Chauvin Arnoux L412 Dual Channel Current Datalogger

SKU: CHAUL412
  • Versatile solution that offers two measurement channels
  • Compatible with a wide range of current sensors with automatic recognition of the connected sensor
  • High electrical safety of 600V CAT IV and 1000V CAT III
More Info
Typically ships in 3-5 working days

Chauvin Arnoux L412 Dual Channel Current Datalogger

The Chauvin Arnoux L412 Dual Channel Current Datalogger is a compact and reliable tool designed to precisely monitor and analyse electrical systems. It has two measurement channels, which offer the flexibility of measuring a wide range of single- and two-phase electrical distribution systems. When it comes to applications, the L412 is suitable for detecting intermittent electrical problems, recording correct system operating currents and resizing current transformers used for metering.

The L412 is compatible with a wide range of AC sensors and automatically recognises the connected one for seamless configuration. This ensures quick setup and accurate data capture across various measurement environments. The L412 is also reliable, whether it is used for troubleshooting, routine maintenance, or energy efficiency assessments.

Included with the L412 is the Datalogger Transfer software which makes data processing and management easy. This powerful software allows users to retrieve and visualise recorded measurements in graphical or tabular formats and export data directly to Excel for further analysis. The software also supports real-time monitoring, configuration of measurement parameters such as current range and frequency, and password protection to secure device settings.

With built-in Wi-Fi and USB communication, users can easily configure, control, and download data from the device. The L412 supports two Wi-Fi operating modes: connecting to a company’s IT network via a secure server or creating a direct link to a PC or smartphone. Its embedded web server allows remote operation via any Android or iOS web browser, displaying real-time data, recording trends, and providing full configuration access. Integration with IRD DataView Synch adds convenience by allowing secure access and review of data from anywhere in the world.

The L412 features an LCD backlit display for visible readings, a large 8 GB memory for extensive data storage, and a measurement rate of 1 per second for precise tracking. It can aggregate data for 1 to 60 minutes depending on monitoring needs and is powered by three AA batteries or USB, providing up to three days of recording without Wi-Fi. The L412 has an IP54 rating for dependable operation in demanding environments, is designed to meet the highest electrical safety standards – 600V CAT IV and 1000V CAT III – and can withstand operating temperatures ranging from -20°C to +50°C.

Note: The Chauvin Arnoux L412 is not supplied with any measurement CTs. These must be purchased separately according to your measurement requirements. Please refer to the optional accessories tab to select compatible CTs for your application.

Comparing L411, L412 and L461 Datalogers

  L411 L412 L461
Number of channels 1 2 1
Range From 0.5 to 3000 A ac Depending on sensor(s) From 10 V to 1200 Vac / 1500 Vdc
Frequency Yes
Display LCD backlit
Memory size 8 GB
Acquisition speed 1 measurement / s
Aggregation 1 to 60 min
Communication USB, WiFi, Web server, IRD server DataView Synch
Power supply 3 piles AA, or USB
Battery life 3 days recording without Wi-Fi
Shock-proof sheath Option
Dimensions 147 × 34 × 72 mm 177 × 34 × 72 mm 178 × 34 × 72 mm
Weight 340 g approx.  300 g approx. 300 g approx.
Sensor Ø100 mm / 350 mm cable length 1.2 m  - -
Operating temperature -20°C to 50°C
Protection IP 54
Electrical safety 600 V CAT IV / 1000 V CAT III 600 V CAT IV / 1000 V CAT III 600 V CAT IV / 1000 V CAT III / 1500 Vdc CAT III

Specialists In Power Quality Analysers

Watch the video above to see how we can help you find the right power quality analyser & get in touch on 0113 248 9966 or sales@test-meter.co.uk.


As a leading provider of Power Quality Analysers and Energy Loggers in the UK, we've seen a measurable rise in the demand for monitoring power usage due to the ever-increasing push to reduce carbon footprints and energy bills.

Find the best solution for your application and budget through:

  • Onsite-demo/remote consultations on request
  • 'Try Before You Buy' and hire options available
  • After-sales care that provides ongoing calibration and servicing
  • Finding the optimal software package, ensuring the correct reporting and data functionality for your needs

If you need help finding the right power quality analyser or energy logger, please get in touch on 0113 248 9966 or sales@test-meter.co.uk

part number: P01157181

Key Features

  • Dual-channel current datalogger
  • Monitors single- and two-phase electrical systems
  • Detects intermittent electrical problems and records system operating currents
  • Compatible with a wide range of AC current sensors
  • Adjustable acquisition rate: 1 measurement per second
  • Data aggregation intervals selectable from 1 to 60 minutes
  • Frequency measurement capability
  • Backlit LCD display
  • 8 GB internal memory
  • Real-time data display and trend recording
  • Dual Wi-Fi operating modes: Connection via company IT network/ Connection via company IT network
  • Embedded web server compatible with Android and iOS browsers
  • USB interface for configuration
  • Integration with IRD DataView Synch
  • Secure data viewing and management
  • Powered by 3 × AA batteries or USB connection
  • Up to 3 days of recording without Wi-Fi
  • Optional shock-proof sheath
  • IP54-rated protection
  • 600 V CAT IV / 1000 V CAT III safety rated

What's In The Box?

  • USB–micro USB cable
  • USB mains adapter
  • Data transfer and management software
  • Three AA batteries
  • Multilingual quick start guide
  • Test report
  • Multilingual operating manual
Specification
  • Number of channels: 2
  • Range: Depending on sensor(s)
  • Frequency: Yes
  • Display: LCD backlit
  • Memory size: 8 GB
  • Acquisition speed: 1 measurement / s
  • Aggregation: 1 to 60 min
  • Communication: USB, Wifi, Web server, IRD server DataView Synch
  • Power supply: 3 AA, or USB
  • Battery life: 3 days recording without Wi-Fi
  • Shock-proof sheath: Option
  • Dimensions: 177 x 34 x 72 mm
  • Weight: 300 g approx.
  • Operating temperature: -20°C to 50°C
  • Protection: IP54
  • Electrical safety: 600 V CAT IV | 1000 V CAT III