorporates many of the features found in larger, more complex systems, making it the ideal choice for use in smaller power plants or as a supplementary tool for maintenance teams in larger utilities. EGIL features three timing channels with a common ground, allowing simultaneous measurement of main contacts, including those with pre-insertion resistors. It also includes two separate channels for auxiliary contact timing. Coil currents are measured automatically and displayed instantly on the built-in screen or printed via the integraed thermal printer. To simplify setup, the system comes with pre-wired multi-cable sets for both main and auxiliary contacts. A built-in control unit prepares the instrument for the next breaker operation, streamlining the testing process.

The Megger EGIL is available as one of several options, with the user able to choose between a standalone product, or a choice of USB port, software, and accessories. To see what these kits comprise of, look at the ‘What’s in the Box?’ section at the bottom of this page, and if you have any questions about this or wish to enquire about a specific configuration, do not hesitate to get in touch with our team who will be happy to assist you in finding the right choice for you.

EGIL is designed for testing high-voltage circuit breakers with a single break per phase, typically at medium voltage levels. It records contact timings for main, pre-insertion resistor, and auxiliary contacts, as well as coil currents. The system also calculates key parameters based on IEC standards, such as opening and closing times, phase differences, over-travel, and CO/OC times, which are included in the test report.

To arrange a demo for this product, simply click the ‘Arrange a Demo’ button at the top of the page, and to find out more about this product and the options that are available, do not hesitate to contact our team.

Key Features

  • Designed for high-voltage circuit breakers with one main contact per phase
  • Compact and cost-effective, ideal for smaller substations and maintenance teams
  • Measures timing of main, auxiliary, and pre-insertion resistor contacts
  • Records coil currents automatically and displays results instantly
  • Three main timing channels share a common ground for easy connection
  • Two dedicated channels provided for auxiliary contact timing
  • Built-in breaker control unit automatically sets up the next operation
  • Integrated thermal printer outputs test results on-site
  • Supplied with pre-made multi-cable set for quick and simple setup
  • Calculates opening/closing times, over-travel, phase differences, CO/OC times (IEC standard)
  • Stores and prints detailed test reports for traceability
  • Ideal as a primary unit for small plants or a supplementary tool in larger utilities
  • multiple kit options are available to suit individual needs

What's In The Box?

EGIL Basic Unit (BM-19090)

  • Cables timing measurement (GA-00160, GA-00170)
  • Extension cable timing (GA-00150)
  • Cable set for breaker control unit (GA-00082)
  • Transport case (GD-00195)

EGIL with USB port (BM-19092)

  • CABA Win software (BL-8206X)
  • Cables timing measurement (GA-00160, GA-00170)
  • Extension cable timing (GA-00150)
  • Cable set for breaker control unit (GA-00082)
  • Transport case (GD-00195)

EGIL with analogue input channel and USB port (BM-19093)

  • CABA Win software (BL-8206X)
  • Cables timing measurement (GA-00160, GA-00170)
  • Extension cable timing (GA-00150)
  • Cable set for breaker control unit (GA-00082)
  • Transducer cable XLR-open (GA-00041)
  • Transducer cable XLR-XLR (GA-00042)
  • Transport case (GD-00195)

EGIL with SDRM option and USB port (BM-19095)

  • CABA Win software (BL-8206X)
  • Cables timing measurement (GA-00160, GA-00170)
  • Extension cable timing (GA-00150)
  • Cable set for breaker control unit (GA-00082)
  • Transducer cable XLR-open (GA-00041)
  • Transducer cable XLR-XLR (GA-00042)
  • Transport case (GD-00195)
Specification
  • Power Supply – Swappable 115V/230V AC, 50/60Hz
  • Measurement Channels – 3 timing channels (common ground) plus 2 isolated auxiliary timing channels
  • Timing Resolution – Adjustable between 0.1ms and 10ms; time span range from 1s to 100s
  • Timing Accuracy - ±0.05% of reading ± resolution
  • Current Measurement - ±25 A range, resolution 25 mA, accuracy ±1% of reading ±100 mA
  • Open-Circuit Voltage - 24 V ±20%
  • Auxiliary Contact Sensing - Dry contact thresholds: Closed <600 Ω ±30%; Open >600 Ω ±30% at 20 V ±20%; Short-circuit current 25 mA ±20%
  • Static Resistance Testing - Requires optional SDRM201 module for dynamic resistance measurement (DRM) and micro‑ohm checks
  • Outputs & Controls – Includes built-in breaker control for automatic sequenced testing, pre-insertion resistor detection, and coil current capture
  • Display & Printing – LED display with built-in thermal printer (203dpi, 114mm width) for graphical and numeric test results
  • Safety & Environment Ratings - Operating temperature: -10°C to +50°C; storage: -40°C to +70°C; humidity 5‑95% RH non-condensing
  • Dimensions & Weight – Unit: 360 x 210 x 190mm; with accessories case: 420 x 300 x 230mm; Weight: 6.3kg (14lbs), 10kg (22lbs) with accessories
  • Regulatory Compliance – CE marked to LVD (2006/95/EC) and EMC (2004/108/EC) standards
For extensive specifications, view the attached datasheet.
Label Type Size Download