Metrel MI3360 OmegaPAT XA PAT Tester

SKU: METRMI3360-CONF
  • Incredibly comprehensive PAT tester with multiple RCD testing options
  • Large internal memory for user accounts and multi-layered structure, software provided
  • Purchase options for three-phase, arc-weld and medical equipment testing
More Info
Choose Your Free Gift

Metrel MI3360 OmegaPAT XA PAT Tester

The Metrel MI3360 OmegaPAT XA PAT Tester is the ideal solution for comprehensive PAT testing over the domestic, commercial and industrial sectors thanks to its advanced range of powerful and speedy testing functions, innovative memory and automatic test sequences. It tests at both 110V (optional adaptor required) and 230V and is capable of all basic PAT testing functions plus flash testing (‘F’ model only) and further advanced testing optionsIncluding measurement of an appliance’s consumption, leakage and power with just one step.

Portable and regular RCD testing (A, AC, B, B+, F type) is another feature of the Metrel MI3360. Standard test currents are 10mA, 15mA and 30mA. Automatic and manual RCD testing are available and the tester can even verify advanced P-RCDs (3-pole, K/Di {varistor}, S type) used in challenging conditions and environments where quick intervention is required.

Aside from PAT testing, the Metrel MI3360 can be used to test three-phase appliances for power, leakage and polarity as well as testing appliances’ RCDs. An A1322 or A1422 three-phase adaptor is required for three-phase testing and these also increase the RCD testing current to 100mA or 300mA as required.

Additionally, the Metrel A1422 works in conjunction with the MI3360 in order to test arc/welding equipment by performing primary welding leakage, welding leakage, welding insulation and no load voltage testing in compliance with IEC/EN 60974-4.

Medical appliance testing is a further useful option on the Metrel MI3360 when purchased as the ‘M’ model. It is fully compliant with IEC/EN 62353 with special functions including electrical equipment leakage, applied part leakage and touch leakage testing.

Further to its testing capabilities, the Metrel MI3360 is an outstanding instrument because of its pre-set and customisable automatic testing sequences which are facilitated by Metrel Electrical Safety Manager Software. Alongside test sequences, the large internal memory on the Metrel MI3360 allows the creation of several password-protected user accounts (ideal for traceability) in addition to a multi-layer structure that can save anything from a client name and location right down to multiple details of individual appliances in individual projects.

Please use the options above to select which version of the tester you require (standard, ‘25A’, ‘M’ or ‘F’) and to add the A1322 or A1422 adaptor according to your requirements. Standard accessories include test leads, cables, probes, crocodile clips, software and a manufacturer’s calibration certificate. Overall, the Metrel MI3360 constitutes a fast, sophisticated PAT tester with multiple uses across a wide range of industries.

Metrel part number: MI3360

Key features

  • 110V and 230V appliance testing
  • Earth bond testing (25A test current with ‘25A’, ‘M’ and ‘F’ models)
  • Insulation testing
  • Leakage testing
  • Functional test
  • Flash testing (‘F’ model only)
  • P-RCD and RCD testing
  • Three-phase appliance testing (with adaptor)
  • Arc/welding equipment testing (with A1422 adaptor)
  • Medical equipment testing (‘M’ model only)
  • Pre-set and custom auto test sequences 
  • Fast testing procedure
  • Traceable user accounts
  • Large, multi-layered memory
  Standard (S) High Current (25A) Medical (M) Flash (F)
Visual Inspections
Fuse Test
Continuity / Earth Bond Resistance 200mA
Continuity / Earth Bond Resistance 10A & 25A  
Insulation Resistance (Riso, Riso-S)
Substitute Leakage Current
Differential Leakage Current
PE Leakage Current
Touch Leakage Current
Polarity / Active Polarity
Power (P, S, Q, PF, THDu, THDi, Cosø, I, U)
P-RCD, (2 pole, 3 pole, K/ Di (varistor), S (3-pole))
PRCD PE probe test, open conductor test, PE conductor test
RCD test, (type A, AC, B, B+, F)
Flash test (1500V, 3000V)      
Insulation Resistance, IEC/EN 62353      
Touch Leakage Current, IEC/EN 62353      
Equipment Leakage (Direct, Differential, Alternative), IEC/EN 62353      
Applied Part Leakage (Direct, Alternative), IEC/EN 62353      
Insulation resistance, (optional A 1422) IEC/EN 60974-4
Welding circuit leakage, (optional A 1422) IEC/EN 60974-4
Primary leakage, (optional A 1422) IEC/EN 60974-4
No-load voltage, (optional A 1422) IEC/EN 60974-4

What's In The Box?

  • Metrel MI3360 OmegaPAT XA PAT Tester
  • Bag for accessories
  • Smartball pen with touch screen function
  • Flash test probe (MI 3360 F only)
  • Crocodile clip, red (MI 3360 F only)
  • IEC test cable, 2 m
  • Test lead, black
  • Test tip, black
  • Alligator clip, black
  • Mains cable
  • USB cable
  • Calibration Certificate
  • Short form instruction manual
  • CD with instruction manual (full version) and PC SW Metrel ES Manager
Specification

Continuity // Protective earth resistance

Continuity

  • Ranges: 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω 
  • Resolution: 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω
  • Accuracy: ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative
  • Operating range (acc. to EN 61557-4)............. 0.08 Ω … 199.9 Ω
  • Test currents..................................................... 0.2 A,10 A, 25 A
  • Current source (at nominal mains voltage, use of standard accessories)
  • .......................................................................... > 0.2 A at R < 2 Ω
  • .......................................................................... > 10 A at R < 0.1 Ω at 230 V
  • .......................................................................... > 25 A into short circuit at 230 V
  • Open circuit voltage.......................................... < 9 V a.c.

Test terminals:

Continuity

  • R (200 mA): P/S – PE, Socket PE; Socket PE – IEC PE
  • R (10 A, 25 A): P/S – Socket PE; Socket PE – IEC PE

Protective earth resistance

  • R (200 mA): P/AP – PE, Socket PE
  • R (10 A, 25 A): P/AP – Socket PE

Insulation Resistance (Riso, Riso-S)

  • Insulation resistance, Insulation resistance –S (250 V, 500 V)
  • Range: 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ 
  • Resolution: 0.01 MΩ / 0.1 MΩ / 0.1 MΩ 
  • Accuracy: ±(3 % of reading + 2 D) / ± 5 % of reading /± 10 % of reading

Output voltage (Um)

  • Range: 0 V … 600 V 
  • Resolution: 1V 
  • Accuracy: ±(3 % of reading + 2 D)
  • Operating range (acc. to EN 61557-2).........0.08 MΩ … 199.9 (999) MΩ
  • Nominal voltages Un ....................................250 V, 500 V (- 0 %, + 10 %)
  • Short circuit current ......................................max. 2.0 mA

Test terminals:

  • Riso LN, Socket LN – PE, Socket PE, P/S
  • Riso-S LN, Socket LN – P/S

Sub-Leakage Current, Substitute Leakage Current - S (Isub, Isub-S)

  • Range: 0.00 mA … 1.99 mA / 2.00 mA … 19.99 mA 
  • Resolution: 0.01mA / 0.01mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)
  • Operating range (acc. to EN 61557-16)........... 0.02 mA … 19.99 mA
  • Open circuit voltage.......................................... 230 V a.c., 110 V a.c.
  • Current calculated to mains supply voltage (110 V or 230 V) is displayed.

Test terminals:

  • Isub LN, Socket LN – PE, Socket PE, P/S
  • Isub-S LN, Socket LN – P/S


Differential leakage current (Idiff)

Differential leakage current

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1 µA / 0.01 mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Power (active) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA
  • Influence of load current................................... < 0.02 mA/A

Test terminals:

  • Idiff Socket L,N – Socket PE, P/S
  • P Socket L – Socket N

PE leakage current (Ipe)

PE leakage current

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1µA / 0.01mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Power (active) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA

Test terminals:

  • Ipe Socket L,N – Socket PE
  • P Socket L – Socket N

Touch leakage current (Ipe)

Touch leakage current

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA
  • Resolution: 1 µA / 0.01mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Power (active) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA

Test terminals:

  • Itou: Socket L,N – P/S
  • P: Socket L – Socket N

Power

Power (active) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Power (apparent) (S)

  • Range: 0 VA … 999 VA / 1.00 kVA … 3.70 kVA 
  • Resolution: 1 VA / 10VA 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Power (reactive) (Q)

  • Range: ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr 
  • Resolution: 1 VAr / 10 VAr
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Power factor (PF)

  • Range 0.00i … 1.00i / 0.00c … 1.00c 
  • Resolution: 0.01 
  • Accuracy: ±(5 % of reading + 5 D)

Total Harmonic Distortion (voltage) (THDU)

  • Range: 0.0 % … 99.9 % 
  • Resolution: 0.1 % 
  • Accuracy: ±(5 % of reading + 5 D)

Total Harmonic Distortion (current) (THDI)

  • Range: 0.00 A … 16.00 A 
  • Resolution: 0.01 A 
  • Accuracy: ±(3 % of reading + 5 D)

Cosinus Φ (Cos Φ)

  • Range: 0.00i … 1.00i / 0.00c … 1.00c 
  • Resolution: 0.01 
  • Accuracy: ±(5 % of reading + 5 D)

Current (I)

  • Range: 0.00 A … 16.00 A 
  • Resolution: 0.01 A 
  • Accuracy: ±(3 % of reading + 5 D)

Voltage (U)

  • Range: 0.0 V … 199.9 V / 200 V … 264 V 
  • Resolution: 0.1V / 1V 
  • Accuracy: ±(3 % of reading + 10 D) / ±3 % of reading

Test terminals:

  • P,S,Q,PF,THDU,THDI, Cos Φ, I, U: Socket L – Socket N

Leaks & Power

Power (active) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Touch leakage current: (Itou)

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA
  • Resolution: 1 µA / 0.01 mA
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA

Differential leakage current (Idiff)

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1 µA / 0.01 mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA
  • Influence of load current................................... < 0.02 mA/A

Power (apparent) (S)

  • Range: 0 VA … 999 VA / 1.00 kVA … 3.70 kVA 
  • Resolution: 1 VA / 10VA 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Power (reactive) (Q)

  • Range: ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr 
  • Resolution: 1 VAr / 10 VAr
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading

Power factor (PF)

  • Range 0.00i … 1.00i / 0.00c … 1.00c 
  • Resolution: 0.01 
  • Accuracy: ±(5 % of reading + 5 D)

Total Harmonic Distortion (voltage) (THDU)

  • Range: 0.0 % … 99.9 % 
  • Resolution: 0.1 % 
  • Accuracy: ±(5 % of reading + 5 D)

Total Harmonic Distortion (current) (THDI)

  • Range: 0.00 A … 16.00 A 
  • Resolution: 0.01 A 
  • Accuracy: ±(3 % of reading + 5 D)

Cosinus Φ (Cos Φ)

  • Range: 0.00i … 1.00i / 0.00c … 1.00c 
  • Resolution: 0.01 
  • Accuracy: ±(5 % of reading + 5 D)

Current (I)

  • Range: 0.00 A … 16.00 A 
  • Resolution: 0.01 A 
  • Accuracy: ±(3 % of reading + 5 D)

Voltage (U)

  • Range: 0.0 V … 199.9 V / 200 V … 264 V 
  • Resolution: 0.1V / 1V 
  • Accuracy: ±(3 % of reading + 10 D) / ±3 % of reading

Test terminals:

  • P,S,Q,PF,THDU,THDI, Cos Φ, I, U: Socket L – Socket N 
  • Idiff: Socket L,N – Socket PE, P/S
  • Itou: Socket L,N – P/S

PRCD test

Trip-out time (tΔN)

  • Range: 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N)
  • Resolution: 1ms / 1ms / 1ms 
  • Accuracy: ±3ms / ±3ms / ±3ms

*According to standard AS/NZS 3017

  • Trip out-current (IΔ)
  • Range: 0.2xI∆N … 2.2xI∆N 
  • Resolution: 0.05xI∆N 
  • Accuracy: ±0.1xI∆N
  • Test current type:.................sine-wave (AC), pulsed (A,F), smooth DC (B,B+)
  • Test currents (IΔN): .............10 mA, 15 mA, 30 mA;.................100 mA and 300 mA with A1322, A1422
  • Test current size (PRCD standard is AS/NZS 3017)............... ±5%
  • Test current size (general)………………-0/+10%

Test terminals:

  • tΔN, IΔ Socket – IEC

RCD Test

Trip-out time (tΔN)

  • Range: 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N)
  • Resolution: 1ms / 1ms / 1ms 
  • Accuracy: ±3ms / ±3ms / ±3ms

*According to standard AS/NZS 3017

Trip out-current (IΔ)

  • Range: 0.2xI∆N … 2.2xI∆N 
  • Resolution: 0.05xI∆N 
  • Accuracy: ±0.1xI∆N

Contact voltage (Uc)

  • Range: 0.0 V … 19.9 V / 20.0 V … 99.9 V 
  • Resolution: 0.1V / 0.1V 
  • Accuracy: (-0 % / +15 %) of reading ± 10 D / 0.1 V (-0 % / +15 %) of reading
  • Test current type:.................sine-wave (AC), pulsed (A,F), smooth DC (B,B+)
  • Test currents (IΔN): .............10 mA, 15 mA, 30 mA
  • Test current size (RCD standard is AS/NZS AS/NZS)...............  5%
  • Test current size (EN 61008/EN 61009)………………-0/+10%

Test terminals:

  • tΔN, IΔ Mains Socket

PE conductor (PRCD)

PE conductor (Type = 2 pole, 3 pole, S(3 pole)) (R)

  • Range: 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω 
  • Resolution: 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω 
  • Accuracy: ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative
  • Operating range (acc. to EN 61557-4)............. 0.08 Ω … 199.9 Ω
  • Current source (at nominal mains voltage, use of standard accessories).......................................................................... ..> 0.2 A at R < 2 Ω
  • Open circuit voltage.......................................... ..< 9 V a.c.

Test terminals:

  • R Socket PE – IEC PE

PE conductor (Type = K/ Di (varistor))

Test principle: A voltage is applied between PE connections of the PRCD-K. There is a ‘PASS’ if PRCD trips.

  • Open circuit voltage..................... 24 V
  • Output resistance......................... 220 Ω ± 10 % (IΔN = 30 mA), 620 Ω ± 10 % ((IΔN = 10 mA)

Test terminals:

  • Result: Socket – IEC

Open conductor (PRCD)

Test principle: Mains voltage is applied to the mains test socket. Disconnection of the L, N and PE connections is performed inside the instrument. There is a ‘PASS’ if the PRCD trips.

Test terminals:

  • L open, N open, PE open Socket – IEC


PRCD PE probe test

Test principle: Mains voltage is applied to the mains test socket. A safe voltage sufficiently high to activate the protection circuit in the PRCD is applied to the P/S terminal.

  • Test voltage (active) ......................................... > 100 V a.c.
  • Maximal current ................................................ < 1 mA

Test terminals:

  • Result (manual): Socket, P/S
  • Result (auto): Socket – IEC, P/S

Polarity

  • Test voltage (normal).................................................................. < 50 V
  • Test voltage (active)…………………………………………......... mains voltage
  • Power consumption of tested device during the active test…….< 25 VA

Test terminals:

  • Result (normal, active) Socket – IEC


Clamp current (I, Idiff, Ipe)

True RMS current using 1000:1 current clamp

  • Range: 0.10 mA … 9.99 mA / 10.0 mA … 99.9 mA / 100 mA … 999 mA / 1.00 A … 9.99 A / 10.0 A … 24.9 A 
  • Resolution: 0.01 mA / 0.1 mA / 1 mA / 0.01 A / 0.1 A 
  • Accuracy: ±(5 % of reading + 10 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits)

Accuracy of current transformer is not considered.
Frequency range of current clamp is not considered.

Test terminals:

  • I, Idiff, Ipe: CLAMPS terminals

Flash test

Current a.c. (apparent) (I)

  • Range: 0.00 mA … 2.50 mA 
  • Resolution: 0.01mA 
  • Accuracy: ±(5 % of reading + 5 D)
  • Open circuit test voltage..................... 1500 V, 3000 V (-0/+5%) at supply voltage 115 V, 230 V
  • Short circuit current…………………….< 3.5 mA
  • Output resistance: .................. ........... 480 kΩ@1500 V, 960 kΩ@3000 V

Test terminals:

  • I (1500 V): Socket LN – Socket PE
  • I (3000 V): Socket LN – FLASH

Insulation resistance Riso (welding equipment)

Riso

  • Range: 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ 
  • Resolution: 0.01 MΩ / 0.1 MΩ / 0.1 MΩ
  • Accuracy: ±(3 % of reading + 2 D) / ±5 % of reading / ±10 % of reading

Output voltage (Um)

  • Range: 0 V … 600 V 
  • Resolution: 1 V 
  • Accuracy: ±(3 % of reading + 2 D)
  • Operating range (acc. to EN 61557-2).........0.08 MΩ … 199.9 (999) MΩ
  • Nominal voltages Un ....................................500 V (- 0 %, + 10 %)
  • Short circuit current ......................................max. 2.0 mA

Test terminals:

  • Riso LN-W: A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – W1 W2
  • Riso W-PE: A 1422: Socket PE (16A-5p, 32A-5p or 16A-3p) – W1 W2
  • Riso LN-PE: A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – Socket PE (16A-5p, 32A-5p or 16A-3p)
  • Riso LN (Class II) - P: A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – MI 3360: P/S


Insulation Resistance (medical equipment)

Riso

  • Range: 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 199.9 MΩ
  • Resolution: 0.01 MΩ / 0.1 MΩ 
  • Accuracy: ±(3 % of reading + 2 D) / ±5 % of reading

Output voltage (Um)

  • Range: 0 V … 600 V 
  • Resolution: 1 V 
  • Accuracy: ±(3 % of reading + 2 D)
  • Operating range (acc. to EN 61557-2).........0.08 M … 199.9 (999) M
  • Nominal voltages Un ....................................500 V (- 0 %, + 10 %)
  • Short circuit current ......................................max. 2.0 mA

Test terminals:

  • Riso (LN-PE) LN, Socket LN – PE, Socket PE
  • Riso (LN-P/S) LN, Socket LN – P/S
  • Riso (LN-AP) LN, Socket LN – P/AP
  • Riso (PE-AP) PE, Socket PE – P/AP


Equipment leakage

Equipment leakage current (direct, differential, alternative) (Ieq)

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1 µA / 0.01 mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Ulpe (direct, differential, alternative)

  • Range: 0 V … 299 V 
  • Resolution: 1 V 
  • Accuracy: ±(2 % of reading + 2 D)

Power (direct, differential) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1W / 10W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading
  • Operating range direct and differential method (acc. to EN 61557-16)…..0.010 mA … 19.99 mA
  • Operating range alternative method (acc. to EN 61557-16)……………….0.020 mA … 19.99 mA
  • Influence of load current (differential method) . …………….< 0.02 mA/A

Test terminals:

  • Ieq (alternative): LN, Socket LN – PE, Socket PE, P/S, P/AP
  • Ieq (direct, differential): Socket L,N – PE, Socket PE, P/S, P/AP
  • Ulpe: Socket L – Socket PE
  • P (direct, differential): Socket L – Socket N


Applied Part leakage

Applied Part leakage current (direct, alternative) (Iap)

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1 µA / 0.01 mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Uap (direct, alternative)

  • Range: 0 V … 299 V 
  • Resolution: 1 V 
  • Accuracy: ±(2 % of reading + 2 D)

Power (direct (P))

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW
  • Resolution: 1 W / 10 W 
  • Accuracy: ±(5 % of reading + 5 D) / ±5 % of reading
  • Operating range direct method (acc. to EN 61557-16)…………0.010 mA … 19.99 mA
  • Operating range alternative method (acc. to EN 61557-16)……0.020 mA … 19.99 mA

Test terminals:

  • Iap (alternative): Socket LNPE, PE – P/AP
  • Iap (direct): Socket L,N,PE, PE – P/AP
  • Uap: Socket PE, PE – P/AP
  • P: Socket L – Socket N

Touch current (medical equipment)

Touch current (Itou)

  • Range: 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
  • Resolution: 1 µA / 0.01 mA 
  • Accuracy: ±(3 % of reading + 3 D) / ±(5 % of reading)

Ulpe (direct)

  • Range: 0 V … 299 V 
  • Resolution: 1 V 
  • Accuracy: ±(2 % of reading + 2 D)

Power (direct) (P)

  • Range: 0 W … 999 W / 1.00 kW … 3.70 kW 
  • Resolution: 1 W / 10 W 
  • Accuracy: ±(5 % of reading + 5 D) / ± 5 % of reading
  • Operating range (acc. to EN 61557-16)........... 0.010 mA … 19.99 mA

Test terminals

  • Itou: Socket L,N – P/S
  • Ulpe: Socket L – Socket PE
  • P: Socket L – Socket N

General data

Mains supply

  • Supply voltage, frequency .......................110 V / 230 V AC, 50 Hz / 60 Hz
  • Supply voltage tolerance .........................10 %
  • Max. power consumption.........................300 VA (without load on test socket)
  • Max. load………………………. ...............10 A continuous, 16 A short duration, 1.5 kW motor
  • Mains supply overvoltage category.........CAT II / 300V
  • Altitude.....................................................≤ 2000 m

Measuring categories

  • Instrument:...............................................Cat II / 300 V
  • Test socket:..............................................Cat II / 300 V
  • Plug test cable: ........................................Cat II / 300 V
  • Altitude.....................................................≤ 2000 m

Protection classifications

  • Power supply……………………… ..........Class I, mains supply, Class II, only battery supply
  • Pollution degree.......................................2
  • Degree of protection ................................IP 40
  • .................................................................IP 20 (mains test socket)
  • Case.........................................................Shock proof plastic / portable
  • Display .....................................................Colour TFT display, 4.3 inch, 480 x 272 pixels
  • Touch screen ...........................................Capacitive

Communication

  • Memory....................................................depends on microSD card size
  • RS232 interfaces .....................................2
  • USB 2.0....................................................Standard USB Type B
  • Bluetooth..................................................Class 2
  • Dimensions (w×h×d):...............................31 cm × 13 cm × 25 cm
  • Weight......................................................6.1 kg

Reference conditions

  • Reference temperature range: ................15 ˚C … 35 ˚C
  • Reference humidity range: ......................35 % … 65 % RH
  • Operation conditions
  • Working temperature range:....................0 ˚C … +40 ˚C
  • Maximum relative humidity:.....................85 % RH (0 ˚C … 40 ˚C), non-condensing
  • Storage conditions
  • Temperature range:.................................-10 ˚C … +60 ˚C
  • Maximum relative humidity:.....................90 % RH (-10 ˚C … +40 ˚C)
  • .................................................................80 % RH (40 ˚C … 60 ˚C)

Accuracies apply for 1 year in reference conditions. Temperature coefficient outside these limits is 0.2 % of measured value per ˚C plus 1 digit, otherwise noted.

Fuses: 2 x T 16 A / 250 V, 32 mm  6.3 mm / 1500 A