Megger PAT250 PAT Tester (Rechargeable) with Bluetooth and Certsuite

SKU: MEGGPAT250SRX
  • This handheld portable appliance tester enables quick and straightforward testing across a variety of environments
  • The Megger PAT250 PAT Tester is equipped with Certsuite PAT software, enabling professional reading and analysis of test results
  • Supplied with a range of accessories, and a Multi-country AC Mains Charger so that the it can be recharged with NiMH batteries fitted
More Info
In Stock - Available Next Day
Choose Your Free Gift

Megger PAT250 PAT Tester (Rechargeable) with Bluetooth and Certsuite

The Megger PAT250 PAT Tester with Bluetooth and Certsuite is a compact, hand-held device designed for quick and easy portable appliance testing across various settings, including offices, retail spaces, and commercial units. Its robust design, featuring a rubber-armored casing and scratch-resistant hardened glass, ensures durability and reliability, even in demanding environments. Ideal for training organizations that require efficient, high-turnover testing during intensive courses, the PAT250 is both practical and user-friendly. Battery-powered operation allows for flexible use in locations without readily available electrical supply, such as warehouses and construction sites, where safety and convenience are paramount. Fully compliant with UK and European standards for electrical safety testing, the PAT250 guarantees reliable performance and safety for users in every application.

Cersuite PAT Software

The PAT250 series comes equipped with CertSuite PAT as standard, including a one-year license (subscription required after the first year). CertSuite PAT simplifies the process of recording PAT test results and creating professional-quality test reports. It supports unlimited reports and jobs.

The Megger PAT250 is equipped for insulation testing, allowing users to measure the separation between conductive parts or conductors and the earth. This test is typically conducted at 500V DC and is designed for ease of use, with the PAT250 maintaining the required test voltage down to 0.5MΩ. Additionally, the PAT250 performs substitute leakage testing, enabling the measurement of AC leakage currents, which may differ from those obtained during DC insulation tests. This test operates at less than 40V AC and does not require a mains power supply. Beyond these capabilities, the PAT250 is also suitable for measuring protective conductor currents and touch currents, further enhancing its versatility in insulation and safety testing.

The Megger PAT250 also supports continuity testing, which ensures the proper bonding of all metal parts in Class I appliances to the protective conductor. These tests are conducted using 200mA DC in both polarities, fully complying with UK and international safety regulations. In addition to continuity testing, the PAT250 offers portable RCD (PRCD) testing, along with measurements for differential leakage (protective conductor current), touch current, and operational testing. These comprehensive capabilities make the PAT250 an indispensable tool for thorough and reliable safety testing in various environments.

PAT250SX vs PAT250SRX

The PAT250 is able to operate from both AA Alkaline or NiMH cells, with battery life typically four days. Should you opt to purchase the PAT250SRX, you will receive a multi-country AC mains charger, which allows for the PAT250 to be recharged when NiMH batteries are fitted.

Both the PAT250SX and PAT250SRX are supplied with an extensions lead adaptor, a mains plug test lead, a continuity/earth bond lead, a SELV/Mains voltage red test lead, as well as a carry case. The only difference between the two options is the AC mains charger that is supplied with the PAT250SRX, which is the rechargeable option.

Megger part number: 1016-047

Key Features

  • Offers fast and simple safety testing in all environments, including offices, shops and business units
  • Includes a 1 year licence for CertSuite PAT software
  • Can save results to the cloud and is able to produce reports quickly
  • Shows 'Pass' or 'Fail' indications with a simple tick or cross
  • Is battery powered, but a rechargeable option is also available
  • Safe 250V insulation and leakage test for surge-protected and IT equipment
  • Can conduct continuity tests up to 200mA
  • Offers substitute leakage testing
  • Mains powered and 10 mA and 30 mA portable RCD lead testing
  • Offers fast testing and report generation
  • Has a tough rubber armour with built-in front cover
  • The PAT250 has additional tests available for testing portable RCDs (PRCDs) of 10 mA and 30 mA
  • Separate tests are available for continuity, insulation, mains powered leakage testing and SELV measurements can be using the Quick Test (QT) button
  • The user is able to configure test group pass limits and test duration
  • Bond lead resistance can be nulled to reduce measurement errors
  • Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300V ac
  • Can be used for testing fixed appliances

What's In The Box?

  • Megger PAT250 PAT Tester
  • Extension Lead Adaptor
  • Mains Plug Test Lead
  • Continuity/Earth Bond Lead
  • SELV/Mains Voltage Test Lead Red x1
  • Carry Case 1005-075
  • Multi-country AC Mains Charger
Specification
  • Operating Ambient - 20°C
  • Humidity - 45% rh ± 20 points

Continuity Test

  • Test Voltage - Compliance voltage: +4V DC -0% / +30% (open circuit)
  • Test Current - Bi-directional +200mA -0% + 50mA (into Ω load)
  • Continuity Accuracy - Resistance: ± 5% ± 3 digits (0 to 19.99Ω)
  • Resolution - Resistance 10mΩ
  • Display Range - 0.01 to 19.99Ω
  • Continuity - test nulling up to 9.99Ω
  • Test Time - User selectable from 2s to 20s or selected during test to 180s

Insulation Test

  • Insulation Test - 250V DC -0% +25% open circuit, 500V DC -0% +25% open circuit, ≥ 500V 0% DC across 0.5MΩ load
  • Short Circuit/Charge Current - <2mA DC
  • Insulation Accuracy - ± 3% ± 10 digits (0 to 19.99MΩ)
  • Resolution - 0.01mA
  • Display Range - 0.10MΩ to 99.99MΩ
  • Test Duration - User selectable from 2s to 20s or selected during test to 180s

Substitute Leakage Test

  • Leakage Current - Accuracy ± 5% ± 3 digits
  • Test Frequency - Nominal mains frequency 50Hz
  • Test Voltage - <50V ac
  • Resolution - 0.01mA
  • Display Range - 0.10 to 19.99mA
  • Test Duration - 0.01mA
  • Display Range - User selectable from 2s to 5s, Reading corrected to 230V AC

Differential Leakage Current

  • Test Voltage - Nominal supply voltage 230V AC
  • Test Frequency - Nominal mains frequency 50Hz
  • Test Accuracy - ± 5% ± 3 digits ± 3 uA/A
  • Resolution - 0.01mA
  • Display Range - 0.10 to 19.99mA
  • Test Duration - User selectable from 2s to 5s

Touch Current Test

  • Test Voltage - Nominal mains 230V AC
  • Test Frequency - Nominal mains 50Hz
  • Test Accuracy - ± 5% ± 3 digits
  • Resolution - 0.01mA
  • Display Range - 0.10 to 3.99mA
  • Test Duration - User selectable from 2s to 5s

SELV Device Test

  • Test Voltage - 0 to 300V AC
  • Test Accuracy - ± 3% ± 3 digits
  • Resolution - 0.1V AC
  • Display Range - 0.1 to 300V AC

Extension Lead Test

  • Test Voltage - 5V
  • Polarity -
    Lead OK
    Live/neutral shorted
    Live/neutral reversed
    Live/neutral open circuit

Extension Portable RCD Test

  • Test Voltage - Nominal mains 230V
  • Test Frequency - 50Hz
  • Test Current Accuracy - +2% to +9% (1 x I, 5 x I)
  • Test Accuracy - Trip time ± 1% ± 1ms
  • Resolution - Trip time 0.01ms
  • Display Range - 0 to 200ms (1 x I), 0 to 40ms (5 x I)

Mains Supply Test

  • Frequency Measurement Range - 50Hz
  • Test Voltage - 40 to 300V AC
  • Test Accuracy - ± 3% ± 3 digits
  • Resolution - 0.1V AC
  • Display Range - 40 to 300V AC

Circuit Test (Carried out automatically, not available to user)

  • Test Voltage - 5V
  • Test Frequency - Nominal mains 50Hz
  • Test Current - <100mA short-circuit

Safety

  • Instrument designed to IEC 61010-1: 2010
  • Test leads designed to IEC 61010-031: 2008

PAT250

  • 300V to Earth Category II
  • Mains fuse protection to 250V rms AC

EMC

  • Designed to meet IEC 61326-1: 2012 and IEC 61326-2-2: 2005

Performance Standard

  • BS EN 50678:2020
  • BS EN 50699:2020
  • User Replaceable Fuse - 13A fused mains plug (PAT250-UK only), One F 100mA 250V 5x20 mm HBC
  • Operating Temperature - 0°C to +40°C
  • Storage Temperature - -20°C to +60°C
  • Humidity - 90% rh @ +10°C to +30°C, 75% rh @ +10°C to +60°C
  • Operating Altitude - up to 2,000m
  • IP Rating - IP40 (with front cover closed)

Mechanical

  • Battery Life - Over 1000 full Class 1 tests using 3400mAh Alkaline battery
  • Battery Type - Eight AA LR6 cells, 12V DC (Alkaline cells), 9,6V DC (NiMH cells)
  • PAT250 Weight - instrument is 1300g (45.8oz), shipping is 2795g (98.6oz)
  • PAT250SRX Weight - instrument is 1300g (45.8oz), shipping is 2975g (104.9oz)

Dimensions

  • Dimensions - Instrument and case is 203 (L) x 148 (W) x 78mm (H) (8 x 5.7 x 3.2 inches), Instrument and packaging is 456 (L) x 178 (W) x 89mm (H) (18 x 7.1 x 3.5 inches)

Please see our terms and conditions for full details of TM Care & Protect.

Everything you’re likely to require for the next 3 or 5 years:

✅ Annual calibrations included
No further calibration costs for either 3 or 5 years

✅ Free collection and return for annual calibration
No hidden postage costs when it’s time for calibration

✅ ‘Zero-Downtime’ for the life of your care plan
Free loan equipment should your purchase ever need sending away for repair

✅ Anti-theft protection 
Each care plan includes a SmartTrace Forensic Marking kit that acts as a deterrent for your test equipment and other tools

✅ Instrument cleaning kit
Cleaning kit included with each TM Care & Protect plan

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Ensures complete reliability, minimised downtime and peace of mind. TM Care & Protect packages include:

✅ Annual Calibration
No further calibration costs for up to 5 years.

✅ Zero Unplanned Downtime
In case of any unforeseen repairs, we provide FREE loan instruments so you can continue working.

✅ Theft Deterrent Kit
Each care plan includes a SmartTrace forensic marking kit: The UK's most powerful theft deterrent. Use on your test equipment, van and tools.

✅ No Shipping Cost
Includes collection and return deliveries when it's time for calibration.

✅ Instrument Cleaning Kit
Avoid preventable issues by keeping your test equipment clean.

Our hope is that TM Care & Protect will bolster our commitment to support you throughout your journey with us, providing you peace of mind from the hassles of annual servicing, potential tool theft and loss of earnings.

Please see our terms and conditions for full details of TM Care & Protect.