Seaward Apollo 400+ PATGuard Elite Kit- 5th Edition Compliant

SKU: SEAWAPOLLO400PLUSKITS1Y
  • Seaward Apollo 400+ Kits with PATGuard Elite 3 Software
  • Comprehensive range of electrical tests updated for 5th edition testing and BSEN 50699 compliant
  • Easily manage, organise and store appliance records
  • Includes QWERTY keyboard & bright HD colour display
More Info
£1,282.80 £1,069.00
In Stock - Available Next Day

Seaward Apollo 400+ PATGuard Elite Kit - 5th Edition Compliant

The Seaward Apollo 400+ PATGuard Elite Kit incoporates an improved user interface with a highly useful dedicated database search function. Now featuring an external & rechargeable battery pack, recharge in the field and reduce unnecessary downtime waiting for the tester to resume operations.

Updated to be fully compliant with the 5th edition of the IET Code of Practice, the Apollo 400+ includes functions such as:

  • Pass/Fail limit of 5mA for all protective & touch leakage tests in line with 5th edition
  • New Test sequence for Class 2 FE equipment

With intuitive and rapid PAT testing, plus storage for up to 2000 appliance records and 25 inbuilt auto sequence test (of which one is user editable), the Seaward Apollo 400+ PAT Tester is the ideal versatile, user-friendly PAT instrument ideal for professional PAT testing operatives with heavy workloads.

  • Downloadable PAT tester with inbuilt QWERTY keyboard
  • Battery powered and portable (weighing just 1.5kg)
  • Stores and downloads up to 2000 appliance records
  • Features high definition colour display
  • Transfers data remotely from field to office
  • Supplied with 25 pre-defined auto sequence tests
  • Carries out tests to ensure full compliance with the 5th Edition IET Code of Practice
  • Point to point testing for fixed appliances
  • Downloads into Seaward PATGuard 3 software
  • Supplied with UKAS calibration certificate and a 2 year warranty

IET 5th Edition and BSEN 50699 Compliant

The Seaward Apollo 400+ is fully compatible with the test limits published in both the 5th Edition IET Code of Practice, and the BSEN 50699 Recurrent Tests of Electrical Equipment standard. Simply choose the guidelines you choose to work with on the PAT tester, and the tester will compare measured results with those published, providing users with a clear pass/fail indication.

Read more about the differences between the guidance published in the 5th Edition IET Code of Practice and BSEN 50699 Recurrent Tests of Electrical Equipment, by reading our blog post here.

Seaward PATGuard 3 Elite PAT Testing Software

The recommended PC software for the Seaward Apollo 400+ PATGuard Elite Kit is designed to assist with organisation and management of your PAT Testing results. Immediately recognising a compatible tester, the software accepts download data either via USB connection or Bluetooth (Windows Bluetooth compatibility required).

Built with IET requirements as the priority, PATGuard Elite 3 and is the most comprehensive software package for Health and Safety management. Enabling users to record, store and report data from risk assessments & workplace hazard findings.

As part of the upgrade to the Apollo 400+, Seaward PATGuard 3 now incorporates Time Manager 3. This is specifically intended for companies managing off-site or remote testing staff as it provides graphical and statistical records of staff activity.

We know the importance of getting the right instrument for the job, so we now offer a "Try Before You Buy" option on many of our products to help you make a more informed buying decision. Simply give us a call or click here to find out more.

What's In The Box?

  • Seaward Apollo 400+ PAT Tester w/ standard accessories
  • Seaward PATGuard Elite 3 (1 Year License → upgradable to Infinite License)
  • Seaward Online PAT Training Course w/ Online Certificate/Exam
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 Pass Wrap Labels
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • IEC Adaptor Kit
  • FREE Seaward Apollo Custom Carry Bag
Specification

Earth Continuity

  • Test Current: +/- 200mA DC
  • Display Range: 0.01 – 19.99Ω
  • Pass Value: User Defined

Insulation Resistance

  • Test Voltage: 500V / 250VDC @ 1mA nominal
  • Display Range: 0.01MΩ - 19.99MΩ
  • Pass Value: User Defined

IEC Lead Test

  • Test voltage: 5VAC nominal
  • Test: Live / Neutral Checks for o/c, s/c and crossed

Protective Conductor Current/Load

  • Test Voltage: Supply voltage, maximum load current 16A
  • Display Ranges: 0.01mA to 19.99mA
  • Pass Value: User Defined

Touch Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Display Range: 0.00 – 3.50mA
  • Pass Value: User defined

Load Power/Current

  • Test Voltage: Supply Voltage, maximum load current 16A
  • Test Duration: Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
  • Display Range: 0.00kVA – 4.00kVA, 0.00A – 16.00A

Alternative Leakage Current

  • Test Voltages: >25VAC <50VAC
  • Display Range: 0.00mA to 19.99mA
  • Pass Value: User Defined

RCD Test

  • Test Voltage: 230V +10%, -15%
  • Test Current: 30mA / 150mA rms sinusoidal
  • Display Range: 0ms - 2000ms (30mA), 0-40ms (150mA)
  • Test method: Internal isolation to avoid tripping distribution board RCD

Power Socket Test

  • Voltage Range: 207V – 253VAC
  • Indicates configuration of voltage potential:- Line potential phase to earth, Line potential phase to neutral, Line potential neutral to earth

General

  • Memory size: 2000 records
  • Weight: 1.5kg
  • Dimensions: 230mm x 150mm x 100mm
  • Power Source: Mains or rechargeable battery pack