Fluke T6-1000 Electrical Tester

SKU: FLUKET61000
  • FieldSense measurement of AC voltage, AC current and frequency via jaw
  • Measure DC voltage and resistance via test leads
  • 17.8mm fixed jaw makes instrument safe and practical
More Info
In Stock - Available Next Day

"Buy a Fluke, get a FREE Fluke" promotion. Spend £150 or more on any qualified Fluke product(s) and claim a FREE Fluke gift!
[Click here to learn more] Offer is valid from 1st March to 31st August 2024.

Fluke T6-1000 Electrical Tester

The Fluke T6-1000 Electrical Tester can measure a range of electrical parameters including voltage, current, frequency, and resistance. The FieldSense true RMS AC voltage measurement is a very noteworthy feature. This function allows non-contact measurement of AC voltage from 0 to 1000V via the fixed 17.8mm fork opening. Non-contact FieldSense measurement is also available for AC current (0 to 200A) and frequency whilst contact measurement using test leads is available for AC/DC voltage (1000V) and resistance (100kΩ). Voltage and current can be measured simultaneously using the FieldSense function and all parameters benefit from high accuracy and excellent resolution.

The Fluke T6-1000 has a backlit digital display which clearly shows readings even in poor lighting conditions. It has a data hold function and can even display current and voltage readings simultaneously thanks to measurement via the jaw. Test functions are selected using the clearly labelled dial and the tester is also compatible with the Fluke TPAK magnetic hanging strip for hands-free use.

Non-contact measurement provides an additional layer of safety for the user and the Fluke T6-1000 is safety rated as Cat IV 600V and Cat III 1000V. Test leads and probes are provided as standard alongside instructions and batteries.

Fluke part number: T6-1000

Fluke T5 and T6 series Fluke Continuity, Current and Voltage Testers:

  Fluke T5-1000 Fluke T5-600 Fluke T6-600 Fluke T6-1000 Fluke T6-1000 Pro
Jaw Opening 12.9mm 12.9mm 17.8mm 17.8mm 17.8mm
Automatic Selection
Continuity Test
Visual Continuity        
FieldSense Technology    
True-rms Readings    
Sleep Mode
AC Current Range RMS 0-100A 0-100A 0-200A 0-200A 0-200A
AC Voltage Range 0-1000V 0-600V 0-600V 0-1000V 0-1000V
DC Voltage Range 0-1000V 0-600V 0-600V 0-1000V 0-1000V
DC Voltage Accuarcy 1% ±1 count 1% ±1 count ±1% + 2 counts ±1% + 2 counts ±1% + 2 counts
Frequency Range 45Hz to 65Hz      
Resistance Range 0 to 1000Ω 0 to 1000Ω 0 to 2000Ω 0 to 100kΩ 0 to 100kΩ
Display Count 1000 1000 1000 1000 1000
Dual Line Display-Simultaneous V+1, Hz      
Safety Rating 1000V CATIII/ 600V VAT IV 600V VAT IV 600V CAT III/300V CAT IV 1000V CAT III/600V CAT IV 1000V CAT III/600V CAT IV
2 Year Warranty

Key Features

  • FieldSense TRMS AC voltage: 0 to 1000V
  • FieldSense TRMS AC current: 0 to 200A
  • FieldSense frequency
  • Contact AC/DC voltage: 0 to 1000V
  • Contact resistance: 0 to 100kΩ
  • Backlit digital display
  • Simple dial operation
  • Cat III 1000V, Cat IV 600V

What's In The Box?

  • Fluke T6-1000 Electrical Tester
  • 2 x test leads
  • 4 x test probes
  • Fluke T6-1000 instruction manual
Specification
  • FieldSense AC voltage range: 0 to 1000V
  • FieldSense AC voltage resolution: 1V
  • FieldSense AC voltage accuracy: ±(3% + 3 counts)
  • FieldSense AC current range: 0 to 200A
  • FieldSense AC current resolution: 0.1A
  • FieldSense AC current accuracy: ±(3% + 3 counts)
  • FieldSense frequency range: 45Hz to 65Hz
  • FieldSense frequency resolution: 1Hz
  • FieldSense frequency accuracy” ±(1% + 2 counts)
  • AC voltage range: 0 to 1000V
  • AC voltage resolution: 1V
  • AC voltage accuracy: (1.5% + 2 counts)
  • DC voltage range: 0 to 1000V
  • DC voltage resolution: 1V
  • DC voltage accuracy: ±(1% + 2 counts)
  • Resistance range: 0 to 100kΩ
  • Resistance resolution: 1Ω
  • Resistance accuracy: ±(1% + 2 counts)
  • Safety: 600V Cat IV, 1000V Cat III
  • Dimensions: 61.1 x 259.3 x 43.8 mm
  • Jaw opening: 17.8 mm
  • Weight: 0.35 kg (0.78 lb)
  • Operating temperature: -10 °C to +50 °C (14 °F to 122 °F) 
  • Storage temperature: -30 °C to +60 °C (-22 °F to +140 °F)
  • Operating altitude: 2,000 m (6,562 feet) 
  • Storage altitude: 10,000 m (32,808 feet)
  • Relative Humidity: 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F); 0% to 75%, 30°C to 40 °C (86 °F to 104 °F); 0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
  • Battery Type and Life: 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
  • Temperature coefficient: 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)
  • Safety: IEC/EN 61010-1: Pollution Degree 2
  • Electromagnetic Environment: IEC/EN 61326-1: Portable