Chauvin Arnoux D30N AC Current Clamp Probe

SKU: CHAUD30N
  • Heavy-duty 2,400A AC Current Clamp Probe
  • Max. jaw width of 90mm
  • Transformation ratio of 3,000 / 1
More Info
Typically ships in 5-7 working days

Chauvin Arnoux D30N AC Current Clamp Probe

The Chauvin Arnoux D30N AC Current Clamp Probe is an extremely heavy-duty piece of equipment designed for non-contact measuring of alternating currents, it negates the need to open a circuit or shut off an installation. Specifically for medium currents rated 2400A AC and featuring True RMS measurement values, the transformation ratio provided by the clamp is 3000 to 1.

The intuitive shape of the D30N clamp and spring-loaded jaw, boasting a maximum width of 90mm, provides an easy method of enclosing busbars or cables (up to 64mm diameter). With a measurement range of 1 to 3600A AC, the alternating current output signal is produced via isolated 4mm female sockets and protected against voltage surges. Rated CAT IV 300V and CAT III 600V with a one year warranty, the clamp is equipped with a voltage limiter and can withstand a 20% overload on all ranges for extra user safety.

Key Features

  • Rated for 2400A AC
  • Capable of a maximum jaw opening of 90mm
  • Transformation ratio of 3000:1
  • Rugged design with sturdy grip
  • 4mm surge protected female sockets
  • Voltage limiter with 42 Vpeak included as standard
  • CAT IV 300V / CAT III 600V
  • 12 month warranty

Chauvin Arnoux part number: P01120049A

Specification

Influencing Quantity : Reference Value

  • Temperature: 23 ± 3˚C
  • Relative Humidity: 0 to 85% RH
  • Frequency of signal measure: 48 to 65Hz
  • Type of signal: Sinusoidal without DC component
  • Adjacent current-carrying conductor: None
  • Conductor position in jaws: Centred
  • External electric field: None
  • External DC magnetic field: < 40A/m
  • External AC magnetic field: None
  • Input impedance of measuring instrument: ≤ 5Ω

General Specifications

  • Transformation Ratio: 3,000 / 1
  • Measurement Range: 1 to 3,600A AC
  • Intrinsic uncertainty and phase shift:
    • 1.5%R and 1.5˚ for 150A
    • 0.75%R and 0.75˚ for 600A
    • 0.5%R and 0.5˚ for 3,000A
    • 0.5%R and 0.5˚ for 3,600A
  • Accuracy class as per IEC 61869-2 for a given load: 0.5 (5V A)
  • Influence of temperature: < 0.1% / 10˚C
  • Influence of an adjacent current-carrying conductor: 0.005A / A
  • Influence of conductor position: 1% + 0.1A
  • Protection against opening of secondary (Umax in open circuit): Yes (42 Vpeak)
  • Duration of use:
    • from 1 to 2,400 A: permanent
    • from 2,400 to 2,800 A: 15min - 30min off
    • from 2,800 to 3,400 A: 10min - 30min off
    • from 3,400 to 3,600A: 5min - 30min off
Label Type Size Download
pdf D30N AC Current Clamp Probe User Manual pdf 1.4 MB Download
pdf Chauvin Arnoux DN Series Specifications pdf 521.8 KB Download