Megger TXL865 Extended Battery Load Unit

SKU: MEGGTORKELTXL865

Never Beaten On Price

 

We’re always working hard to give you the best possible price, but if you find it cheaper somewhere else, we’ll endeavour to match the price.

 

Call 0113 248 9966 or contact us online

Made to order
Recommended Add-ons
Need Some Help From Our Experts? chevron-right chevron-down

We're always happy to offer help, information & advice to find the right instrument for you, so please get in touch.

 

To speak to our sales team, call us on 0113 248 9966, use our Live Chat service or contact us online.

Members earn 8100 reward points chevron-right chevron-down

Use reward points to get money off future purchases.

 

Please note: Customers must be signed into their account to be elegible. Find out more about reward points here.

FREE Delivery & 60 Day Returns chevron-right chevron-down

We offer FREE standard delivery on all orders over £249, with a range of next-day options also available on many items.

 

Find out more on our delivery information page.

Key Features
  • Extra load unit for increasing the discharge capacity of Megger TORKEL battery test systems
  • Maximum load capacity of 25.5kW with up to 117A current
  • Suitable for battery systems up to 260V DC

Related Categories

Megger TXL865 Extended Battery Load Unit

Please note: There are two versions of the Megger TXL865 unit available, both with or without accessories. If ordered with accessories, the unit is supplied with a cable set, control cables, and a flight case, allowing for simple transport. Please select your preferred option when ordering this product.

The Megger TXL865 Multi-Battery Extra Load Unit is designed for use alongside Megger TORKEL battery discharge test systems, providing additional load capacity when higher discharge currents are required. By connecting the TXL865 directly to the battery under test, users can extend the capabilities of a TORKEL system for testing larger industrial battery banks.

The TXL865 supports battery systems up to 260V DC and provides a maximum current of 117A, with a maximum load power of 25.5kW. Multiple TXL units can also be used alongside a TORKEL to create a battery discharge system capable of handling currents of several kiloamps, making the unit particularly suitable for demanding stationary battery applications.

During testing, the TORKEL controls the discharge process and monitors the total battery current using an external clamp-on current probe. The TXL865 itself comprises a resistive load and works under control of the TORKEL, allowing constant-current or constant-power battery capacity tests to be carried out at higher load levels.

Designed for use in substations, industrial facilities, UPS installations and other environments containing large standby battery systems, the TXL865 provides a practical means of increasing the load capacity of an existing Megger TORKEL battery testing setup.

Megger TXL Series Comparison Table

Model Maximum DC Voltage Maximum Current Maximum Power
TXL830 28V DC 300A 8.3kW
TXL850 56V DC 300A 16.4kW
TXL865 260V DC 117A 25.5kW
TXL870 280V DC 112A 15.8kW
TXL890 480V DC 62A 15.4kW

What's In The Box?

  • Megger TXL865 Extra Load Unit
  • Battery cable set
  • 2 x 2m control cables
  • Transport case
Show Trustpilot Reviews
Specification
Yes
  • Maximum DC voltage - 260V DC
  • Maximum current - 117A
  • Maximum current at 260V - 98A
  • Maximum power - 25.5kW
  • Internal resistance – Position 1 - 2.65Ω
  • Internal resistance – Position 2 - 5.05Ω
  • Internal resistance – Position 3 - 0.12Ω
  • Mains supply - 100–240V AC, 50/60Hz
  • Power consumption - 75W max.
  • Protection - Thermal cut-outs and automatic overload protection
  • Operating temperature - 0°C to +40°C
  • Storage temperature - -40°C to +70°C
  • Humidity - 5%–95% RH, non-condensing