Megger PAT150 Contractors PAT Testing Kit

SKU: MEGGPAT150CONKIT
  • Dedicated SELV (Class III) appliance testing
  • Bond lead resistance nulling for improved measurement accuracy
  • Additional mains-powered functions for enhanced testing capability
More Info
£714.00 £595.00
Discontinued

Megger PAT150 Contractors PAT Testing Kit

The Megger PAT150 Contractors PAT Testing Kit is well suited to workplaces with low to moderate PAT testing needs where users need more than basic appliance testing, including offices, commercial premises and maintenance environments. Routine testing is simple thanks to dedicated test sequences for Class I and Class II appliances, as well as extension leads, while additional functions provide greater flexibility when checking different types of electrical equipment.

The PAT150 covers essential tests including 200mA earth continuity, insulation testing at selectable 250V or 500V and substitute leakage testing. It can also provide earth leakage, touch current and portable RCD testing when mains power is available, as well as a dedicated test for SELV (Class III) appliances. Adjustable PASS limits and configurable test durations let you tailor the testing process to your requirements, while bond lead resistance nulling helps reduce measurement errors. The PAT150 can also be used for live circuit measurements, allowing you to check mains supply, socket polarity, and AC voltage up to 300V.

Rugged rubber armour and toughened Gorilla Glass help protect the PAT150 during regular use. Its battery-powered operation also allows testing in areas where a convenient electrical supply is unavailable, while the additional mains-powered functions provide greater capability when a suitable supply is accessible. This combination makes the tester practical for professionals moving between different testing environments.

The kit also comes with a comprehensive range of accessories to support the entire PAT testing process. The IEC adaptor allows compatible appliances and leads to be connected for testing, while the PAT certificate pad provides a convenient way to record results. To help identify tested equipment, the kit includes two rolls of 500 PASS labels, 250 PASS wrap labels and 200 FAIL labels. You'll also receive 250 durable Tuff Tag Cable Wrap Labels, ideal for marking cables and leads. Everything fits neatly into the supplied test-meter kit bag, making it easy to keep your equipment organised and transport it between jobs.

PAT Testing Kit Comparison Guide

 

Small Business Kit

Contractors Kit

Landlords kit

Maintenance kit

Industrial kit

Test-Meter Kit Bag

✔

 ✔

✔

✔

x 2

PAT Register Book

✔

 ✔

✔

✔

✔

PAT Certificate Pad

✔

 ✔

✔

✔

✔

Test Meter PRO TMP989 230V 13A Socket Tester

✔

 

✔

   

IEC Cloverleaf Adaptor

   

✔

   

IEC Adaptor Kit

✔

 ✔  

✔

✔

500 Pass labels

x 2

 x 2

x 2

x 2

 x 2

250 Pass Wrap labels

✔

 ✔

x 2

x 2

x 2

200 Fail labels

✔

 ✔

✔

✔

✔

250 Tuff Tag Cable Wrap Labels

   ✔  

✔

✔

16A 110V Appliance Adaptor and Extension Lead Adaptor

     

✔

✔

PL13 230V 13A Plug Lockout & Padlock

   

✔

✔

 

16A 230V Appliance Adaptor and Extension Lead Adaptor

     

✔

✔

32A 110V Appliance Adaptor and IEC Extension Lead Adaptor

       

✔

32A 230V Appliance Adaptor and Extension Lead Adaptor

       

✔

16A & 32A 4 and 5 Pin Appliance Adaptors and IEC Extension Lead Adaptors

       

✔

Key Features

  • Dedicated test sequences for Class I, Class II and extension leads
  • Performs 200mA earth continuity testing
  • Selectable 250V and 500V insulation testing
  • Substitute leakage testing capability
  • Earth leakage, touch current and portable RCD testing when mains powered
  • Dedicated SELV (Class III) appliance testing
  • Adjustable PASS limits and configurable test durations
  • Bond lead resistance nulling for improved measurement accuracy
  • Live circuit measurements up to 300V AC
  • Checks mains supply, socket polarity and circuit voltage
  • Battery-powered operation for testing where mains power is unavailable
  • Additional mains-powered functions for enhanced testing capability
  • Durable construction with rugged rubber armour and Gorilla Glass
  • Supplied with IEC adaptor, certificate pad and test labels
  • Includes 250 Tuff Tag Cable Wrap Labels for durable cable identification
  • Complete kit supplied in a test-meter carry bag

What's In The Box?

  • Megger PAT150
  • Test-Meter Kit Bag
  • PAT Certificate Pad
  • IEC Adaptor
  • 2 x 500 PASS Labels
  • 250 PASS Wrap Labels
  • 200 FAIL Labels
  • 250 Tuff Tag Cable Wrap Labels
Specification

Environmental Conditions

  • Operating ambient: 20°C
  • Humidity: Nominal humidity

Continuity Test

  • Test voltage: Compliance Voltage: +4V dc, –0 % /+10 % (open circuit)
  • Test current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)
  • Continuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)
  • Resistance resolution: 10 mΩ
  • Display range: 0.01 to 19.99Ω
  • Continuity test nulling: up to 9.99 Ω
  • Test time: User selectable from 2 sec to 20 sec or selected during test to 180sec

Insulation Test

  • Insulation test: 250V dc –0 % /+25 % open circuit, 500V dc –0 % /+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load
  • Short circuit/charge current: < 2mA dc
  • Insulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)
  • Resolution: 0.01 MΩ
  • Display range: 0.10 MΩ to 99.99 MΩ
  • Test duration: User selectable from 2 sec to 20 sec or selected during test to 180sec

Substitute Leakage Test

  • Leakage current: Accuracy ± 5% ± 3 digits
  • Test frequency: Nominal mains frequency 50Hz
  • Test voltage: < 50V ac
  • Resolution: 0.01mA
  • Display range: 0.10 to 19.99mA
  • Test duration: User selectable from 2 sec to 5 seconds
  • Reading corrected to 230V ac.

Touch Current Test

  • Test voltage: Nominal mains 230 V ac
  • Test frequency: Nominal mains 50 Hz
  • Test accuracy: ± 5% ± 3 digits
  • Resolution: 0.01 mA
  • Display range: 0.10 to 3.99 mA
  • Test duration: User selectable from 2 sec to 5 sec

SELV Device Test

  • Test voltage: 0 to 300 V ac
  • Measurement accuracy: ± 3% ± 3 digits
  • Resolution: 0.1 V ac
  • Display range: 0.1 to 300 V ac

Extension Lead Test

Test includes Insulation and Bond tests.

  • Test voltage: 5V
  • Polarity: Lead OK, Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit

Portable RCD Test

  • Test voltage: Nominal mains 230 V
  • Test frequency: 50Hz
  • Test current accuracy: +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ± 1ms
  • Trip time resolution: 0.01ms
  • Display range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)

Mains Supply Test

  • Frequency measurement range: 50 Hz
  • Test voltage: 40 to 300V ac
  • Accuracy: ± 3% ± 3 digits
  • Resolution: 0.1Vac
  • Display range: 40 to 300V ac

Circuit Test

Carried out automatically, not available to user.

  • Test voltage: 5V
  • Test frequency: Nominal Mains 50 Hz
  • Test current: < 100mA short circuit

Safety

  • Instrument designed to IEC 61010-1: 2012
  • Test leads designed to IEC 61010-031: 2005
  • 300 volts to Earth Category II
  • Mains fuse protection to 250 volts rms ac

EMC

  • Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.

Environmental

  • Operating temperature range: 0°C to +40°C
  • Storage temperature range: -20°C to +60°C
  • Humidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C
  • Maximum altitude: 2,000m to full safety spec.
  • IP rating: IP40 (with front cover closed)

General

  • Battery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)
  • Weight (PAT150 Only): 1300g
  • Weight (Shipping): 2795g / 2975g for PAT150R
  • Dimensions: 203 x 148 x 78mm
  • Megger Part Number: 1003-064 / 1003-428 (rechargable model)

Please see our terms and conditions for full details of TM Care & Protect.

Everything you’re likely to require for the next 3 or 5 years:

✅ Annual calibrations included
No further calibration costs for either 3 or 5 years

✅ Free collection and return for annual calibration
No hidden postage costs when it’s time for calibration

✅ ‘Zero-Downtime’ for the life of your care plan
Free loan equipment should your purchase ever need sending away for repair

✅ Anti-theft protection 
Each care plan includes a SmartTrace Forensic Marking kit that acts as a deterrent for your test equipment and other tools

✅ Instrument cleaning kit
Cleaning kit included with each TM Care & Protect plan

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Ensures complete reliability, minimised downtime and peace of mind. TM Care & Protect packages include:

✅ Annual Calibration
No further calibration costs for up to 5 years.

✅ Zero Unplanned Downtime
In case of any unforeseen repairs, we provide FREE loan instruments so you can continue working.

✅ Theft Deterrent Kit
Each care plan includes a SmartTrace forensic marking kit: The UK's most powerful theft deterrent. Use on your test equipment, van and tools.

✅ No Shipping Cost
Includes collection and return deliveries when it's time for calibration.

✅ Instrument Cleaning Kit
Avoid preventable issues by keeping your test equipment clean.

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Please see our terms and conditions for full details of TM Care & Protect.